Accuracy of the Electronic Health Record: Patient Height

被引:8
|
作者
Jurecki, Matthew C. [1 ]
Chatburn, Robert L. [1 ]
Sasidhar, Madhu [1 ]
机构
[1] Cleveland Clin, Resp Inst, Cleveland, OH 44195 USA
关键词
mechanical ventilation; electronic medical record; ideal body weight; predicted height; RESPIRATORY-DISTRESS-SYNDROME; ACUTE LUNG INJURY; PROTECTIVE VENTILATION; TIDAL VOLUME; ULNA LENGTH; ADULTS;
D O I
10.4187/respcare.04018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Protective lung ventilation requires calculating predicted body weight (BW) from height. Thus, inaccuracy of height data in the electronic health record (EHR) is a risk factor for ventilator-induced lung injury. Charted height data often have uncertain accuracy. Study purposes were (1) to evaluate the difference between patient height charted in the EHR and predicted height (PH) from ulnar length and (2) to determine how the height data source affects predicted BW and the resulting values for protective tidal volume (V-T). METHODS: Subject height data from the EHR were collected from several ICUs. Simultaneous ulnar data were collected by measuring ulnar length (cm): male PH (cm) = 79.2 +/- 3.60 x ulnar length; female PH = 95.6 +/- 2.77 x ulnar length. For each subject, BW (kg) was calculated from height charted in EHR and from predicted height: male BW = 50 +/- 0.91 x (height - 152.4); female BW = 45.5 +/- 0.91 x (height - 152.4). Then VT was calculated as 8 mL/kg BW. Bland-Altman analysis of height and VT differences (charted - predicted) determined the limits of agreement. RESULTS: For white males (n = 27) the mean (SD) height from EHR was 177 (7.5); predicted height was 178 (6.9). The limits of agreement for height in males were -18.5 and 17.8 cm. The limits of agreement for females were -23.1 and 21.3 cm. The limits of agreement for VT in males were -1.8 and 1.8 mL/kg. The limits of agreement for VT in females were -3.0 and 2.9 mL/kg. CONCLUSIONS: For overall populations, mean height calculated from values charted in the EHR is similar to that estimated from ulnar length. However, for individuals, differences in height between the 2 sources can be large, leading to large differences in predicted BW and resultant VT set in terms of mL/kg.
引用
收藏
页码:1715 / 1719
页数:5
相关论文
共 50 条
  • [21] Patient Opportunities in the Estonian Electronic Health Record System
    Tiik, Madis
    Ross, Peeter
    MEDICAL AND CARE COMPUNETICS 6, 2010, 156 : 171 - 177
  • [22] Clinical Education and the Electronic Health Record The Flipped Patient
    Chi, Jeffrey
    Verghese, Abraham
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (22): : 2331 - 2332
  • [23] Ethical Implications of the Electronic Health Record: In the Service of the Patient
    Lois Snyder Sulmasy
    Ana María López
    Carrie A. Horwitch
    Journal of General Internal Medicine, 2017, 32 : 935 - 939
  • [24] How to Represent the Patient Voice in the Electronic Health Record?
    Silsand, Line
    Severinsen, Gro Hilde
    Berntsen, Gro R.
    Steinsbekk, Aslak
    CARING IS SHARING-EXPLOITING THE VALUE IN DATA FOR HEALTH AND INNOVATION-PROCEEDINGS OF MIE 2023, 2023, 302 : 187 - 191
  • [25] Electronic Health Record Use and Patient-Centredness
    Archibald, Douglas
    Viner, Gary
    Shah, Lisa
    Kushniruk, Andre
    Santos, Laura
    Noel, Kendall
    Motamedi, Farhad
    ANNALS OF FAMILY MEDICINE, 2024, 22
  • [26] Ethical Implications of the Electronic Health Record: In the Service of the Patient
    Sulmasy, Lois Snyder
    Lopez, Ana Maria
    Horwitch, Carrie A.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2017, 32 (08) : 935 - 939
  • [27] Patient First - A patient sensitivity tool for an electronic health record implementation
    Wolf, Debra M.
    Hartman, Loraine M.
    Larue, Elizabeth M.
    Arndt, Iris
    CIN-COMPUTERS INFORMATICS NURSING, 2007, 25 (02) : 112 - 117
  • [28] Improving electronic health record (EHR) accuracy and increasing compliance with health maintenance clinical guidelines through patient access and input
    Staroselsky, M
    Volk, L
    Tsurikova, R
    Pizziferri, L
    Wald, J
    Bates, DW
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2005, 20 : 100 - 100
  • [29] Improving electronic health record (EHR) accuracy and increasing compliance with health maintenance clinical guidelines through patient access and input
    Staroselsky, Maria
    Volk, Lynn A.
    Tsurikova, Ruslana
    Pizziferri, Lisa
    Lippincott, Margaret
    Wald, Jonathan
    Bates, David W.
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2006, 75 (10-11) : 693 - 700
  • [30] Patient Coauthored History Could Improve Health Record Accuracy
    Warner, Michael John
    JAMA OPHTHALMOLOGY, 2017, 135 (07) : 818 - 818