Serial Doppler echocardiographic evaluation of bioprosthetic valves in the tricuspid position

被引:12
|
作者
Kobayashi, Y
Nagata, S
Ohmori, F
Eishi, K
Nakano, K
Miyatake, K
机构
[1] NATL CARDIOVASC CTR,DEPT INTERNAL MED,DIV CARDIOL,SUITA,OSAKA 565,JAPAN
[2] NATL CARDIOVASC CTR,DEPT INTERNAL MED,DIV CARDIOVASC SURG,SUITA,OSAKA 565,JAPAN
关键词
D O I
10.1016/0735-1097(96)00056-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study sought to evaluate bioprosthetic valve dysfunction in the tricuspid position by serial Doppler echocardiography. Background. Few reports on the long-term results of tricuspid valve replacement with bioprosthetic valves are evaluated by serial Doppler echocardiography. Methods. Between September 1979 and December 1993, 95 patients underwent tricuspid valve replacement with bioprosthetic valves at our facility. Sixty patients who underwent serial Doppler echocardiographic examination at intervals of at least 2 years after operation were included in the final analysis. These patients were followed up from 1.5 to 13.0 years (mean 5.8 +/- 2.5). Results. The actuarial rates of freedom from bioprosthetic valve stenosis and regurgitation at 10 years were 46% and 51%, respectively. The prevalence of bioprosthetic valve stenosis and regurgitation increased progressively in a linear manner beginning 1 or 2 years after tricuspid valve replacement. Right heart failure developed during follow up in 20 of the 25 patients with bioprosthetic valve dysfunction. Conclusions. The long-term durability of bioprosthetic valves in the tricuspid position was substantially lower in our study than that reported in previous studies. Tricuspid bioprosthetic valve dysfunction increased progressively in a linear manner beginning 1 to 2 years after tricuspid valve replacement.
引用
收藏
页码:1693 / 1697
页数:5
相关论文
共 50 条
  • [31] DEGENERATION AND CALCIFICATION OF BIOPROSTHETIC CARDIAC VALVES - BIOPROSTHETIC TRICUSPID-VALVE IMPLANTATION IN SHEEP
    BARNHART, GR
    JONES, M
    ISHIHARA, T
    ROSE, DM
    CHAVEZ, AM
    FERRANS, VJ
    AMERICAN JOURNAL OF PATHOLOGY, 1982, 106 (01): : 136 - 139
  • [32] CONTINUOUS-WAVE DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF SEVERE TRICUSPID REGURGITATION
    MINAGOE, S
    TEI, C
    KISANUKI, A
    NATSUGOE, K
    SHIBATA, K
    YUZUDO, T
    KAWAZOE, Y
    TANAKA, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1987, 51 (07): : 835 - 835
  • [33] PULSED DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF THE TRICUSPID REGURGITATION IN PEDIATRIC-PATIENTS
    FUKAYA, T
    YOSHIKAWA, J
    YOSHIDA, K
    YAMAKAWA, M
    TOMITA, Y
    BABA, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1985, 49 (08): : 822 - 822
  • [34] Exploring Tricuspid Regurgitation in Treating Degenerated Bioprosthetic Aortic Valves
    Kornowski, Ran
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (12) : 1161 - 1163
  • [35] Mid-term clinical and echocardiographic follow up of patients with CarboMedics® valves in the tricuspid position
    Shapira, Y
    Nili, M
    Hirsch, R
    Vaturi, M
    Vidne, B
    Sagie, A
    JOURNAL OF HEART VALVE DISEASE, 2000, 9 (03): : 396 - 402
  • [36] RETURN OF THE TRICUSPID VALVE THROMBUS IN NATIVE AND SUBSEQUENT BIOPROSTHETIC VALVES
    Lee, Bridget G.
    Brider, Jamarcus
    Doty, Brandon
    Younis, Naveed
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 3692 - 3692
  • [37] DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF HANCOCK AND BJORK-SHILEY PROSTHETIC VALVES
    SAGAR, KB
    WANN, LS
    PAULSEN, WHJ
    ROMHILT, DW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (03) : 681 - 687
  • [38] DOPPLER-ECHOCARDIOGRAPHIC EVALUATION OF THE STRUCTURE AND FUNCTION OF PROSTHETIC CARDIAC VALVES
    FLACHSKAMPF, FA
    JOB, FP
    FRANKE, S
    HANRATH, P
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1991, 116 (27) : 1069 - 1075
  • [39] PULSED DOPPLER AND ECHOCARDIOGRAPHY OF NORMAL AND DYSFUNCTIONING BIOPROSTHETIC VALVES
    ALAM, M
    ROSMAN, HS
    LAKIER, JB
    KEMP, SR
    KHAJA, F
    MAGILLIGAN, DJ
    STEIN, PD
    CIRCULATION, 1986, 74 (04) : 390 - 390
  • [40] PATHOLOGICAL CORRELATIONS OF TRANSESOPHAGEAL ECHOCARDIOGRAPHIC FINDINGS IN DEGENERATED BIOPROSTHETIC VALVES
    CHAN, KL
    WALLEY, VM
    CIRCULATION, 1990, 82 (04) : 44 - 44