Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement

被引:6
|
作者
Nguyen, Quoc Khanh [1 ,2 ]
Kim, Seungman [1 ]
Han, Seong-Heum [1 ]
Ro, Seung-Kook [1 ]
Kim, Seung-Woo [3 ]
Kim, Young-Jin [3 ]
Kim, Wooram [3 ]
Oh, Jeong Seok [1 ,2 ]
机构
[1] Korea Inst Machinery & Mat, Dept Ultraprecis Machines & Syst, Daejeon 34103, South Korea
[2] Univ Sci & Technol, Dept Nanomechatron, Daejeon 34113, South Korea
[3] Korea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
multilateration; self-calibration; absolute distance measurement; initial guess; TRACKING INTERFEROMETER SYSTEM; LARGE-SCALE METROLOGY; OF-FLIGHT MEASUREMENT; 3-DIMENSIONAL COORDINATE; LASER TRACKERS; ARRANGEMENT;
D O I
10.3390/s20247288
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 mu m, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 mu m, while the maximum deviation estimated by the conventional self-calibration method was 711.9 mu m. Validation of 3D coordinate measurements in a 1000 mm x 1000 mm x 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 mu m. Conversely, the maximum difference was 98.8 mu m using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [21] Self-Calibration Sensor for Contactless Voltage Measurement Based on Dynamic Capacitance
    Suo, Chunguang
    Huang, Rujin
    Zhou, Guoqiong
    Zhang, Wenbin
    Wang, Yanyun
    He, Mingxing
    SENSORS, 2023, 23 (08)
  • [22] Study of self-calibration and multilateration in machine tool volumetric verification for laser tracker error reduction
    Aguado, Sergio
    Santolaria, Jorge
    Samper, David
    Aguilar, Juan J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2014, 228 (07) : 659 - 672
  • [23] A Linear Self-calibration Method Based on Active Vision System
    Xiong, Jiu-Long
    Zhang, Qi
    Xia, Jun-Ying
    Peng, Shan
    Luo, Fei-Lu
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOLS 1-9, 2009, : 2290 - 2293
  • [24] Self-calibration of monocular vision system based on planar points
    Zhao, Yu
    Xu, Lichao
    Image Processing: Machine Vision Applications VIII, 2015, 9405
  • [25] Self-calibration of multiplication optic fiber's length in an optic fiber interferometer for distance measurement
    Huang, Shaomei
    Ye, Shenghua
    Duan, Fajie
    Zhongguo Jiguang/Chinese Journal of Lasers, 2000, 27 (09): : 805 - 808
  • [26] Self-calibration of workspace measurement and positioning system by using inter-scanning
    Ren, Yong-Jie
    Zhu, Ji-Gui
    Wu, Jun
    Xue, Bin
    Yang, Ling-Hui
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (03): : 609 - 616
  • [27] Improved self-calibration algorithm of absolute dual quadric - art. no. 67882L
    Sun, Min
    MIPPR 2007: PATTERN RECOGNITION AND COMPUTER VISION, 2007, 6788 : L7882 - L7882
  • [28] Absolute distance measurement system based on optical multiplication
    Yang, Tian-Bo
    Guo, Hong
    Li, Da-Cheng
    Guangxue Jishu/Optical Technique, 2006, 32 (01): : 39 - 41
  • [29] Camera self-calibration based on circle
    Zhang, BW
    Liang, D
    Wu, FC
    VISUALIZATION AND OPTIMIZATION TECHNIQUES, 2001, 4553 : 286 - 289
  • [30] Ball-bar based self-calibration technique for five-axis optical measurement system
    Du, X. M.
    Gu, Jiajun
    Harding, K. G.
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS II, 2012, 8563