Disinfection and recontamination of rigid endoscopes. Improved safety using an immersion quiver system

被引:6
|
作者
Rohrmeier, C. [1 ]
Strutz, J. [1 ]
Schneider-Brachert, W. [2 ]
机构
[1] Univ Regensburg, Klin Hals Nasen Ohren Heilkunde, D-93053 Regensburg, Germany
[2] Univ Klinikum Regensburg, Inst Klin Mikrobiol & Hyg, Regensburg, Germany
关键词
Diagnostic techniques; respiratory system; Otorhinolaryngology; Infection control; Equipment contamination; Patient safety; FLEXIBLE FIBEROPTIC LARYNGOSCOPES; IN-VITRO CONTAMINATION; STAPHYLOCOCCUS-AUREUS; TRANSMISSION; RECOMMENDATIONS; GUIDELINES; INFECTION; GERMANY; VIRUS; RISK;
D O I
10.1007/s00106-014-2873-x
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background. In Otorhinolaryngology, rigid endoscopes are used daily at a high frequency. There is no consensus for reprocessing these medical instruments. Often immersion disinfection procedures are used. The present study examined the possible risk of recontamination by this disinfection method and investigated the possibility of avoiding this risk by using a new immersion quiver system. Methods. Using coloured markers, a possible contact of the endoscope with the top edges of quivers of different diameters during endoscope removal was tested for. In addition, it was evaluated whether Staphylococcus aureus transfer is possible via this route. The same methodology was applied to a new immersion quiver system. Results. Whenever removing the rigid endoscopes from the conventional quiver, these touched the top of the quiver, regardless of its diameter. A transfer of Staphylococcus aureus from the quiver to the endoscope via this route could be detected in five out of eight attempts. During endoscope removal from the new immersion quiver system, no contact of the endoscope with the outer quiver occurred in 20 passes. In none of eight trials was a transfer of Staphylococcus aureus from previously contaminated immersion quivers to the endoscope shown; all immersion quivers were sterile after disinfection. Discussion. After conventional immersion disinfection, recontamination of rigid endoscopes by a contaminated quiver edge is possible. An immersion quiver system can resolve this risk of recontamination easily, by decontaminating not only the endoscope, but also the immersion quiver (inner quiver) itself in the disinfectant solution.
引用
收藏
页码:746 / 751
页数:6
相关论文
共 36 条
  • [21] Using an improved rule match algorithm in an expert system to detect broken driving rules for an energy-efficiency and safety relevant driving system
    Yay, Emre
    Martinez Madrid, Natividad
    Ortega Ramirez, Juan Antonio
    KNOWLEDGE-BASED AND INTELLIGENT INFORMATION & ENGINEERING SYSTEMS 18TH ANNUAL CONFERENCE, KES-2014, 2014, 35 : 127 - 136
  • [22] The efficiency of using a seismic base isolation system for a 2D concrete frame founded upon improved soft soil with rigid inclusions
    Awwad, Talal
    Donia, Modar
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2016, 15 (01) : 49 - 60
  • [23] The efficiency of using a seismic base isolation system for a 2D concrete frame founded upon improved soft soil with rigid inclusions
    Talal Awwad
    Modar Donia
    EarthquakeEngineeringandEngineeringVibration, 2016, 15 (01) : 49 - 60
  • [24] The efficiency of using a seismic base isolation system for a 2D concrete frame founded upon improved soft soil with rigid inclusions
    Talal Awwad
    Modar Donia
    Earthquake Engineering and Engineering Vibration, 2016, 15 : 49 - 60
  • [25] Automated Radiology Report Generation Using a Transformer-Template System: Improved Clinical Accuracy and an Assessment of Clinical Safety
    Abela, Brandon
    Abu-Khalaf, Jumana
    Yang, Chi-Wei Robin
    Masek, Martin
    Gupta, Ashu
    AI 2022: ADVANCES IN ARTIFICIAL INTELLIGENCE, 2022, 13728 : 530 - 543
  • [26] Evaluation of improved bi-manual endoscopic resection using a customizable 3D-printed manipulator system designed for use with standard endoscopes: a feasibility study using a porcine ex-vivo model
    Walter, Benjamin
    Krieger, Yannick S.
    Wilhelm, Dirk
    Feussner, Hubertus
    Lueth, Tim C.
    Meining, Alexander
    ENDOSCOPY INTERNATIONAL OPEN, 2021, 09 (06) : E881 - E887
  • [27] Improved Air Gap Control With Acceleration Feedforward Controller Using Time Delay for Solid Immersion Lens-Based Near-Field Storage System
    Kim, Jung-Gon
    Hwang, Hyun-Woo
    Park, Kyoung-Su
    Park, No-Cheol
    Yang, Hyunseok
    Park, Young-Pil
    Jeong, Jun
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (03) : 556 - 559
  • [28] Improved Nanogap Servo System Using an Error-Based Disturbance Observer for High-Speed in Solid Immersion Lens-Based Plasmonic Lithography
    Lim, Geon
    Kim, Taeseob
    Lee, Won-Sup
    Choi, Guk-Jong
    Park, Kyoung-Su
    Park, Young-Pil
    Yang, Hyunseok
    Park, No-Cheol
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2013, 52 (09)
  • [29] An Improved Driver Safety System based on Drunk and Drive Analyzing Architecture using Internet of Things Assisted Alcohol Identification Sensor
    Swarna, M.
    Saranya, G.
    Vanathi, A.
    Ashwini, R.
    Arunsundar, B.
    2024 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATION AND APPLIED INFORMATICS, ACCAI 2024, 2024,
  • [30] An improved approach for association rule mining using a multi-criteria decision support system: a case study in road safety
    Addi Ait-Mlouk
    Fatima Gharnati
    Tarik Agouti
    European Transport Research Review, 2017, 9