Accuracy of the Electronic Health Record: Patient Height

被引:8
|
作者
Jurecki, Matthew C. [1 ]
Chatburn, Robert L. [1 ]
Sasidhar, Madhu [1 ]
机构
[1] Cleveland Clin, Resp Inst, Cleveland, OH 44195 USA
关键词
mechanical ventilation; electronic medical record; ideal body weight; predicted height; RESPIRATORY-DISTRESS-SYNDROME; ACUTE LUNG INJURY; PROTECTIVE VENTILATION; TIDAL VOLUME; ULNA LENGTH; ADULTS;
D O I
10.4187/respcare.04018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Protective lung ventilation requires calculating predicted body weight (BW) from height. Thus, inaccuracy of height data in the electronic health record (EHR) is a risk factor for ventilator-induced lung injury. Charted height data often have uncertain accuracy. Study purposes were (1) to evaluate the difference between patient height charted in the EHR and predicted height (PH) from ulnar length and (2) to determine how the height data source affects predicted BW and the resulting values for protective tidal volume (V-T). METHODS: Subject height data from the EHR were collected from several ICUs. Simultaneous ulnar data were collected by measuring ulnar length (cm): male PH (cm) = 79.2 +/- 3.60 x ulnar length; female PH = 95.6 +/- 2.77 x ulnar length. For each subject, BW (kg) was calculated from height charted in EHR and from predicted height: male BW = 50 +/- 0.91 x (height - 152.4); female BW = 45.5 +/- 0.91 x (height - 152.4). Then VT was calculated as 8 mL/kg BW. Bland-Altman analysis of height and VT differences (charted - predicted) determined the limits of agreement. RESULTS: For white males (n = 27) the mean (SD) height from EHR was 177 (7.5); predicted height was 178 (6.9). The limits of agreement for height in males were -18.5 and 17.8 cm. The limits of agreement for females were -23.1 and 21.3 cm. The limits of agreement for VT in males were -1.8 and 1.8 mL/kg. The limits of agreement for VT in females were -3.0 and 2.9 mL/kg. CONCLUSIONS: For overall populations, mean height calculated from values charted in the EHR is similar to that estimated from ulnar length. However, for individuals, differences in height between the 2 sources can be large, leading to large differences in predicted BW and resultant VT set in terms of mL/kg.
引用
收藏
页码:1715 / 1719
页数:5
相关论文
共 50 条
  • [31] The Rigorous Work of Evaluating Consistency and Accuracy in Electronic Health Record Data
    Singh, Karandeep
    Woodward, Maria A.
    JAMA OPHTHALMOLOGY, 2021, 139 (08) : 894 - 895
  • [32] The Impact of Documentation Workflow on the Accuracy of the Coded Diagnoses in the Electronic Health Record
    Hwang, Thomas S.
    Thomas, Merina
    Hribar, Michelle
    Chen, Aiyin
    White, Elizabeth
    OPHTHALMOLOGY SCIENCE, 2024, 4 (01):
  • [33] Navigating electronic health record accuracy by examination of sex incongruent conditions
    Cai, Ling
    Deberardinis, Ralph J.
    Zhan, Xiaowei
    Xiao, Guanghua
    Xie, Yang
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2024, 31 (12)
  • [34] TRANSITION TO ELECTRONIC HEALTH RECORDS The importance of patient involvement in implementing electronic health record systems
    Kusumo, Windu
    BMJ-BRITISH MEDICAL JOURNAL, 2016, 354 : i5035
  • [35] Is Patient Confidentiality Compromised With the Electronic Health Record? A Position Paper
    Wallace, Ilse M.
    CIN-COMPUTERS INFORMATICS NURSING, 2015, 33 (02) : 58 - 62
  • [36] Clinician documentation of patient centered care in the electronic health record
    Jorie M. Butler
    Bryan Gibson
    Olga V. Patterson
    Laura J. Damschroder
    Corrinne H. Halls
    Daniel W. Denhalter
    Matthew H. Samore
    Haojia Li
    Yue Zhang
    Scott L. DuVall
    BMC Medical Informatics and Decision Making, 22
  • [37] Is electronic health record use associated with patient satisfaction in hospitals?
    Kazley, Abby Swanson
    Diana, Mark L.
    Ford, Eric W.
    Menachemi, Nir
    HEALTH CARE MANAGEMENT REVIEW, 2012, 37 (01) : 23 - 30
  • [38] The electronic health record: An essential tool for advancing patient safety
    Malloch, Kathy
    NURSING OUTLOOK, 2007, 55 (03) : 159 - 161
  • [39] An electronic patient mental health record for corrections: Design & use
    Alexander, V
    Claussen, HB
    TOWARD AN ELECTRONIC PATIENT RECORD '97 - CONFERENCE AND EXPOSITION, PROCEEDINGS, VOLS 1-3, 1997, : B250 - B252
  • [40] The electronic patient record as a guarantor of personalised mental health care
    Mooney, M
    Barry, S
    Draper, R
    MEDINFO '98 - 9TH WORLD CONGRESS ON MEDICAL INFORMATICS, PTS 1 AND 2, 1998, 52 : 14 - 17