Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams

被引:2
|
作者
Rais, N. N. M. [1 ]
Bradley, D. A. [2 ,3 ]
Hashim, A. [4 ]
Isa, N. M. [4 ]
Osman, N. D. [5 ]
Ismail, I. [6 ]
Hassan, H. A. [1 ]
Noor, N. M. [1 ]
机构
[1] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Imaging, Serdang 43400, Selangor, Malaysia
[2] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[3] Sunway Univ, Ctr Biomed Phys, Jalan Univ, Petaling Jaya 46150, Malaysia
[4] Agensi Nuklear Malaysia, Secondary Stand Dosimetry Lab, Kajang 43600, Malaysia
[5] Univ Sains Malaysia, Adv Med & Dent Inst, Batas 13200, Pulau Pinang, Malaysia
[6] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Med, Serdang 43400, Selangor, Malaysia
关键词
fabricated Ge-doped silica; TLD-100; RQT beam quality;
D O I
10.1088/1361-6498/ab1c16
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 x 356 mu m(2) and 2.3 mol% cylindrical fibre (CF) of 481 mu m diameter, while the commercial fibre used is 4 mol% with core diameter of 50 mu m. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150 kV, a discernible energy-dependent response is seen, comparisons being made with that of lithium fluoride (LiF) thermoluminescence dosimeters (TLD-100). TL yield versus dose has also been investigated for x-ray doses from 2 to 40 mGy, all exhibiting linearity. Compared to TLD-100, greater sensitivity is observed for the fibres.
引用
收藏
页码:N8 / N18
页数:11
相关论文
共 50 条
  • [1] Advanced thermoluminescence dosimetric characterization of fabricated Ge-Doped optical fibres (FGDOFs) for electron beams dosimetry
    Zakaria, Z.
    Aziz, M. Z. Abdul
    Ishak, N. H.
    Suppiah, S.
    Bradley, D. A.
    Noor, N. Mohd
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [2] Assessment of Ge-doped optical fibres subjected to x-ray irradiation
    Ibrahim, S. A.
    Omar, S. S. Che
    Hashim, S.
    Mahdiraji, G. A.
    Bradley, D. A.
    Kadir, A. B.
    Isa, N. M.
    9TH NATIONAL SEMINAR ON MEDICAL PHYSICS (NSMP2014), 2014, 546
  • [3] Ge-doped optical fibres as thermoluminescence dosimeters for kilovoltage X-ray therapy irradiations
    Issa, Fatma
    Abd Latip, Nur Atiqah
    Bradley, David A.
    Nisbet, Andrew
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 834 - 837
  • [4] Fabricated Ge-doped Flat Optical Fibres: Assessing the Thermoluminescence Glow Curves for Proton Beam Irradiation
    Hassan, M. F.
    Rahman, W. N. W. A.
    Kadir, A. B. A.
    Isa, N. M.
    Tominaga, T.
    Geso, M.
    Akasaka, H.
    Bradley, D. A.
    Noor, N. M.
    4TH ELECTRONIC AND GREEN MATERIALS INTERNATIONAL CONFERENCE 2018 (EGM 2018), 2018, 2045
  • [5] Thermoluminescence Dosimetric Characteristics of Fabricated Germanium (Ge) Doped Optical Fibres for Electron Beams Dosimetry: A Preliminary Study
    Zakaria, Zabariah
    Aziz, Mohd Zahri Abdul
    Noor, Noramaliza Mohd
    SAINS MALAYSIANA, 2020, 49 (08): : 1981 - 1985
  • [6] Dosimetric characteristics of fabricated Ge-doped silica optical fibre for small-field dosimetry
    Lam, S. E.
    Bradley, D. A.
    Mahmud, R.
    Pawanchek, M.
    Rashid, H. A. Abdul
    Noor, N. Mohd
    RESULTS IN PHYSICS, 2019, 12 : 816 - 826
  • [7] Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
    Abdullah, N.
    Bradley, D. A.
    Nisbet, A.
    Zaman, Z. Kamarul
    Deraman, S. S.
    Noor, N. Mohd
    RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [8] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [9] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [10] Measurement uncertainty of the absorbed dose from fabricated Ge-doped optical fibres and nanoDot OSLD in radiotherapy electron beam dosimetry audit
    Abdullah, N.
    Noor, N. Mohd
    Zaman, Z. Kamarul
    Zahid, M. Mohammad
    RADIATION PHYSICS AND CHEMISTRY, 2025, 234