Lamb Waves and Adaptive Beamforming for Aberration Correction in Medical Ultrasound Imaging

被引:13
|
作者
Mozaffarzadeh, Moein [1 ]
Minonzio, Claudio [1 ]
de Jong, Nico [1 ,2 ]
Verweij, Martin D. [1 ,2 ]
Hemm, Simone [3 ]
Daeichin, Verya [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Lab Med Imaging, NL-2628 CJ Delft, Netherlands
[2] Erasmus MC, Thoraxctr, Dept Biomed Engn, NL-3015 GD Rotterdam, Netherlands
[3] Univ Appl Sci & Arts Northwestern Switzerland, Sch Life Sci, Inst Med Engn & Med Informat, CH-4132 Muttenz, Switzerland
关键词
Slabs; Imaging; Ultrasonic imaging; Array signal processing; Skull; Probes; Acoustics; Adaptive beamforming; deep brain stimulation (DBS); Lamb waves; sound speed map; transcranial ultrasound imaging (TUI); TRANSCRANIAL ULTRASOUND; TIME-REVERSAL; BRAIN HELMET; PULSE-ECHO; SKULL; PHASE; TEMPERATURE; EXCITATION; ARTIFACTS; ALGORITHM;
D O I
10.1109/TUFFC.2020.3007345
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Phase aberration in transcranial ultrasound imaging (TUI) caused by the human skull leads to an inaccurate image reconstruction. In this article, we present a novel method for estimating the speed of sound and an adaptive beamforming technique for phase aberration correction in a flat polyvinylchloride (PVC) slab as a model for the human skull. First, the speed of sound of the PVC slab is found by extracting the overlapping quasi-longitudinal wave velocities of symmetrical Lamb waves in the frequency-wavenumber domain. Then, the thickness of the plate is determined by the echoes from its front and back side. Next, an adaptive beamforming method is developed, utilizing the measured sound speed map of the imaging medium. Finally, to minimize reverberation artifacts caused by strong scatterers (i.e., needles), a dual probe setup is proposed. In this setup, we image the medium from two opposite directions, and the final image can be the minimum intensity projection of the inherently co-registered images of the opposed probes. Our results confirm that the Lamb wave method estimates the longitudinal speed of the slab with an error of 3.5% and is independent of its shear wave speed. Benefiting from the acquired sound speed map, our adaptive beamformer reduces (in real time) a mislocation error of 3.1, caused by an 8 mm slab, to 0.1 mm. Finally, the dual probe configuration shows 7 dB improvement in removing reverberation artifacts of the needle, at the cost of only 2.4-dB contrast loss. The proposed image formation method can be used, e.g., to monitor deep brain stimulation procedures and localization of the electrode(s) deep inside the brain from two temporal bones on the sides of the human skull.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 50 条
  • [41] Adaptive acoustic imaging using aberration correction in difficult materials
    Sharples, SD
    Clark, M
    Collison, IJ
    Somekh, MG
    INSIGHT, 2005, 47 (02) : 78 - 80
  • [42] Adaptive and Compressive Beamforming Using Deep Learning for Medical Ultrasound
    Khan, Shujaat
    Huh, Jaeyoung
    Ye, Jong Chul
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (08) : 1558 - 1572
  • [43] Phase-Aberration Correction in Shear-Wave Elastography Imaging Using Local Speed-of-Sound Adaptive Beamforming
    Chintada, Bhaskara R.
    Rau, Richard
    Goksel, Orcun
    FRONTIERS IN PHYSICS, 2021, 9 (09):
  • [44] Minimum variance beamforming combined with covariance matrix-based adaptive weighting for medical ultrasound imaging
    Yuanguo Wang
    Yadan Wang
    Mingzhou Liu
    Zhengfeng Lan
    Chichao Zheng
    Hu Peng
    BioMedical Engineering OnLine, 21
  • [45] A coherence-based phase aberration correction method in medical ultrasound
    XIA Xinyuan
    LI Ping
    WU Wentao
    MENG Xiaohui
    ChineseJournalofAcoustics, 2015, 34 (03) : 217 - 229
  • [46] A coherence-based phase aberration correction method in medical ultrasound
    Institute of Acoustics, Chinese Academy of Sciences, Beijing
    100190, China
    不详
    100049, China
    Shengxue Xuebao, 2 (276-284):
  • [47] Minimum variance beamforming combined with covariance matrix-based adaptive weighting for medical ultrasound imaging
    Wang, Yuanguo
    Wang, Yadan
    Liu, Mingzhou
    Lan, Zhengfeng
    Zheng, Chichao
    Peng, Hu
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [48] INFLUENCE OF MISSING ARRAY ELEMENTS ON PHASE ABERRATION CORRECTION FOR MEDICAL ULTRASOUND
    KARAMAN, M
    KOYMEN, H
    ATALAR, A
    ODONNELL, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (05) : 613 - 620
  • [49] Fast adaptive beamforming through a cascade structure for ultrasound imaging
    Seyede Elham Shamsian
    Sayed Mahmoud Sakhaei
    Journal of Medical Ultrasonics, 2019, 46 : 287 - 296
  • [50] Fast adaptive beamforming through a cascade structure for ultrasound imaging
    Shamsian, Seyede Elham
    Sakhaei, Sayed Mahmoud
    JOURNAL OF MEDICAL ULTRASONICS, 2019, 46 (03) : 287 - 296