Performance evaluation of the white cell precursor channel on the Sysmex XN hematology analyzer in HIV specimens

被引:7
|
作者
Schapkaitz, Elise [1 ]
Khoza, Phoyisile [2 ]
机构
[1] Univ Witwatersrand, Med Sch, Dept Mol Med & Haematol, Johannesburg, South Africa
[2] Natl Hlth Lab Serv, Dept Mol Med & Haematol, Johannesburg, South Africa
关键词
human immunodeficiency virus; morphology flags; Sysmex XN; white blood cell differentials; XE-5000; WPC;
D O I
10.1002/jcla.22335
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Automated hematology analyzers generate white blood cell (WBC) suspect flags to indicate smears requiring manual review. In a human immunodeficiency virus (HIV) patient population with a high frequency of abnormal specimens, the usefulness of these flags depends on their sensitivity and specificity. The white cell precursor (WPC) channel on the Sysmex XN-9000 analyzer (Sysmex Corporation, Kobe, Japan) has recently been introduced in order to distinguish immature cells such as blasts and abnormal lymphocytes. Methods: The efficiency of the flags generated by WPC reflex testing was compared to the white cell differential (WDF) on the Sysmex XN-9000 in 400 routine HIV samples. Results: A flag was generated by the WDF channel in 346 (86.50%) samples. Addition of the WPC to the WDF resulted in a 20.99% reduction in the smear review rate. WPC analysis correctly identified the initial WDF flag in 59 (60.82%) samples with 'blasts?' or 'abnormal lympho?' flags. WPC showed an excellent sensitivity of 100%. However, the specificity remained poor. On investigation, samples with chronic infection/ inflammation (35.00%) and lymphopenia (63.25%) were associated with a high false positive rate of 76.32% and 55.56%, respectively. WPC analysis removed 45 (51.72%) coexisting 'atypical lympho?' false positive WDF flags. The 'atypical lympho?' flag showed an increased sensitivity and specificity of 88.46% and 74.67%, respectively. Conclusion: White cell precursor reflex testing showed improved flagging efficiency for the 'atypical lympho?' flag, which was a good indicator of reactive lymphocytes during chronic infection/inflammation. Nevertheless, the false positive rate for 'abnormal lympho/blasts?' was high in the presence of lymphopenia and infection.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] FLAGGING PERFORMANCE OF SYSMEX XN-SERIES HEMATOLOGY ANALYZER FOR MALARIA DETECTION
    Huh, Hee Jin
    Chung, Jae-Woo
    Chae, Seok Lae
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 44 - 44
  • [22] Evaluation of biological fluid analysis using the sysmex XN automatic hematology analyzer
    Aguadero, Vicente
    Cano-Corres, Ruth
    Berlanga, Eugenio
    Torra, Montserrat
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2018, 94 (05) : 680 - 688
  • [23] Evaluation of the performance of sysmex XN-3100 automated hematology analyzer regarding the sysmex XE-2100 and microscopic examination
    Incir, Said
    Palaoglu, Kerim Erhan
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2021, 46 (01): : 27 - 35
  • [24] PERFORMANCE EVALUATION OF THE HEMATOLOGY ANALYZER SYSMEX XE-5000 FOR WHITE BLOOD CELL ANALYSIS IN CEREBROSPINAL FLUID
    Perne, Andrea
    Hainfellner, Johannes A.
    Szekeres, Thomas
    Schwarzinger, Ilse
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S770 - S770
  • [25] Performance Evaluation of the Sysmex XE-5000 Hematology Analyzer for White Blood Cell Analysis in Cerebrospinal Fluid
    Perne, Andrea
    Hainfellner, Johannes A.
    Womastek, Irene
    Haushofer, Alexander
    Szekeres, Thomas
    Schwarzinger, Ilse
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2012, 136 (02) : 194 - 198
  • [26] Clinical case: Malaria detection by the Sysmex XN hematology analyzer
    Thomlimson, L.
    Ortega, N.
    Samaniego, L.
    Calvo, A.
    Martin, S.
    CLINICA CHIMICA ACTA, 2019, 493 : S256 - S256
  • [27] Evaluation of immature granulocyte parameters in myeloid neoplasms assayed by Sysmex XN hematology analyzer
    Lu, Qifeng
    Li, Ying
    Li, Tian
    Hou, Tingting
    Zhao, Yajuan
    Feng, Shu
    Yang, Xixian
    Zhu, Mengyu
    Shen, Yajuan
    JOURNAL OF HEMATOPATHOLOGY, 2022, 15 (01) : 1 - 6
  • [28] Evaluation of immature granulocyte parameters in myeloid neoplasms assayed by Sysmex XN hematology analyzer
    Qifeng Lu
    Ying Li
    Tian Li
    Tingting Hou
    Yajuan Zhao
    Shu Feng
    Xixian Yang
    Mengyu Zhu
    Yajuan Shen
    Journal of Hematopathology, 2022, 15 : 1 - 6
  • [29] Evaluation the diagnostic performance of immature granulocyte cells flag on automated hematology analyzer sysmex XN-series
    Chieh-Hsi, W.
    Fang-Yu, W.
    Hsiang-Ling, H.
    CLINICA CHIMICA ACTA, 2022, 530 : S187 - S187
  • [30] The new hematology analyzer Sysmex XE-2100 - Performance evaluation of a novel white blood cell differential technology
    Ruzicka, K
    Veitl, M
    Thalhammer-Scherrer, R
    Schwarzinger, I