Pancreas allografts: Comparison of three-dimensional rotational angiography with standard digital subtraction angiography

被引:4
|
作者
Bozlar, Ugur [1 ,3 ]
Brayman, Kenneth L. [2 ]
Hagspiel, Klaus D. [1 ]
机构
[1] Univ Virginia, Hlth Syst, Dept Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Hlth Syst, Dept Surg, Charlottesville, VA 22908 USA
[3] Gulhane Mil Med Acad, Ankara, Turkey
关键词
D O I
10.1016/j.jvir.2007.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To define the role of three-dimensional (3D) rotational angiography (RA) for the evaluation of pancreas allografts and compare 3D RA to standard digital subtraction anglography (DSA). MATERIALS AND METHODS: DSA and 3D RA were performed in patients with vascular abnormalities diagnosed on contrast medium-enhanced magnetic resonance (MR) angiography. Patency of the allograft vasculature, confidence in the ability to make a therapeutic decision, and value of the study for definition of the optimal projection for an intervention was assessed on a graded scale. RESULTS: Seventeen standard DSA projections (mean, 3.4; range, 2-6) and 10 3D RA images (mean, 2; range, 1-3) were obtained in five patients. An average iodinated contrast agent dose of 14.4 mL (range, 8-22 mL) was administered for DSA. An average CO, dose of 54 mL (range, 0-120 mL) was administered for 3D RA. Five 3D RA procedures were timed for the arterial phase and five were timed for the arterial and venous phases. Average contrast agent doses were 17.6 mL (range, 11-22 mL) for arterial 3D RA and 24.4 mL (range, 16-34 mL) for arterial- and venous-phase 3D RA. Of 68 vascular segments available for direct comparison of patency, complete concordance was present in 96%. There was no difference in the reviewers' diagnostic confidence (10 +/- 0 for both techniques). Three-dimensional RA was considered significantly superior for planning the optimal projection for intervention (10 +/- 0 for 3D RA vs 7.2 +/- 1.6 for DSA; P =.0052). CONCLUSIONS: Three-dimensional RA of pancreatic allografts is feasible and does not differ in accuracy from conventional DSA. It provides similar reviewer confidence in the ability to make an accurate treatment decision, but its key advantage is its superior ability to define the optimal projection for planned endovascular interventions.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 50 条
  • [1] Comparison of three-dimensional rotational angiography and digital subtraction angiography for the evaluation of the liver transplants
    Housseini, Ahmed M.
    Bozlar, Ugur
    Schmitt, Timothy M.
    Bonatti, Hugo
    Arslan, Bulent
    Turba, Ulku C.
    Khalil, Tarek H.
    Hagspiel, Klaus D.
    CLINICAL IMAGING, 2009, 33 (02) : 102 - 109
  • [2] Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms
    Hochmuth, A
    Spetzger, U
    Schumacher, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (07) : 1199 - 1205
  • [3] Digital Subtraction CT Angiography for Detection of Intracranial Aneurysms: Comparison with Three-dimensional Digital Subtraction Angiography
    Lu, Li
    Zhang, Long Jiang
    Poon, Colin S.
    Wu, Sheng Yong
    Zhou, Chang Sheng
    Luo, Song
    Wang, Mei
    Lu, Guang Ming
    RADIOLOGY, 2012, 262 (02) : 605 - 612
  • [4] Three-dimensional volume rendering digital subtraction angiography in comparison with two-dimensional digital subtraction angiography and rotational angiography for detecting aneurysms and their morphological properties in patients with subarachnoid hemorrhage
    Kucukay, Fahrettin
    Okten, R. Sarper
    Tekiner, Ayhan
    Dagli, Mustafa
    Gocek, Cevdet
    Bayar, Mehmet Akif
    Cumhur, Turhan
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2794 - 2800
  • [5] Three-dimensional angiography using rotational digital subtraction angiography: Usefulness in transarterial embolization of hepatic tumors
    Tanigawa, N
    Komemushi, A
    Kojima, H
    Kariya, S
    Sawada, S
    ACTA RADIOLOGICA, 2004, 45 (06) : 602 - 607
  • [6] Preoperative evaluation of intracranial aneurysms: Comparison of three-dimensional digital subtraction angiography and conventional two-dimensional digital subtraction angiography
    Yoon, W
    Seo, J
    Kim, JK
    Kim, T
    Park, J
    Kang, H
    RADIOLOGY, 2002, 225 : 521 - 521
  • [7] Rotational digital subtraction carotid angiography: Technique and comparison with static digital subtraction angiography
    Bosanac, Z
    Miller, RJ
    Jain, M
    CLINICAL RADIOLOGY, 1998, 53 (09) : 682 - 687
  • [8] Rotational digital subtraction carotid angiography: Technique and comparison with static digital subtraction angiography
    Bosanac, ZB
    Miller, R
    RADIOLOGY, 1998, 209P : 278 - 279
  • [9] Three-dimensional reconstructed images of renal arteries using rotational digital subtraction angiography
    Endoh, H
    Shimizu, T
    Kodama, Y
    Miyasaka, K
    RADIOLOGY, 2001, 221 : 185 - 185
  • [10] Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms
    U. Missler
    C. Hundt
    M. Wiesmann
    T. Mayer
    H. Brückmann
    European Radiology, 2000, 10 : 564 - 568