Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams

被引:2
|
作者
Rais, N. N. M. [1 ]
Bradley, D. A. [2 ,3 ]
Hashim, A. [4 ]
Isa, N. M. [4 ]
Osman, N. D. [5 ]
Ismail, I. [6 ]
Hassan, H. A. [1 ]
Noor, N. M. [1 ]
机构
[1] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Imaging, Serdang 43400, Selangor, Malaysia
[2] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[3] Sunway Univ, Ctr Biomed Phys, Jalan Univ, Petaling Jaya 46150, Malaysia
[4] Agensi Nuklear Malaysia, Secondary Stand Dosimetry Lab, Kajang 43600, Malaysia
[5] Univ Sains Malaysia, Adv Med & Dent Inst, Batas 13200, Pulau Pinang, Malaysia
[6] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Med, Serdang 43400, Selangor, Malaysia
关键词
fabricated Ge-doped silica; TLD-100; RQT beam quality;
D O I
10.1088/1361-6498/ab1c16
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 x 356 mu m(2) and 2.3 mol% cylindrical fibre (CF) of 481 mu m diameter, while the commercial fibre used is 4 mol% with core diameter of 50 mu m. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150 kV, a discernible energy-dependent response is seen, comparisons being made with that of lithium fluoride (LiF) thermoluminescence dosimeters (TLD-100). TL yield versus dose has also been investigated for x-ray doses from 2 to 40 mGy, all exhibiting linearity. Compared to TLD-100, greater sensitivity is observed for the fibres.
引用
收藏
页码:N8 / N18
页数:11
相关论文
共 50 条
  • [31] X-ray attenuation models to account for beam hardening in computed tomography
    Yang, Q.
    Fullagar, W. K.
    Myers, G. R.
    Latham, S. J.
    Varslot, T.
    Sheppard, A. P.
    Kingston, A. M.
    APPLIED OPTICS, 2020, 59 (29) : 9126 - 9136
  • [32] Beam hardening in x-ray differential phase contrast computed tomography
    Bevins, Nicholas
    Zambelli, Joseph
    Li, Ke
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [33] A computational study of x-ray emission from laser-irradiated Ge-doped foams
    Colvin, Jeffrey D.
    Fournier, Kevin B.
    May, Mark J.
    Scott, Howard A.
    PHYSICS OF PLASMAS, 2010, 17 (07)
  • [34] X-Ray Fluorescence Computed Tomography Induced by Photon, Electron, and Proton Beams
    Dunning, Chelsea A. S.
    Bazalova-Carter, Magdalena
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (12) : 2735 - 2743
  • [35] Improvement of image quality in transmission computed tomography using synchrotron monochromatic x-ray sheet beam
    Yuasa, T
    Takeda, T
    Zeniya, T
    Hasegawa, Y
    Hyodo, K
    Hiranaka, Y
    Itai, Y
    Akatsuka, T
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2367 - 2370
  • [36] Computed tomography for light materials using a monochromatic X-ray beam produced by parametric X-ray radiation
    Hayakawa, Y.
    Hayakawa, K.
    Inagaki, M.
    Kaneda, T.
    Nakao, K.
    Nogami, K.
    Sakae, T.
    Sakai, T.
    Sato, I.
    Takahashi, Y.
    Tanaka, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 230 - 236
  • [37] X-ray computed tomography for quality inspection of agricultural products: A review
    Du, Zhe
    Hu, Yongguang
    Buttar, Noman Ali
    Mahmood, Ashraf
    FOOD SCIENCE & NUTRITION, 2019, 7 (10): : 3146 - 3160
  • [38] X-RAY TUBE LIFETIME AND IMAGE QUALITY IN COMPUTED-TOMOGRAPHY
    SMITH, CB
    BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (645): : 820 - 820
  • [39] X-Ray Computed Tomography of Holographically Fabricated Three-Dimensional Photonic Crystals
    Chen, Ying-Chieh
    Geddes, Joseph B., III
    Yin, Leilei
    Wiltzius, Pierre
    Braun, Paul V.
    ADVANCED MATERIALS, 2012, 24 (21) : 2863 - 2868
  • [40] Tailor-made Ge-doped silica-glass for clinical diagnostic X-ray dosimetry
    Alyahyawi, Amjad
    Jupp, T.
    Alkhorayef, M.
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2018, 138 : 45 - 49