Serial Doppler echocardiographic evaluation of bioprosthetic valves in the tricuspid position

被引:12
|
作者
Kobayashi, Y
Nagata, S
Ohmori, F
Eishi, K
Nakano, K
Miyatake, K
机构
[1] NATL CARDIOVASC CTR,DEPT INTERNAL MED,DIV CARDIOL,SUITA,OSAKA 565,JAPAN
[2] NATL CARDIOVASC CTR,DEPT INTERNAL MED,DIV CARDIOVASC SURG,SUITA,OSAKA 565,JAPAN
关键词
D O I
10.1016/0735-1097(96)00056-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study sought to evaluate bioprosthetic valve dysfunction in the tricuspid position by serial Doppler echocardiography. Background. Few reports on the long-term results of tricuspid valve replacement with bioprosthetic valves are evaluated by serial Doppler echocardiography. Methods. Between September 1979 and December 1993, 95 patients underwent tricuspid valve replacement with bioprosthetic valves at our facility. Sixty patients who underwent serial Doppler echocardiographic examination at intervals of at least 2 years after operation were included in the final analysis. These patients were followed up from 1.5 to 13.0 years (mean 5.8 +/- 2.5). Results. The actuarial rates of freedom from bioprosthetic valve stenosis and regurgitation at 10 years were 46% and 51%, respectively. The prevalence of bioprosthetic valve stenosis and regurgitation increased progressively in a linear manner beginning 1 or 2 years after tricuspid valve replacement. Right heart failure developed during follow up in 20 of the 25 patients with bioprosthetic valve dysfunction. Conclusions. The long-term durability of bioprosthetic valves in the tricuspid position was substantially lower in our study than that reported in previous studies. Tricuspid bioprosthetic valve dysfunction increased progressively in a linear manner beginning 1 to 2 years after tricuspid valve replacement.
引用
收藏
页码:1693 / 1697
页数:5
相关论文
共 50 条
  • [41] Feasibility of intentional bioprosthetic valve fracture in the tricuspid position
    Hagel, Jonathon A.
    Lin, C. Huie
    Qureshi, Athar M.
    Tanase, Daniel
    Eicken, Andreas
    Zampi, Jeffrey D.
    Cabalka, Allison K.
    Anderson, Jason
    Shahanavaz, Shabana
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 104 (03) : 523 - 530
  • [42] CONTINUOUS WAVE DOPPLER ESTIMATES OF THE SEVERITY OF STENOSIS FOR BIOPROSTHETIC VALVES IN THE MITRAL AND TRICUSPID POSITIONS - STUDIES IN A CHRONIC LAMB MODEL
    VALDESCRUZ, LM
    JONES, M
    MAIN, J
    EIDBO, E
    SAHN, DJ
    SWENSSON, RE
    KASHANI, IA
    ELIAS, W
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) : 493 - 493
  • [43] Unusual echocardiographic views of bicuspid and tricuspid pulmonic valves
    McAleer, E
    Kort, S
    Rosenzweig, BP
    Katz, ES
    Tunick, PA
    Phoon, CK
    Kronzon, I
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (10) : 1036 - 1038
  • [44] DOPPLER ECHOCARDIOGRAPHIC FINDINGS IN RHEUMATIC TRICUSPID STENOSIS
    PARRIS, TM
    PANIDIS, IP
    ROSS, J
    MINTZ, GS
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (16): : 1414 - 1416
  • [45] Doppler-Echocardiographic Assessment of Tricuspid Regurgitation
    Topilsky, Yan
    Michelena, Hector I.
    Messika-Zeitoun, David
    Sarano, Maurice Enriquez
    PROGRESS IN CARDIOVASCULAR DISEASES, 2018, 61 (5-6) : 397 - 403
  • [46] Influence of pulmonic position on durability of bioprosthetic heart valves
    Fukada, J
    Morishita, K
    Komatsu, K
    Abe, T
    ANNALS OF THORACIC SURGERY, 1997, 64 (06): : 1678 - 1680
  • [47] BALLOON DILATATION OF PORCINE BIOPROSTHETIC VALVES IN THE PULMONARY POSITION
    WALDMAN, JD
    SCHOEN, FJ
    KIRKPATRICK, SE
    MATHEWSON, JW
    GEORGE, L
    LAMBERTI, JJ
    CIRCULATION, 1987, 76 (01) : 109 - 114
  • [48] DOPPLER-ECHOCARDIOGRAPHIC EVALUATION OF NORMAL AORTIC AND MITRAL STARR PROSTHETIC VALVES
    LEFEBVRE, E
    ISORNI, C
    REY, JL
    LESBRE, JP
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1987, 80 (07): : 1105 - 1114
  • [49] Echocardiographic Images of a Melody Valve in the Tricuspid Position
    Khan, Sairah
    Cheatham, John P.
    Kollins, Kevin
    Cua, Clifford L.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (03): : E98 - E100
  • [50] CLINICAL COMPARATIVE-STUDY BETWEEN MITRAL MECHANICAL AND BIOPROSTHETIC VALVES - WHAT IS THE BENEFIT OF BIOPROSTHETIC VALVES IN THE MITRAL POSITION
    KAWACHI, Y
    TOKUNAGA, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1990, 54 (12): : 1525 - 1534