Thermal Management of High Density Power Servers Using a Compact Two-phase Loop Cooling System

被引:0
|
作者
Choi, Jeehoon [1 ]
Ha, Minseok [2 ]
Lee, Yunkeun [3 ]
Graham, Samuel, Jr. [2 ]
Kang, Hwankook [1 ]
机构
[1] Dongeun ATS, 75 Fifth St,NW, Atlanta, GA 30303 USA
[2] Georgia Inst Technol, Atlanta, GA 30303 USA
[3] Zalman Tech Co Ltd, Atlanta, GA 30303 USA
关键词
Thermal management of server rack-mount enclosure; Two-phase loop cooling; High density power seminconductor; DESIGN; AIR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the increased usage of the internet and advances in computing hardware, the personal computing industry has shifted to lightweight mobile laptop platforms and the mobile internet devices. These personal computing devices are dependent on the cloud computing infrastructures that offer services delivered through data centers consisting of servers including multi-core semiconductor processors. Thermal management of most servers relies on a heat sink combined with fans providing forced air convection to reject heat to the ambient. However this conventional technique cannot accommodate the increased heat fluxes in the confined server enclosure and imposes a significant increase in noise, vibration, and power consumption. Innovative thermal management solutions must be employed to compensate for the increased heat dissipation in the space-constrained enclosures of high density power servers. In this paper, a compact two-phase loop cooling system was investigated to apply high density rack-mount server cooling applications. Experimental characterization shows that the system can reach a maximum heat flux of 22.22W/cm(2) with thermal resistance of 0.136 degrees C/W.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 50 条
  • [41] Experimental investigation of two-phase natural circulation loop as passive containment cooling system
    Lim, Sun Taek
    Kim, Koung Moon
    Kim, Haeseong
    Jerng, Dong-Wook
    Ahn, Ho Seon
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (12) : 3918 - 3929
  • [42] Thermal management system for high, dense, and compact power electronics
    Abo-Zahhad, Essam M.
    Hachicha, Ahmed Amine
    Said, Zafar
    Ghenai, Chaouki
    Ookawara, Shinichi
    ENERGY CONVERSION AND MANAGEMENT, 2022, 268
  • [43] Development and evaluation of a two-phase loop-type thermosyphon for cooling telecommunications system
    Kim, WT
    Song, KS
    Lee, Y
    INTERNATIONAL SYMPOSIUM ON LIQUID-LIQUID TWO PHASE FLOW AND TRANSPORT PHENOMENA, 1998, : 241 - 249
  • [44] Compact Two-Phase Immersion Cooling With Dielectric Fluid for PCB-Based Power Electronics
    Ristic-Smith, Aleksandar
    Rogers, Daniel J.
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2024, 5 : 1107 - 1118
  • [45] Numerical Simulation of the Mechanically Pumped Two-Phase cooling loop
    Liu Jie
    Zhou Enze
    Zhao Wenjun
    Cheng Cheng
    GREEN POWER, MATERIALS AND MANUFACTURING TECHNOLOGY AND APPLICATIONS, PTS 1 AND 2, 2011, 84-85 : 244 - 248
  • [46] Experimental investigation on startup of a novel two-phase cooling loop
    Liu Jie
    Pei Nian-qiang
    Guo Kai-hua
    He Zhen-hui
    Li Ting-xuen
    Gu Jian-ming
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (04) : 939 - 946
  • [47] EXPERIMENTAL INVESTIGATION OF TWO-PHASE PUMPLESS LOOP WITH WATER AS WORKING FLUID FOR POWER ELECTRONICS COOLING
    Raju, Rama V. S. V.
    Krishnan, Shankar
    PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [48] Size effects of a portable two-phase electronics cooling loop
    Saenen, Tom
    Baelmans, Martine
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1174 - 1185
  • [49] Two-phase thermosyphon loop for cooling outdoor telecommunication equipments
    Samba, Ahmadou
    Louahlia-Gualous, Hasna
    Le Masson, Stephane
    Noerterhaeuser, David
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1351 - 1360
  • [50] Two-Phase Closed-Loop Thermosyphon for Electronic Cooling
    Chang, C. -C.
    Kuo, S. -C.
    Ke, M. -T.
    Chen, S. -L.
    EXPERIMENTAL HEAT TRANSFER, 2010, 23 (02) : 144 - 156