Magnetic resonance imaging of trilucent TM breast implants

被引:3
|
作者
Elson, EM
Jones, A
King, R
Chapman, P
Stanek, J
Irvine, AT
Bingham, JB
机构
[1] Guys & St Thomas NHS Trust, London, England
[2] Blackheath Hosp, London, England
关键词
magnetic resonance imaging (MRI); breast implants; breast implant rupture;
D O I
10.1053/crad.2001.0767
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To demonstrate the magnetic resonance imaging (MRI) appearances of intact and ruptured Trilucent TM implants with imaging and surgical correlation. The appearances of the implant transponder artefact are also described MATERIALS AND METHODS: A retrospective review of the MRI findings in 34 patients with bilateral subpectoral Trilucent TM breast implants (Lipomatrix, Inc./Collagen Aesthetics International Inc., Neuchatel, Switzerland) was performed. Patients under implant surveillance and those with suspected implant rupture formed the study group. Imaging findings were correlated with surgical appearances. RESULTS: Surgical correlation was available in 53% of patients. Fifty per cent (18/36) of implants were intact at surgery, 50% (18/36) of implants were ruptured. Of the 18 ruptured implants, 17 were intracapsular ruptures and one an extracapsular rupture. The sensitivity of MRI for detection of intracapsular rupture in Trilucent TM breast implants was 82% specificity 76%, positive predictive value 78%, negative predictive value 81% and accuracy 79% in this study group. No case of implant rupture was obscured by the transponder artefact. Four implants were found to have 'pseudocapsules' at surgery (5.9%), the implants were intact with fluid present between the implant and capsule. Only one pseudocapsule was demonstrated on MRI. CONCLUSION: Magnetic resonance imaging is currently the most accurate technique for diagnosis of implant rupture in Trilucent TM breast implants. Transponder artefact does not appear to interfere with the assseessment of implant rupture. (C) 2002 The Royal College of Radiologists.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 50 条
  • [21] Safety of metallic implants in magnetic resonance imaging
    Ho, HS
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 472 - 477
  • [22] Magnetic resonance imaging after cochlear implants
    Naif Bawazeer
    Hella Vuong
    Sophie Riehm
    Francis Veillon
    Anne Charpiot
    JournalofOtology, 2019, 14 (01) : 22 - 25
  • [23] Magnetic resonance imaging and active cardiac implants
    Reiter T.
    Bauer W.R.
    Herzschrittmachertherapie + Elektrophysiologie, 2019, 30 (2) : 177 - 182
  • [24] MAGNETIC-RESONANCE-IMAGING AND OTOLOGIC IMPLANTS
    HOWARD, PE
    REAMS, CL
    KURLAND, R
    WRIGHT, J
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1986, : 103 - 103
  • [25] Magnetic resonance imaging after cochlear implants
    Bawazeer, Naif
    Vuong, Hella
    Riehm, Sophie
    Veillon, Francis
    Charpiot, Anne
    JOURNAL OF OTOLOGY, 2019, 14 (01) : 22 - 25
  • [26] Magnetic resonance imaging of the breast
    Vanel, D
    Tardivon, A
    JOURNAL DE RADIOLOGIE, 1995, 76 (12): : 1067 - 1067
  • [27] Magnetic resonance imaging of the breast
    Balu-Maestro, C
    JOURNAL DE RADIOLOGIE, 2001, 82 (01): : 17 - 26
  • [28] Magnetic resonance imaging of the breast
    Rosenberg, R
    Cambron, LD
    Williamson, MR
    WESTERN JOURNAL OF MEDICINE, 1996, 165 (1-2): : 58 - 59
  • [29] Breast Magnetic Resonance Imaging
    DuBose, Cheryl
    RADIOLOGIC TECHNOLOGY, 2020, 91 (05) : 447M - 464M
  • [30] Breast Magnetic Resonance Imaging
    Fuchsjaeger, Michael H.
    Boetes, Carla
    Helbich, Thomas
    Heywang-Koebrunner, Sylvia H.
    Ikeda, Debra
    Morris, Elizabeth
    Sardanelli, Francesco
    BREAST CARE, 2010, 5 (06) : 425 - 429