Magnetic resonance imaging of trilucent TM breast implants

被引:3
|
作者
Elson, EM
Jones, A
King, R
Chapman, P
Stanek, J
Irvine, AT
Bingham, JB
机构
[1] Guys & St Thomas NHS Trust, London, England
[2] Blackheath Hosp, London, England
关键词
magnetic resonance imaging (MRI); breast implants; breast implant rupture;
D O I
10.1053/crad.2001.0767
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To demonstrate the magnetic resonance imaging (MRI) appearances of intact and ruptured Trilucent TM implants with imaging and surgical correlation. The appearances of the implant transponder artefact are also described MATERIALS AND METHODS: A retrospective review of the MRI findings in 34 patients with bilateral subpectoral Trilucent TM breast implants (Lipomatrix, Inc./Collagen Aesthetics International Inc., Neuchatel, Switzerland) was performed. Patients under implant surveillance and those with suspected implant rupture formed the study group. Imaging findings were correlated with surgical appearances. RESULTS: Surgical correlation was available in 53% of patients. Fifty per cent (18/36) of implants were intact at surgery, 50% (18/36) of implants were ruptured. Of the 18 ruptured implants, 17 were intracapsular ruptures and one an extracapsular rupture. The sensitivity of MRI for detection of intracapsular rupture in Trilucent TM breast implants was 82% specificity 76%, positive predictive value 78%, negative predictive value 81% and accuracy 79% in this study group. No case of implant rupture was obscured by the transponder artefact. Four implants were found to have 'pseudocapsules' at surgery (5.9%), the implants were intact with fluid present between the implant and capsule. Only one pseudocapsule was demonstrated on MRI. CONCLUSION: Magnetic resonance imaging is currently the most accurate technique for diagnosis of implant rupture in Trilucent TM breast implants. Transponder artefact does not appear to interfere with the assseessment of implant rupture. (C) 2002 The Royal College of Radiologists.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 50 条
  • [31] Magnetic resonance imaging of the breast
    El Khouli, Riham H.
    Jacobs, Michael A.
    Bluemke, David A.
    SEMINARS IN ROENTGENOLOGY, 2008, 43 (04) : 265 - 281
  • [32] Breast magnetic resonance imaging
    Harms, SE
    SEMINARS IN ULTRASOUND CT AND MRI, 1998, 19 (01) : 104 - 120
  • [33] Magnetic Resonance Imaging of the Breast
    Holbrook, Anna I.
    Newell, Mary S.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2016, 59 (02): : 394 - 402
  • [34] Retromammary fluid collection as a late complication of breast implants -: Magnetic resonance imaging findings
    Pineda, V
    Cáceres, J
    Pernas, JC
    Català, J
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (03) : 386 - 389
  • [35] Trilucent breast implants - A personal review of the current controversies (May 1999)
    McGregor, JC
    SCOTTISH MEDICAL JOURNAL, 2000, 45 (06) : 177 - 179
  • [36] True double capsules in oil-based (Trilucent) breast implants
    Colville, RJI
    McLean, NR
    Cross, PA
    BRITISH JOURNAL OF PLASTIC SURGERY, 2002, 55 (03): : 270 - 271
  • [37] Trilucent breast implants - a personal review of the current controversies (May 1999)
    McGregor, JC
    BRITISH JOURNAL OF PLASTIC SURGERY, 1999, 52 (06): : 512 - 513
  • [38] Magnetic resonance imaging: The evolution of breast imaging
    Heywang-Koebrunner, Sylvia H.
    Hacker, Astrid
    Sedlacek, Stefan
    BREAST, 2013, 22 : S77 - S82
  • [39] Imaging in breast cancer: Magnetic resonance imaging
    Lehman, CD
    Schnall, MD
    BREAST CANCER RESEARCH, 2005, 7 (05) : 215 - 219
  • [40] MAGNETIC RESONANCE IMAGING: THE EVOLUTION OF BREAST IMAGING
    Heywang-Koebrunner, S. H.
    BREAST, 2013, 22 : S8 - S9