Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement

被引:6
|
作者
Nguyen, Quoc Khanh [1 ,2 ]
Kim, Seungman [1 ]
Han, Seong-Heum [1 ]
Ro, Seung-Kook [1 ]
Kim, Seung-Woo [3 ]
Kim, Young-Jin [3 ]
Kim, Wooram [3 ]
Oh, Jeong Seok [1 ,2 ]
机构
[1] Korea Inst Machinery & Mat, Dept Ultraprecis Machines & Syst, Daejeon 34103, South Korea
[2] Univ Sci & Technol, Dept Nanomechatron, Daejeon 34113, South Korea
[3] Korea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
multilateration; self-calibration; absolute distance measurement; initial guess; TRACKING INTERFEROMETER SYSTEM; LARGE-SCALE METROLOGY; OF-FLIGHT MEASUREMENT; 3-DIMENSIONAL COORDINATE; LASER TRACKERS; ARRANGEMENT;
D O I
10.3390/s20247288
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 mu m, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 mu m, while the maximum deviation estimated by the conventional self-calibration method was 711.9 mu m. Validation of 3D coordinate measurements in a 1000 mm x 1000 mm x 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 mu m. Conversely, the maximum difference was 98.8 mu m using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [1] An Improved Self-calibration Algorithm for Multilateration Coordinates Measuring System
    Miao, Dongjing
    Wang, Guolei
    Li, Jianshuan
    He, Mingzhao
    Kang, Yao
    8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [2] A Position Self-Calibration Method in Multilateration
    Lin Yunsong
    Peng Liangfu
    2017 FORUM ON COOPERATIVE POSITIONING AND SERVICE (CPGPS), 2017, : 101 - 105
  • [3] A self-calibration method for robotic measurement system
    Gong, CH
    Yuan, JX
    Ni, J
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 174 - 181
  • [4] Self-calibration method for robotic measurement system
    Gong, Chunhe
    Yuan, Jingxia
    Ni, Jun
    American Society of Mechanical Engineers, Manufacturing Engineering Division, MED, 1999, 10 : 879 - 888
  • [5] An Improved Rotation-based Self-calibration
    Li, Canlin
    Lu, Jiajie
    Ma, Lizhuang
    2009 11TH IEEE INTERNATIONAL CONFERENCE ON COMPUTER-AIDED DESIGN AND COMPUTER GRAPHICS, PROCEEDINGS, 2009, : 623 - 626
  • [6] Real time self-calibration of digital measurement system
    Xi, YB
    Gu, TX
    2005 INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS, VOLS 1 AND 2, PROCEEDINGS: VOL 1: COMMUNICATION THEORY AND SYSTEMS, 2005, : 1362 - 1365
  • [7] Self-calibration and data fusion for humidity measurement system
    Huang Xiao-yin
    Zhou Ping
    Zhang Yue
    PROCEEDINGS OF 2005 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1 AND 2, 2005, : 1265 - 1268
  • [8] Efficient camera self-calibration method based on the absolute dual quadric
    Jin, Jing
    Li, Xiaofeng
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2013, 30 (03) : 287 - 292
  • [9] A novel self-calibration method with POE-based model and distance error measurement for serial manipulators
    Hu, Shenghai
    Zhang, Manhui
    Zhou, Chao
    Tian, Feihong
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (10) : 4911 - 4923
  • [10] A novel self-calibration method with POE-based model and distance error measurement for serial manipulators
    Shenghai Hu
    Manhui Zhang
    Chao Zhou
    Feihong Tian
    Journal of Mechanical Science and Technology, 2017, 31 : 4911 - 4923