Comparison of fMRI analysis methods for heterogeneous BOLD responses in block design studies

被引:15
|
作者
Liu, Jia [1 ]
Duffy, Ben A. [1 ]
Bernal-Casas, David [1 ]
Fang, Zhongnan [1 ,2 ]
Lee, Jin Hyung [1 ,2 ,3 ,4 ]
机构
[1] Stanford Univ, Dept Neurol & Neurol Sci, 1201 Welch Rd,P206, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Neurosurg, Stanford, CA 94305 USA
关键词
Hemodynamic response; Block design; fMRI data analysis; Optogenetic fMRI; INDEPENDENT COMPONENT ANALYSIS; FUNCTIONAL MRI DATA; HEMODYNAMIC-RESPONSE; STATISTICAL-METHODS; BLIND SEPARATION; TIME-SERIES; BRAIN; MODEL; NEURONS; TRANSIENT;
D O I
10.1016/j.neuroimage.2016.12.045
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A large number of fMRI studies have shown that the temporal dynamics of evoked BOLD responses can be highly heterogeneous. Failing to model heterogeneous responses in statistical analysis can lead to significant errors in signal detection and characterization and alter the neurobiological interpretation. However, to date it is not clear that, out of a large number of options, which methods are robust against variability in the temporal dynamics of BOLD responses in block-design studies. Here, we used rodent optogenetic fMRI data with heterogeneous BOLD responses and simulations guided by experimental data as a means to investigate different analysis methods' performance against heterogeneous BOLD responses. Evaluations are carried out within the general linear model (GLM) framework and consist of standard basis sets as well as independent component analysis (ICA). Analyses show that, in the presence of heterogeneous BOLD responses, conventionally used GLM with a canonical basis set leads to considerable errors in the detection and characterization of BOLD responses. Our results suggest that the 3rd and 4th order gamma basis sets, the 7th to 9th order finite impulse response (FIR) basis sets, the 5th to 9th order B-spline basis sets, and the 2nd to 5th order Fourier basis sets are optimal for good balance between detection and characterization, while the 1st order Fourier basis set (coherence analysis) used in our earlier studies show good detection capability. ICA has mostly good detection and characterization capabilities, but detects a large volume of spurious activation with the control fMRI data.
引用
收藏
页码:390 / 408
页数:19
相关论文
共 50 条
  • [41] Comparison and Analysis of Domestic and Foreign Design Methods of Escalators
    Lai, Liping
    Wan, Chuanfeng
    Li, Yang
    EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 2501 - 2504
  • [42] Effects of meditation on neural responses to pain: A systematic review and meta-analysis of fMRI studies
    Fan, Cheng
    Wu, Mengjiao
    Liu, Hong
    Chen, Xiaolin
    Gao, Zhen
    Zhao, Xin
    Zhou, Jianhao
    Jiang, Zheng
    NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 2024, 162
  • [43] Methods for dealing with multiple outcomes in meta-analysis<bold>:</bold> a comparison between averaging effect sizes, robust variance estimation and multilevel meta-analysis
    Moeyaert, Mariola
    Ugille, Maaike
    Beretvas, S. Natasha
    Ferron, John
    Bunuan, Rommel
    Van den Noortgate, Wim
    INTERNATIONAL JOURNAL OF SOCIAL RESEARCH METHODOLOGY, 2017, 20 (06) : 559 - 572
  • [44] STUDIES IN DESIGN AND ANALYSIS OF DENTAL EXPERIMENTS .13. BALANCED INCOMPLETE BLOCK DESIGN
    VARMA, AAO
    CHILTON, NW
    KUTSCHER, AH
    JOURNAL OF DENTAL RESEARCH, 1970, 49 (05) : 1166 - &
  • [45] Comparison of enriched meshless finitevolume and elementfree Galerkin methods for the analysis of heterogeneous media
    Davoudi-Kia, Abdullah
    Fallah, N.
    ENGINEERING WITH COMPUTERS, 2018, 34 (04) : 787 - 799
  • [46] A comparison of simple robust PI design methods: Studies on a multivariable system
    Jones, RW
    Tham, MT
    SICE 2004 ANNUAL CONFERENCE, VOLS 1-3, 2004, : 2548 - 2553
  • [47] Comparison of two exploratory data analysis methods for fMRI: fuzzy clustering vs. principal component analysis
    Baumgartner, R
    Ryner, L
    Richter, W
    Summers, R
    Jarmasz, M
    Somorjai, R
    MAGNETIC RESONANCE IMAGING, 2000, 18 (01) : 89 - 94
  • [48] Design, Analysis, and Interpretation of Method-Comparison Studies
    Hanneman, Sandra K.
    AACN ADVANCED CRITICAL CARE, 2008, 19 (02) : 223 - 234
  • [49] COMPARISON OF EXTREME WAVE ANALYSIS METHODS FOR JETTY DESIGN AND MAINTENANCE
    Sulis, Andrea
    Annis, Antonio
    Cozza, Riccardo
    PROCEEDINGS OF THE 36TH IAHR WORLD CONGRESS: DELTAS OF THE FUTURE AND WHAT HAPPENS UPSTREAM, 2015, : 3778 - 3788
  • [50] ANALYSIS OF SOME CURRENT DECOMPOSITION METHODS: COMPARISON AND CASE STUDIES
    Bitoleanu, Alexandru
    Popescu, Mihaela
    Dobriceanu, Mircea
    Nastasoiu, Felicia
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2010, 55 (01): : 13 - 22