Micro gas turbine cogeneration system with latent heat storage at the University: Part II: Part load and thermal priority mode

被引:12
|
作者
Kurata, Osamu [1 ]
Iki, Norihiko [1 ]
Matsunuma, Takayuki [1 ]
Maeda, Tetsuhiko [2 ]
Hirano, Satoshi [3 ]
Kadoguchi, Katsuhiko [4 ]
Takeuchi, Hiromi [4 ]
Yoshida, Hiro [5 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Turbomachinery Grp, Tsukuba, Ibaraki 3058564, Japan
[2] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Socioecon & Policy Study Grp, Tsukuba, Ibaraki 3058564, Japan
[3] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Thermal & Fluid Syst Grp, Tsukuba, Ibaraki 3058569, Japan
[4] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Tsukuba, Ibaraki 305, Japan
[5] Kanagawa Inst Technol, Dept Vehicle Syst Engn, Atsugi, Kanagawa 2430292, Japan
关键词
Cogeneration system; Micro gas turbine; Latent heat storage; Phase-change material; University; Energy flow; Part-load operation; Thermal priority mode; Programmable logic controller; PERFORMANCE ANALYSIS; POWER; MICROTURBINE; OPERATION;
D O I
10.1016/j.applthermaleng.2013.12.050
中图分类号
O414.1 [热力学];
学科分类号
摘要
A good cogeneration system should have high efficiency and good coordination. A micro gas turbine cogeneration system with latent heat storage was demonstrated at the University. Since there had been no cogeneration system with the latent heat storage under service condition, this system was the first demonstration and its characteristic was very important. The proper use of the latent heat storage system will save energy economically, store high energy density, reduce exhaust emissions, and save operational costs. A heat exchanger and an economizer were located in parallel downstream of a bypass dumper for exhaust gas. The latent heat storage tank was located downstream of the economizer. The bypass dumper released exhaust gas when the boiler water in the heat exchanger exceeded 90 C. It is very important to use the heat supply of hot water as much as possible. At the University, the winter term heat demand from 6 pm to 7 pm was somewhat less than that from 8 am to 6 pm in 2010. We conducted a part-load operation from 6 pm to 7 pm to observe how it would respond to the heat demand. The heat supply from the cogeneration system during this time period was controllable with the heat storage. The heat supply from the system at the lowest power setting was larger than the heat demand, and thus was uncontrollable without heat storage. In Part I [1], a fixed operating schedule of the system was planned and demonstrated at the University. Total 407 charge/discharge cycles of the latent heat storage were repeated. The energy flow test of the system shows the importance of heat release source and total system design. In Part III [2], a temperature control schedule of the system was demonstrated in winter morning using a new programmable logic controller (PLC). If the more larger latent heat storage system will be developed in the future, it will be expected greatly that the temperature of the classrooms are kept more comfortable with less energy consumptions and less CO2 emission. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 50 条
  • [11] THE PERFORMANCE OPTIMIZATION OF A GAS-TURBINE COGENERATION HEAT-PUMP FACILITY WITH THERMAL STORAGE
    VONSPAKOVSKY, MR
    CURTI, V
    BATATO, M
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1995, 117 (01): : 2 - 9
  • [12] Techno-economic analysis of a biogas-fueled micro gas turbine cogeneration system with seasonal thermal energy storage
    Zhang, Qian
    Banihabib, Reyhaneh
    Fadnes, Fredrik Skaug
    Sazon, Thor Alexis Salazar
    Ahmed, Naveed
    Assadi, Mohsen
    ENERGY CONVERSION AND MANAGEMENT, 2023, 292
  • [13] Analytical solutions and typical characteristics of part-load performances of single shaft gas turbine and its cogeneration
    Zhang, N
    Cai, RX
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (9-12) : 1323 - 1337
  • [14] Full and part load exergetic analysis of a hybrid micro gas turbine fuel cell system based on existing components
    Bakalis, Diamantis P.
    Stamatis, Anastassios G.
    ENERGY CONVERSION AND MANAGEMENT, 2012, 64 : 213 - 221
  • [15] Enhancement of the part-load thermal charging performance of a latent heat thermal energy storage unit with variable length fins at effective locations
    Kumar, Jayesh
    Singh, Pushpendra
    Kumar, Rajesh
    RENEWABLE ENERGY FOCUS, 2022, 43 : 130 - 145
  • [16] Part-load thermal efficiency enhancement in gas turbine combined cycles by exhaust gas recirculation
    Motamed, Mohammad Ali
    Genrup, Magnus
    Nord, Lars O.
    APPLIED THERMAL ENGINEERING, 2024, 244
  • [17] Start time control of micro gas turbine chp system with heat storage
    Kurata, Osamu
    Iki, Norihiko
    Matsunuma, Takayuki
    Maeda, Tetsuhiko
    Hirano, Satoshi
    Kadoguchi, Katsuhiko
    Takeuchi, Hiromi
    Yoshida, Hiro
    American Society of Mechanical Engineers, Power Division (Publication) POWER, 2011, 2 (01): : 417 - 425
  • [18] START TIME CONTROL OF MICRO GAS TURBINE CHP SYSTEM WITH HEAT STORAGE
    Kurata, Osamu
    Iki, Norihiko
    Matsunuma, Takayuki
    Maeda, Tetsuhiko
    Hirano, Satoshi
    Kadoguchi, Katsuhiko
    Takeuchi, Hiromi
    Yoshida, Hiro
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 2, 2012, : 417 - +
  • [19] PART-LOAD PERFORMANCE ANALYSIS OF PRESSURIZED MOLTEN CARBONATE FUEL CELL/MICRO-GAS TURBINE HYBRID SYSTEM USING A COMMERCIALLY AVAILABLE MICRO-GAS TURBINE
    Liu Ai-Guo
    Weng Yi-Wu
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 1, 2009, : 205 - 210
  • [20] Numerical and experimental study of heat transfer characteristics of a shell-tube latent heat storage system: Part II - Discharging process
    Xiao, X.
    Zhang, P.
    ENERGY, 2015, 80 : 177 - 189