Fusion Technique Using Three-Dimensional Digital Subtraction Angiography in the Evaluation of Complex Cerebral and Spinal Vascular Malformations

被引:10
|
作者
Fukuda, Kenji
Higashi, Toshio [1 ]
Okawa, Masakazu
Iwaasa, Mitsutoshi
Abe, Hiroshi
Inoue, Tooru
机构
[1] Fukuoka Univ Hosp, Dept Neurosurg, Fukuoka, Japan
关键词
Arteriovenous fistula; Arteriovenous malformation; Fusion technique; Three dimensional digital subtraction angiography; DURAL ARTERIOVENOUS-FISTULAS; TIME-OF-FLIGHT; ROTATIONAL ANGIOGRAPHY; TOMOGRAPHY ANGIOGRAPHY; INTRACRANIAL ANEURYSMS; COMPUTED-TOMOGRAPHY; RECONSTRUCTION; DIAGNOSIS; LESIONS;
D O I
10.1016/j.wneu.2015.08.075
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The authors introduce a new fusion technique using 2 three-dimensional digital subtraction angiography images acquired by a flat-panel detector angiographic system to understand the detailed angioarchitecture of complex cerebral and spinal vascular malformations. METHODS: Eleven consecutive cases of arteriovenous fistula or arteriovenous malformation with lesions that involved 2 major vessels (i.e., internalcarotid arteries, external carotid arteries, vertebral arteries, or spinal arteries) were included. Three-dimensional rotational angiography was performed in each affected vessel after conventional cerebral or spinal angiography. Subsequently, the 2 three-dimensional digital subtraction angiography images were fused. RESULTS: The fused images provided the accurate three-dimensional angioarchitecture of complex vascular malformations clearly with high spatial resolution. In particular, the relationship between the nidus/fistulous point, the feeding arteries from each major vessel, and the draining veins could be easily delineated from different directions and multiple angles. Surgical or endovascular treatment was performed in all cases based on the information from these fused three-dimensional images. CONCLUSIONS: A fusion technique using two three-dimensional digital subtraction angiography is beneficial for preoperative planning and successful treatment in cases of complex cerebral and spinal vascular malformations.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 50 条
  • [21] Preoperative imaging of cervical spine hemangioblastomas using three-dimensional fusion digital subtraction angiography - Report of two cases
    Sciubba, Daniel M.
    Mavinkurve, Gaurav G.
    Gailloud, Philippe
    Garonzik, Ira M.
    Recinos, Pablo F.
    McGirt, Matthew J.
    Woodworth, Graeme F.
    Witham, Timothy
    Khavkin, Yevgeniv
    Gokaslan, Ziya L.
    Wolinsky, Jean-Paul
    JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (01) : 96 - 100
  • [22] Three-dimensional angiography using rotational digital subtraction angiography: Usefulness in transarterial embolization of hepatic tumors
    Tanigawa, N
    Komemushi, A
    Kojima, H
    Kariya, S
    Sawada, S
    ACTA RADIOLOGICA, 2004, 45 (06) : 602 - 607
  • [23] Three-dimensional reconstructed images of renal arteries using rotational digital subtraction angiography
    Endoh, H
    Shimizu, T
    Kodama, Y
    Miyasaka, K
    RADIOLOGY, 2001, 221 : 185 - 185
  • [24] Use of three-dimensional-three-dimensional digital subtraction angiography spin fusion protocol for complex aortoiliac endovascular interventions
    Skripochnik, Edvard
    D'Ambrosio, Nicole
    Crawford, William E.
    Loh, Shang A.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2021, 7 (02): : 339 - 342
  • [25] Screening of spinal vascular malformations by magnetic resonance angiography using routine three-dimensional fast spin echo sequences
    Gelbert, F
    Guichard, JP
    Sarrazin, JL
    Houdart, E
    Reizine, D
    Cordoliani, YS
    Merland, JJ
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1997, 3 (05): : 441 - 446
  • [26] Relationship between Injection Rate and Contrast Enhancement on Three-dimensional Digital Subtraction Angiography of the Cerebral Arteries
    Takagi, Satoshi
    Hanasaki, Naoyuki
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2018, 102 (01):
  • [27] Pancreas allografts: Comparison of three-dimensional rotational angiography with standard digital subtraction angiography
    Bozlar, Ugur
    Brayman, Kenneth L.
    Hagspiel, Klaus D.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (02) : 239 - 244
  • [28] Utilization of three-dimensional rotational angiography in the evaluation and endovascular treatment of cerebral aneurysms and arteriovenous malformations
    Klucznik, RP
    Mawad, ME
    RADIOLOGY, 1999, 213P : 276 - 276
  • [29] Three-dimensional dynamic magnetic resonance angiography for the evaluation of radiosurgically treated cerebral arteriovenous malformations
    Gauvrit, JY
    Oppenheim, C
    Nataf, F
    Naggara, O
    Trystram, D
    Munier, T
    Fredy, D
    Pruvo, JP
    Roux, FX
    Leclerc, X
    Meder, JF
    EUROPEAN RADIOLOGY, 2006, 16 (03) : 583 - 591
  • [30] Three-dimensional dynamic magnetic resonance angiography for the evaluation of radiosurgically treated cerebral arteriovenous malformations
    Jean-Yves Gauvrit
    Catherine Oppenheim
    Francois Nataf
    Olivier Naggara
    Denis Trystram
    Thierry Munier
    Daniel Fredy
    Jean-Pierre Pruvo
    François-Xavier Roux
    Xavier Leclerc
    Jean-François Meder
    European Radiology, 2006, 16 : 583 - 591