LOW NOISE MEASUREMENT OF PHOTOCURRENT FOR CONTINUOUS GLUCOSE MONITORING Low Noise Measurement System Enables Continuous Monitoring of Glucose in Subcutaneous Interstitial Fluid

被引:0
|
作者
Cooley, Daniel W. [1 ]
Andersen, David R. [1 ,2 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, 132 IATL, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Phys, Iowa City, IA USA
关键词
Continuous glucose monitoring; IR photodiode; Transimpedance amplifier;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a data acquisition unit (DAU) for continuous, low noise measurement of glucose concentration in subcutaneous interstitial fluid (ISF). The system is comprised of a glucose sensor (Olesberg, 2006), op-amps for signal conditioning, and delta-sigma (Delta-Sigma) ADCs. The glucose sensor has two IR LEDs which emit light with wavelength of 2.2 to 2.4 mu m where there are peaks in the glucose absorption spectrum. The IR light propagates through a glass fluid chamber containing interstitial fluid and a linearly variable bandpass filter before impinging on a 32 channel photodiode array. The center frequency of the filter varies along one dimension of the filter, so that each photodiode is sensitive to equally spaced portions of the glucose absorption spectrum. Transimpedance amplifiers (TIAs) convert the photocurrents into voltages which are sampled by ADCs. We developed a noise model which predicts the noise characteristics of the system. We use low noise metal film resistors to verify the DAU noise characteristics. Non-ideal characteristics such as limited photocurrent and low photodiode shunt resistance increase difficulty of obtaining low noise measurements. We demonstrate that the DAU provides low noise (41.7 dB SNR) photocurrent measurements and is suitable for use in a continuous glucose monitoring system.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [21] Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring
    Freckmann, Guido
    Link, Manuela
    Pleus, Stefan
    Westhoff, Antje
    Kamecke, Ulrike
    Haug, Cornelia
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (08) : 541 - 549
  • [22] Accuracy of a subcutaneous continuous glucose monitoring system in critically ill patients
    Rijkenberg, S.
    van Steen, S. C. J.
    DeVries, J. H.
    van der Voort, P. H. J.
    DIABETOLOGIA, 2016, 59 : S412 - S413
  • [23] Microdialysis system for continuous glucose monitoring
    Steinkuhl, R
    Sundermeier, C
    Hinkers, H
    Dumschat, C
    Cammann, K
    Knoll, M
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) : 19 - 24
  • [24] Eversense Continuous Glucose Monitoring System
    Crowner, Jamila
    Gabenski, Brandon
    Okere, Arinzechukwu N.
    Honeywell, Marlon S.
    US PHARMACIST, 2020, 45 (09) : 30 - 32
  • [25] MiniMed continuous glucose monitoring system
    不详
    BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11): : AR1 - AR1
  • [26] MICRONEEDLE-BASED SYSTEM FOR MINIMALLY INVASIVE CONTINUOUS MONITORING OF GLUCOSE IN THE DERMAL INTERSTITIAL FLUID
    Ribet, Federico
    Stemme, Goran
    Roxhed, Niclas
    2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 408 - 411
  • [27] An Automatic Denoising Method with Estimation of Noise Level and Detection of Noise Variability in Continuous Glucose Monitoring
    Zhao, Hong
    Zhao, Chunhui
    IFAC PAPERSONLINE, 2016, 49 (07): : 785 - 790
  • [28] A MEMS SENSOR FOR CONTINUOUS MONITORING OF GLUCOSE IN SUBCUTANEOUS TISSUE
    Huang, X.
    Li, S.
    Schultz, J.
    Wang, Q.
    Lin, Q.
    IEEE 22ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2009), 2009, : 352 - 355
  • [29] Continuous glucose monitoring on the ICU using a subcutaneous sensor
    Punke, M. A.
    Decker, C.
    Wodack, K.
    Reuter, D. A.
    Kluge, S.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2015, 110 (05) : 360 - 363
  • [30] Glucose prediction from continuous subcutaneous monitoring data
    Maran, A
    Sparacino, G
    Pavanini, A
    Crepaldi, C
    Poscia, A
    Tiengo, A
    Avogaro, A
    Cobelli, C
    DIABETES, 2004, 53 : A105 - A105