Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement

被引:6
|
作者
Nguyen, Quoc Khanh [1 ,2 ]
Kim, Seungman [1 ]
Han, Seong-Heum [1 ]
Ro, Seung-Kook [1 ]
Kim, Seung-Woo [3 ]
Kim, Young-Jin [3 ]
Kim, Wooram [3 ]
Oh, Jeong Seok [1 ,2 ]
机构
[1] Korea Inst Machinery & Mat, Dept Ultraprecis Machines & Syst, Daejeon 34103, South Korea
[2] Univ Sci & Technol, Dept Nanomechatron, Daejeon 34113, South Korea
[3] Korea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
multilateration; self-calibration; absolute distance measurement; initial guess; TRACKING INTERFEROMETER SYSTEM; LARGE-SCALE METROLOGY; OF-FLIGHT MEASUREMENT; 3-DIMENSIONAL COORDINATE; LASER TRACKERS; ARRANGEMENT;
D O I
10.3390/s20247288
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 mu m, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 mu m, while the maximum deviation estimated by the conventional self-calibration method was 711.9 mu m. Validation of 3D coordinate measurements in a 1000 mm x 1000 mm x 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 mu m. Conversely, the maximum difference was 98.8 mu m using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [41] AIRCRAFT MEASUREMENT OF ELECTRIC-FIELD - SELF-CALIBRATION
    WINN, WP
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1993, 98 (D4) : 7351 - 7365
  • [42] An algorithm for an eye tracking system with self-calibration
    Takegami, Takeshi
    Gotoh, Toshiyuki
    Ohyama, Ghen
    Systems and Computers in Japan, 2002, 33 (10) : 10 - 20
  • [43] Absolute self-calibration of the quantum efficiency of single-photon detectors
    Chen, Xi-Hao
    Zhai, Yan-Hua
    Zhang, Da
    Wu, Ling-An
    OPTICS LETTERS, 2006, 31 (16) : 2441 - 2443
  • [44] SILICON PHOTO-DIODE ABSOLUTE SPECTRAL RESPONSE SELF-CALIBRATION
    ZALEWSKI, EF
    GEIST, J
    APPLIED OPTICS, 1980, 19 (08): : 1214 - 1216
  • [45] A digital self-calibration circuit for absolute optical rotary encoder microsystems
    Liberali, V
    Cherchi, F
    Disingrini, L
    Gottardi, M
    Gregori, S
    Torelli, G
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (01) : 149 - 157
  • [46] The Self-calibration of Varying Internal Camera Parameters Based on Image of Dual Absolute Quadric Transformation
    Jiang, Ze-tao
    Liu, Shan-chao
    INFORMATION AND AUTOMATION, 2011, 86 : 452 - +
  • [47] Self-Calibration for an Object Integrative Handling System
    Detert, T.
    Huesing, M.
    Corves, B.
    2018 INTERNATIONAL CONFERENCE ON RECONFIGURABLE MECHANISMS AND ROBOTS (REMAR), 2018,
  • [48] An improved algorithm for two-image camera self-calibration and Euclidean structure recovery using absolute quadric
    Huang, CR
    Chen, CS
    Chung, PC
    PATTERN RECOGNITION, 2004, 37 (08) : 1713 - 1722
  • [49] Absolute self-calibration of the quantum efficiency of single-photon detectors
    Chang, JT
    Wu, LA
    ACTA PHYSICA SINICA, 2003, 52 (05) : 1132 - 1136
  • [50] Self-calibration and simulation of the structure parameters in a light-pen vision measurement system
    Huang, Feng-Shan
    Liu, Shu-Gui
    Peng, Kai
    Qian, Hui-Fen
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2006, 17 (06): : 705 - 708