Lamb Waves and Adaptive Beamforming for Aberration Correction in Medical Ultrasound Imaging

被引:13
|
作者
Mozaffarzadeh, Moein [1 ]
Minonzio, Claudio [1 ]
de Jong, Nico [1 ,2 ]
Verweij, Martin D. [1 ,2 ]
Hemm, Simone [3 ]
Daeichin, Verya [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Lab Med Imaging, NL-2628 CJ Delft, Netherlands
[2] Erasmus MC, Thoraxctr, Dept Biomed Engn, NL-3015 GD Rotterdam, Netherlands
[3] Univ Appl Sci & Arts Northwestern Switzerland, Sch Life Sci, Inst Med Engn & Med Informat, CH-4132 Muttenz, Switzerland
关键词
Slabs; Imaging; Ultrasonic imaging; Array signal processing; Skull; Probes; Acoustics; Adaptive beamforming; deep brain stimulation (DBS); Lamb waves; sound speed map; transcranial ultrasound imaging (TUI); TRANSCRANIAL ULTRASOUND; TIME-REVERSAL; BRAIN HELMET; PULSE-ECHO; SKULL; PHASE; TEMPERATURE; EXCITATION; ARTIFACTS; ALGORITHM;
D O I
10.1109/TUFFC.2020.3007345
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Phase aberration in transcranial ultrasound imaging (TUI) caused by the human skull leads to an inaccurate image reconstruction. In this article, we present a novel method for estimating the speed of sound and an adaptive beamforming technique for phase aberration correction in a flat polyvinylchloride (PVC) slab as a model for the human skull. First, the speed of sound of the PVC slab is found by extracting the overlapping quasi-longitudinal wave velocities of symmetrical Lamb waves in the frequency-wavenumber domain. Then, the thickness of the plate is determined by the echoes from its front and back side. Next, an adaptive beamforming method is developed, utilizing the measured sound speed map of the imaging medium. Finally, to minimize reverberation artifacts caused by strong scatterers (i.e., needles), a dual probe setup is proposed. In this setup, we image the medium from two opposite directions, and the final image can be the minimum intensity projection of the inherently co-registered images of the opposed probes. Our results confirm that the Lamb wave method estimates the longitudinal speed of the slab with an error of 3.5% and is independent of its shear wave speed. Benefiting from the acquired sound speed map, our adaptive beamformer reduces (in real time) a mislocation error of 3.1, caused by an 8 mm slab, to 0.1 mm. Finally, the dual probe configuration shows 7 dB improvement in removing reverberation artifacts of the needle, at the cost of only 2.4-dB contrast loss. The proposed image formation method can be used, e.g., to monitor deep brain stimulation procedures and localization of the electrode(s) deep inside the brain from two temporal bones on the sides of the human skull.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 50 条
  • [21] Real-time Embedded Implementation of Adaptive Beamforming for Medical Ultrasound Imaging
    Chen, Junying
    Chen, Jinhui
    Mm, Huaqing
    Wang, Xiaohang
    PROCEEDINGS OF 2016 SIXTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC 2016), 2016, : 356 - 360
  • [22] Adaptive diagonal loaded minimum variance beamforming applied to medical ultrasound imaging
    Liu Hao-lin
    Zhang Zhi-hong
    Liu Dong-quan
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (05) : 1826 - 1832
  • [23] Adaptive field-of-view imaging for efficient receive beamforming in medical ultrasound imaging systems
    Agarwal, Anup
    Yoo, Yang Mo
    Schneider, Fabio Kurt
    Kim, Yongmin
    ULTRASONICS, 2008, 48 (05) : 384 - 393
  • [24] Adaptive signal processing in medical ultrasound beamforming
    Viola, F
    Walker, WF
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 1980 - 1983
  • [25] Adaptive Beamforming with Coded Excitation in Ultrasound Imaging
    Szasz, Teodora
    Vaida, Mircea-Florin
    2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,
  • [26] HYBRID ADAPTIVE/NONADAPTIVE BEAMFORMING FOR ULTRASOUND IMAGING
    Albulayli, M.
    Rakhmatov, D.
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 1061 - 1065
  • [27] Beamforming with sparse prior in ultrasound medical imaging
    Szasz, Teodora
    Basarab, Adrian
    Vaida, Mircea-Florin
    Kouame, Denis
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1077 - 1080
  • [28] Minimum Variance Beamforming Combined with Adaptive Coherence Weighting Applied to Medical Ultrasound Imaging
    Asl, Babak Mohammadzadeh
    Mahloojifar, Ali
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (09) : 1923 - 1931
  • [29] Fast Marching based Tissue Adaptive Delay Estimation for Aberration Corrected Delay and Sum Beamforming in Ultrasound Imaging
    Asif, M. S.
    Malama, Gayathri
    Madhavanunni, A. N.
    Melapudi, Vikram
    Rahul, V
    Patil, Abhijit
    Langoju, Rajesh
    Panicker, Mahesh Raveendranatha
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023, : 1 - 4
  • [30] Harmonic source wavefront aberration correction for ultrasound imaging
    Dianis, Scott W.
    von Ramm, Olaf T.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (01): : 507 - 517