Advanced thermoluminescence dosimetric characterization of fabricated Ge-Doped optical fibres (FGDOFs) for electron beams dosimetry

被引:6
|
作者
Zakaria, Z. [1 ,2 ]
Aziz, M. Z. Abdul [3 ]
Ishak, N. H. [3 ]
Suppiah, S. [1 ,4 ]
Bradley, D. A. [5 ,6 ]
Noor, N. Mohd [1 ]
机构
[1] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Imaging, Serdang 43400, Selangor, Malaysia
[2] USM, AMDI, Oncol & Radiol Sci Cluster, Bertam 13200, Penang, Malaysia
[3] Univ Kuala Lumpur, UniKL, BMI, Bt 8 Jalan Sg Pusu, Gombak 53100, Selangor, Malaysia
[4] Univ Putra Malaysia, Ctr Diagnost Nucl Imaging, Serdang 4300, Selangor, Malaysia
[5] Sunway Univ, Ctr Biomed Phys, Jalan Univ, Petaling Jaya 46150, Selangor, Malaysia
[6] Univ Surrey, Ctr Nucl & Radiat Phys, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
Dose linearity; Optical fibres; Sensitivity; Thermoluminescence;
D O I
10.1016/j.radphyschem.2019.108487
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
For fabricated Ge-doped optical fibres (FGDOFs) investigation is made of a range of optical fibre thermoluminescence (TL) characteristics: sensitivity, dose linearity, dose rate dependence and fading together with exploration also made of percentage depth dose (PDD) curves for electron beams dosimetry. The fibres used were of various shapes, cross-section dimensions and germanium (Ge) concentrations. The responses of FGDOFs were compared against commercial fibres as well as that of an ionization chamber (PTW 31010 Semiflex 31010) and Gafchromie (TM) EBT3 films. All fibres were irradiated at the Royal Surrey County Hospital (UK) using 6-, 9- and 12 MeV electron energies, with 100 cm focus-to-sample distance (FSD) and 10 x 10 cm(2) field size, measurements being made up to the depth of dose maximum, Z(max) At a fixed 9 MeV electron energy, dose rates from 100 up to 600 eGy/min were used with field sizes ranging from 6 x 6 cm 2 to 25 x 25 cm(2). For PDD curves, the fibres were placed at depths from 0 cm to 6 cm, comparison being made against the ionization chamber and films. The water-to-air stopping power ratios and the fluence correction factors, P-fl were required in determining PDD curves when using the ionization chamber. TL yields against dose were highly linear (R-2 > 0.99). A low dependence on dose rate was found for all fibres. The 2.3 mol% flat fibre (FF) produced the superior performance, with the highest sensitivity, minimum TL fading for up to 3 months as well as relative difference of less than 2% for the build-up and fall-off region for PDD curves.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Thermoluminescence Dosimetric Characteristics of Fabricated Germanium (Ge) Doped Optical Fibres for Electron Beams Dosimetry: A Preliminary Study
    Zakaria, Zabariah
    Aziz, Mohd Zahri Abdul
    Noor, Noramaliza Mohd
    SAINS MALAYSIANA, 2020, 49 (08): : 1981 - 1985
  • [2] Comparison of effective atomic number, output factor, and glow curve of fabricated Ge-doped optical fibers (FGDOFs) for electron beams dosimetry
    Zakaria, Z.
    Aziz, M. Z. Abdul
    Ishak, N. H.
    Suppiah, S.
    Bradley, D. A.
    Noor, N. Mohd
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [3] Characterization of Ge-doped optical fibres for MV radiotherapy dosimetry
    Noor, Noramaliza M.
    Hussein, M.
    Kadni, T.
    Bradley, D. A.
    Nisbet, A.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 98 : 33 - 41
  • [4] Glass beads and Ge-doped optical fibres as thermoluminescence dosimeters for small field photon dosimetry
    Jafari, S. M.
    Alalawi, A. I.
    Hussein, M.
    Alsaleh, W.
    Najem, M. A.
    Hugtenburg, R. P.
    Bradley, D. A.
    Spyrou, N. M.
    Clark, C. H.
    Nisbet, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 6875 - 6889
  • [5] Establishment of Ge-doped optical fibres as thermoluminescence dosimeters for brachytherapy
    Issa, Fatma
    Rahman, A. T. Abdul
    Hugtenburg, Richard P.
    Bradley, David A.
    Nisbet, Andrew
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1158 - 1161
  • [6] Harnessing the thermoluminescence of Ge-doped silica flat-fibres for medical dosimetry
    Begurn, Mahfuza
    Rahman, A. K. M. Mizanur
    Begum, Mahbuba
    Abdul-Rashid, H. A.
    Yusoff, Z.
    Bradley, D. A.
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 270 : 170 - 176
  • [7] Dosimetric characteristics of fabricated Ge-doped silica optical fibre for small-field dosimetry
    Lam, S. E.
    Bradley, D. A.
    Mahmud, R.
    Pawanchek, M.
    Rashid, H. A. Abdul
    Noor, N. Mohd
    RESULTS IN PHYSICS, 2019, 12 : 816 - 826
  • [8] Tailored Ge-doped fibres for passive electron radiotherapy dosimetry
    Mat Nawi, Siti Nurasiah
    Abdul Sani, S. F.
    Khandaker, M. U.
    Ung, N. M.
    Almugren, K. S.
    Alkallas, F. H.
    Bradley, D. A.
    PLOS ONE, 2020, 15 (07):
  • [9] AN INVESTIGATION OF THE SUITABILITY OF GE-DOPED OPTICAL FIBRES IN MAILED THERMOLUMINESCENCE DOSIMETRY AUDITS OF RADIOTHERAPY DOSE DELIVERY
    Noor, N. Mohd
    Bradley, D.
    Nisbet, A.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S196 - S197
  • [10] Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
    Rais, N. N. M.
    Bradley, D. A.
    Hashim, A.
    Isa, N. M.
    Osman, N. D.
    Ismail, I.
    Hassan, H. A.
    Noor, N. M.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2019, 39 (03) : N8 - N18