Thermal Management of High Density Power Servers Using a Compact Two-phase Loop Cooling System

被引:0
|
作者
Choi, Jeehoon [1 ]
Ha, Minseok [2 ]
Lee, Yunkeun [3 ]
Graham, Samuel, Jr. [2 ]
Kang, Hwankook [1 ]
机构
[1] Dongeun ATS, 75 Fifth St,NW, Atlanta, GA 30303 USA
[2] Georgia Inst Technol, Atlanta, GA 30303 USA
[3] Zalman Tech Co Ltd, Atlanta, GA 30303 USA
关键词
Thermal management of server rack-mount enclosure; Two-phase loop cooling; High density power seminconductor; DESIGN; AIR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the increased usage of the internet and advances in computing hardware, the personal computing industry has shifted to lightweight mobile laptop platforms and the mobile internet devices. These personal computing devices are dependent on the cloud computing infrastructures that offer services delivered through data centers consisting of servers including multi-core semiconductor processors. Thermal management of most servers relies on a heat sink combined with fans providing forced air convection to reject heat to the ambient. However this conventional technique cannot accommodate the increased heat fluxes in the confined server enclosure and imposes a significant increase in noise, vibration, and power consumption. Innovative thermal management solutions must be employed to compensate for the increased heat dissipation in the space-constrained enclosures of high density power servers. In this paper, a compact two-phase loop cooling system was investigated to apply high density rack-mount server cooling applications. Experimental characterization shows that the system can reach a maximum heat flux of 22.22W/cm(2) with thermal resistance of 0.136 degrees C/W.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 50 条
  • [21] OPERATIONAL MAP AND THERMAL PERFORMANCE OF A THERMOSYPHON COOLING SYSTEM FOR COMPACT SERVERS
    Amalfi, Raffaele L.
    Hoang, Cong H.
    Enright, Ryan
    Cataldo, Filippo
    Marcinichen, Jackson B.
    Thome, John R.
    PROCEEDINGS OF ASME 2021 INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS (INTERPACK2021), 2021,
  • [22] Application of Two-Phase Spray Cooling for Thermal Management of Electronic Devices
    Visaria, Milan
    Mudawar, Issam
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2009, 32 (04): : 784 - 793
  • [23] Application of two-phase spray cooling for thermal management of electronic devices
    Visaria, Milan
    Mudawar, Issam
    2008 11TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, VOLS 1-3, 2008, : 275 - +
  • [24] A review of two-phase submerged boiling in thermal management of electronic cooling
    Fan, Simiao
    Duan, Fei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 150
  • [25] Thermal management of a high packing density array of power amplifiers using liquid cooling
    Williams, Z. A.
    Roux, J. A.
    JOURNAL OF ELECTRONIC PACKAGING, 2007, 129 (04) : 488 - 495
  • [26] Two-phase refrigerant flow in the evaporator of a stirling cooling system with a thermosyphon loop
    Celik, Serdar
    Ekren, Orhan
    EXPERIMENTAL HEAT TRANSFER, 2020, 33 (04) : 305 - 317
  • [27] Modeling and parametric study for a two-phase loop passive containment cooling system
    Zhang, Keyuan
    Zhou, Shaofei
    Wu, Xiaotian
    Li, Yaru
    Chi, Xiangyu
    Nan, Zezhao
    Wang, Naihua
    APPLIED THERMAL ENGINEERING, 2022, 213
  • [28] Actively pumped two-phase loop for spray cooling
    Lin, LC
    Ponnappan, R
    Yerkes, K
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2006, 20 (01) : 107 - 110
  • [29] Performance investigation of integrated thermal management system based on a pumped two-phase cooling system for electric vehicles
    Wang, Jun
    Ruan, Lin
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [30] A novel two-phase BPM drive system with high power density and low cost
    Li, Y
    Walls, TA
    Lloyd, JD
    Skinner, JL
    IAS '97 - CONFERENCE RECORD OF THE 1997 IEEE INDUSTRY APPLICATIONS CONFERENCE / THIRTY-SECOND IAS ANNUAL MEETING, VOLS 1-3, 1997, : 715 - 721