Dose variations with varying calculation grid size in head and neck IMRT

被引:52
|
作者
Chung, Heeteak [1 ]
Jin, Hosang
Palta, Jatinder
Suh, Tae-Suk
Kim, Siyong
机构
[1] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 19期
关键词
D O I
10.1088/0031-9155/51/19/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ever since the advent and development of treatment planning systems, the uncertainty associated with calculation grid size has been an issue. Even to this day, with highly sophisticated 3D conformal and intensity-modulated radiation therapy (IMRT) treatment planning systems (TPS), dose uncertainty due to grid size is still a concern. A phantom simulating head and neck treatment was prepared from two semi-cylindrical solid water slabs and a radiochromic film was inserted between the two slabs for measurement. Plans were generated for a 5400 cGy prescribed dose using Philips Pinnacle(3) TPS for two targets, one shallow (similar to 0.5 cm depth) and one deep (similar to 6 cm depth). Calculation grid sizes of 1.5, 2, 3 and 4 mm were considered. Three clinical cases were also evaluated. The dose differences for the varying grid sizes ( 2 mm, 3 mm and 4 mm from 1.5 mm) in the phantom study were 126 cGy (2.3% of the 5400 cGy dose prescription), 248.2 cGy ( 4.6% of the 5400 cGy dose prescription) and 301.8 cGy (5.6% of the 5400 cGy dose prescription), respectively for the shallow target case. It was found that the dose could be varied to about 100 cGy ( 1.9% of the 5400 cGy dose prescription), 148.9 cGy ( 2.8% of the 5400 cGy dose prescription) and 202.9 cGy ( 3.8% of the 5400 cGy dose prescription) for 2 mm, 3 mm and 4 mm grid sizes, respectively, simply by shifting the calculation grid origin. Dose difference with a different range of the relative dose gradient was evaluated and we found that the relative dose difference increased with an increase in the range of the relative dose gradient. When comparing varying calculation grid sizes and measurements, the variation of the dose difference histogram was insignificant, but a local effect was observed in the dose difference map. Similar results were observed in the case of the deep target and the three clinical cases also showed results comparable to those from the phantom study.
引用
收藏
页码:4841 / 4856
页数:16
相关论文
共 50 条
  • [31] Reduction of laryngeal dose with modified IMRT technique in head and neck tumors
    Both, S.
    Das, I.
    Bar Ad, V.
    Zhou, X.
    Jacobs, B.
    Quon, H.
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 : S73 - S73
  • [32] In vivo dose verification of IMRT treated head and neck cancer patients
    Engström, PE
    Haraldsson, P
    Landberg, T
    Hansen, HS
    Engelholm, SA
    Nyström, H
    ACTA ONCOLOGICA, 2005, 44 (06) : 572 - 578
  • [33] A TLD and film dosimetry study of surface dose for head and neck IMRT
    Mitchell, M. J.
    Ramsey, C. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S714 - S715
  • [34] The impact of dental metal artifacts on head and neck IMRT dose distributions
    Kim, Yusung
    Tome, Wolfgang A.
    Bal, Matthieu
    McNutt, Todd R.
    Spies, Lothar
    RADIOTHERAPY AND ONCOLOGY, 2006, 79 (02) : 198 - 202
  • [36] IMRT head and neck phantom irradiations: Correlation of results with institution size
    Molineu, A
    Hernandez, N
    Alvarez, P
    Followill, D
    Ibbott, G
    MEDICAL PHYSICS, 2005, 32 (06) : 1983 - 1984
  • [37] IMRT IN HEAD AND NECK CANCER
    Pedro Olive, A.
    Lainez, C.
    Vila, A.
    Moya, L. M.
    Julia, J. C.
    Artola, N.
    Sanchez-Reyes, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S257 - S257
  • [38] IMRT for head and neck cancer
    Pawlicki, T
    MEDICAL PHYSICS, 2005, 32 (06) : 2067 - 2068
  • [39] Adaptive head and neck IMRT
    Garcia, R.
    Bodez, V.
    Khamphan, C.
    Jaegle, E.
    Alfonsi, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 : S47 - S47
  • [40] Comparative Analysis of Surface Dose Measurements Using MOSFET Detector and Dose Predicted by Eclipse - AAA with Varying Dose Calculation Grid Size
    Badkul, R.
    Nejaiman, S.
    Pokhrel, D.
    Jiang, H.
    Kumar, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3377 - 3377