Serial Doppler echocardiographic evaluation of bioprosthetic valves in the tricuspid position

被引:12
|
作者
Kobayashi, Y
Nagata, S
Ohmori, F
Eishi, K
Nakano, K
Miyatake, K
机构
[1] NATL CARDIOVASC CTR,DEPT INTERNAL MED,DIV CARDIOL,SUITA,OSAKA 565,JAPAN
[2] NATL CARDIOVASC CTR,DEPT INTERNAL MED,DIV CARDIOVASC SURG,SUITA,OSAKA 565,JAPAN
关键词
D O I
10.1016/0735-1097(96)00056-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study sought to evaluate bioprosthetic valve dysfunction in the tricuspid position by serial Doppler echocardiography. Background. Few reports on the long-term results of tricuspid valve replacement with bioprosthetic valves are evaluated by serial Doppler echocardiography. Methods. Between September 1979 and December 1993, 95 patients underwent tricuspid valve replacement with bioprosthetic valves at our facility. Sixty patients who underwent serial Doppler echocardiographic examination at intervals of at least 2 years after operation were included in the final analysis. These patients were followed up from 1.5 to 13.0 years (mean 5.8 +/- 2.5). Results. The actuarial rates of freedom from bioprosthetic valve stenosis and regurgitation at 10 years were 46% and 51%, respectively. The prevalence of bioprosthetic valve stenosis and regurgitation increased progressively in a linear manner beginning 1 or 2 years after tricuspid valve replacement. Right heart failure developed during follow up in 20 of the 25 patients with bioprosthetic valve dysfunction. Conclusions. The long-term durability of bioprosthetic valves in the tricuspid position was substantially lower in our study than that reported in previous studies. Tricuspid bioprosthetic valve dysfunction increased progressively in a linear manner beginning 1 to 2 years after tricuspid valve replacement.
引用
收藏
页码:1693 / 1697
页数:5
相关论文
共 50 条
  • [1] SERIAL DOPPLER-ECHOCARDIOGRAPHIC EVALUATION OF BIOPROSTHETIC VALVES IN THE TRICUSPID POSITION
    KOBAYASHI, Y
    NAGATA, S
    OHMORI, F
    EISHI, K
    NAKANO, K
    MIYATAKE, K
    CIRCULATION, 1995, 92 (08) : 2936 - 2936
  • [2] DOPPLER ECHOCARDIOGRAPHIC CHARACTERISTICS OF PROSTHETIC VALVES IN THE TRICUSPID POSITION
    PYE, M
    BAIN, W
    WEERASANA, N
    HUTTON, I
    COBBE, SM
    BRITISH HEART JOURNAL, 1989, 61 (01): : 92 - 92
  • [3] DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF STENOTIC BIOPROSTHETIC AORTIC VALVES
    OTTO, CM
    PEARLMAN, AS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 825 - 826
  • [4] DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF 3 MODELS OF BIOPROSTHETIC MITRAL-VALVES
    BONADUCE, D
    PETRETTA, M
    BREGLIO, R
    CONFORTI, G
    MONTEMURRO, MV
    COVINO, E
    MORGANO, G
    BIANCHI, V
    JOURNAL OF CARDIOVASCULAR TECHNOLOGY, 1990, 9 (01): : 25 - 30
  • [5] DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF NORMAL MEDTRONIC INTACT AORTIC BIOPROSTHETIC VALVES
    ETIENNE, Y
    JOBIC, Y
    GENET, L
    BARRA, JA
    BOSCHAT, J
    GILARD, M
    PENTHER, P
    BLANC, JJ
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1990, 83 (14): : 2039 - 2044
  • [6] DOPPLER ECHOCARDIOGRAPHIC CHARACTERISTICS OF NORMAL AND DYSFUNCTIONING PROSTHETIC VALVES IN THE TRICUSPID AND MITRAL POSITION
    PYE, M
    WEERASANA, N
    BAIN, WH
    HUTTON, I
    COBBE, SM
    BRITISH HEART JOURNAL, 1990, 63 (01): : 41 - 44
  • [7] DOPPLER AND ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND DYSFUNCTIONING BIOPROSTHETIC VALVES
    ALAM, M
    ROSMAN, HS
    LAKIER, JB
    KEMP, S
    KHAJA, F
    HAUTAMAKI, K
    MAGILLIGAN, DJ
    STEIN, PD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) : 851 - 858
  • [8] Doppler echocardiographic evaluation of St. Jude Medical valves in the tricuspid position - Criteria for normal and abnormal valve function
    Sezai, A
    Shiono, M
    Akiyama, K
    Orime, Y
    Hata, H
    Yagi, S
    Tsukamoto, S
    Nakata, K
    Hata, M
    Negishi, N
    Sezai, Y
    JOURNAL OF CARDIOVASCULAR SURGERY, 2001, 42 (03): : 303 - 309
  • [9] DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF 3 MODELS OF PROSTHETIC VALVES IN THE AORTIC POSITION
    BONADUCE, D
    PETRETTA, M
    BREGLIO, R
    CONFORTI, G
    MONTEMURRO, MV
    COVINO, E
    MORGANO, G
    BIANCHI, V
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1991, 5 (02): : 98 - 102
  • [10] EFFECT OF RESPIRATION ON DOPPLER PARAMETERS OF NORMAL TRICUSPID PORCINE BIOPROSTHETIC VALVES
    COSYNS, B
    VANCAMP, G
    FRIART, A
    VANDENBOSSCHE, JL
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1995, 11 (01): : 55 - 58