Simulation and optimization of a broadband reflective far ultraviolet polarimeter

被引:2
|
作者
Le Gal, Maelle [1 ]
Ariste, Arturo Lopez [2 ]
Neiner, Coralie [1 ]
Pertenais, Martin [3 ]
机构
[1] Univ Paris, Sorbonne Univ, Univ PSL, CNRS,Observ Paris,LESIA, 5 Pl Jules Janssen, F-92195 Meudon, France
[2] Univ Toulouse, CNRS, CNES, IRAP, 14 Av E Berlin, F-31400 Toulouse, France
[3] Deutsch Zentrum Luft & Raumfahrt eV DLR, Inst Opt Sensor Syst, Rutherfordstr 2, D-12489 Berlin, Germany
关键词
MATRICES; COATINGS;
D O I
10.1364/AO.397984
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Traditional transmissive polarimetric methods can be used for wavelengths above 123 nm where birefringent materials transmit light and create significant birefringence. Below 123 nm, no suitable solution is known to measure the four Stokes parameters on a large wavelength range. Therefore, we study here an innovative reflective (rather than transmissive) polarimeter working in the far ultraviolet (FUV) range from 90 to 130 nm. We take advantage of the phase shift created by reflections as well as the different reflectivities for p (orthogonal perpendicular to) and s (parallel parallel to to the plane of incidence) polarizations to design an FUV polarimeter. Simulation of the analyzer and modulator using Mueller matrices coupled to polarimetric efficiencies calculations allowed optimization of reflective polarimeters for the first time, to the best of our knowledge. This opens up a new perspective for FUV polarimetry below 123 nm. (C) 2020 Optical Society of America
引用
收藏
页码:9320 / 9327
页数:8
相关论文
共 50 条
  • [21] The multichord far infrared polarimeter of the RFX experiment
    O'Gorman, M
    Zilli, E
    Giudicotti, L
    Prunty, S
    Milani, F
    Murari, A
    Boboc, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 1063 - 1066
  • [22] A Broadband Reflective Polarization Rotator
    Liu X.-M.
    Qi T.
    Gan L.
    Beijing Youdian Daxue Xuebao/Journal of Beijing University of Posts and Telecommunications, 2021, 44 (06): : 20 - 25and32
  • [23] Optimization analysis of a Stokes polarimeter for broadband liquid crystal variable retarders under the optimal objective function
    Chang, Lingying
    Li, Jiayi
    Zhang, Youbiao
    Yin, Yuping
    Liu, Jingyi
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2024, 41 (04) : 606 - 614
  • [24] Two dimensional simulation of Far Ultraviolet Spectroscopic Explorer (FUSE) spectra
    Sahnow, DJ
    SPACE TELESCOPES AND INSTRUMENTS V, PTS 1-2, 1998, 3356 : 1011 - 1017
  • [25] DEFORMED ELLIPSOIDAL GRATINGS FOR FAR-ULTRAVIOLET SPECTROGRAPHS - ANALYTIC OPTIMIZATION
    CONTENT, D
    NAMIOKA, T
    APPLIED OPTICS, 1993, 32 (25): : 4881 - 4889
  • [26] ULTRAVIOLET SPECTROMETER AND POLARIMETER FOR THE SOLAR MAXIMUM MISSION
    MILLER, MS
    CARUSO, AJ
    WOODGATE, BE
    STERK, AA
    APPLIED OPTICS, 1981, 20 (21) : 3805 - 3814
  • [27] ULTRAVIOLET SPECTROMETER AND POLARIMETER ON THE SOLAR MAXIMUM MISSION
    WOODGATE, BE
    TANDBERGHANSSEN, EA
    BRUNER, EC
    BECKERS, JM
    BRANDT, JC
    HENZE, W
    HYDER, CL
    KALET, MW
    KENNY, PJ
    KNOX, ED
    MICHALITSIANOS, AG
    REHSE, R
    SHINE, RA
    TINSLEY, HD
    SOLAR PHYSICS, 1980, 65 (01) : 73 - 90
  • [28] Development of a polarimeter for magnetic field measurements in the ultraviolet
    West, EA
    Porter, JG
    Davis, JM
    Gary, GA
    Adams, M
    POLARIZATION ANALYSIS, MEASUREMENT, AND REMOTE SENSING IV, 2002, 4481 : 109 - 117
  • [29] Study on spectral broadband aberration-corrected imaging spectrometer for far-ultraviolet waveband
    Yu, Lei
    Wang, Shurong
    Qu, Yi
    Lin, Guanyu
    OPTICAL ENGINEERING, 2011, 50 (06)
  • [30] A far ultraviolet-C light technology is effective for decontamination of items in proximity to sinks and is enhanced by a far UV-C reflective surface
    Kaple, Claire E.
    Memic, Samir
    Cadnum, Jennifer L.
    Varghese, Martin Mathew
    Hebrink, Timothy J.
    Donskey, Curtis J.
    INFECTION CONTROL & HOSPITAL EPIDEMIOLOGY, 2024, 45 (11) : 1319 - 1324