A high-pass Body Birdcage Coil using cylindrical rods designed for a 1.5 T MRI system is presented. The operating resonant mode is investigated for optimized magnetic field homogeneity. The shielded Body Birdcage Coil is energized in the circularly polarized feed configuration. The input ports of the Body Birdcage Coil are matched (S-11 = S-22 = -19.7 dB) and isolated (S-21 = S-12 = -26.4 dB) at 64.3 MHz. The same analysis has been extended for human model loaded Body Birdcage Coil. A slight shift in the resonant frequency from 64.3 MHz to 63.5 MHz is observed for unloaded and human model loaded Birdcage Coil. The B-1(+) field distribution of human model loaded and unloaded Body Birdcage Coils are presented for dominant mode.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Recent Progress in Birdcage RF Coil Technology for MRI System
    Ahmad, Sheikh Faisal
    Kim, Young Cheol
    Choi, Ick Chang
    Kim, Hyun Deok
    DIAGNOSTICS, 2020, 10 (12)
  • [22] Open birdcage coil for head imaging at 7T
    Nikulin, Anton, V
    Vignaud, Alexandre
    Avdievich, Nikolai, I
    Berrahou, Djamel
    de Rosny, Julien
    Ourir, Abdelwaheb
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (04) : 2290 - 2300
  • [23] Circular and elliptical birdcage coil design for magnetic resonance imaging
    Chin, CL
    Smith, MB
    PROCEEDINGS OF THE IEEE 24TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 1998, : 26 - 28
  • [24] Simulations of a birdcage coil B1+ field on a human body model for designing a 3T multichannel TMS/MRI head coil array
    de Lara, Lucia I. Navarro
    Rad, Laleh Golestani
    Makarov, Sergey N.
    Stockmann, Jason
    Wald, Lawrence L.
    Nummenmaa, Aapo
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4752 - 4755
  • [25] Wireless power transfer in magnetic resonance imaging with a detuned birdcage coil
    Burmistrov, O. I.
    Olekhno, N. A.
    ST PETERSBURG POLYTECHNIC UNIVERSITY JOURNAL-PHYSICS AND MATHEMATICS, 2024, 17 (03): : 354 - 357
  • [26] Design and Implementation of Split-Leg Type Elliptical Whole-Body Birdcage RF Coil at 1.5 T MRI
    Kumar, Suchit
    Chung, Han-Jae
    Jeong, You-Jin
    Lee, Heung-Kyu
    Oh, Chang-Hyun
    APPLIED SCIENCES-BASEL, 2021, 11 (16):
  • [27] Degenerate mode birdcage volume coil for sensitivity-encoded imaging
    Lin, FH
    Kwong, KK
    Huang, IJ
    Belliveau, JW
    Wald, LL
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 1107 - 1111
  • [28] A quadrature lowpass birdcage coil for a vertical low field MRI scanner
    Giovannetti, G
    Francesconi, R
    Landini, L
    Viti, V
    Santarelli, MF
    Positano, V
    Benassi, A
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2004, 22B (01): : 1 - 6
  • [29] B1 field homogeneity and SAR calculations for the birdcage coil
    Ibrahim, TS
    Lee, R
    Baertlein, BA
    Robitaille, PML
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 609 - 619
  • [30] Challenging the Lumped Birdcage Coil Model for High-Field MRI
    Puddu, Claudio
    Fanti, Alessandro
    Curreli, Nicola
    Mazzarella, Giuseppe
    2014 LOUGHBOROUGH ANTENNAS AND PROPAGATION CONFERENCE (LAPC), 2014, : 308 - 311