CDS4C: A Novel CDS ASIC for a Multi-Readout X-ray CCD with a 0.032% INL

被引:0
|
作者
Lu, Bo [1 ,2 ,3 ]
Chen, Yong [1 ]
Yang, Yanji [1 ]
Cui, Weiwei [1 ]
Liu, Hainan [2 ]
Zhou, Yumei [2 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophys, Beijing, Peoples R China
[2] Chinese Acad Sci, Inst Microelect, Beijing, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
HXMT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents the development of a four-channel correlated double sampling (CDS) ASIC, named CDS4C, targeting the readout of a type of multi-readout swept charge device (SCD) for applications in the fields of both Xray spectroscopy and imaging. Compared with conventional CDS architecture based on clamping technique, the innovation of the CDS4C ASIC is that it not only moves the clamping switch out of the signal path but also omits the sampling switch, eliminating the nonlinearity and thermal noise introduced by the these switches. Besides, it is implemented in a fully differential topology which suppresses the second-order harmonic distortion, improving the linearity further more. A theoretical noise analysis taking into consideration of the limited bandwidth of the operational-amplifier (OPA) highly coincides with the simulation results. A prototype of the CDS4C ASIC is fabricated with GlobalFoundries 0.35 mu m CMOS process, the preliminary experimental results show that, within the effective input dynamic range of 0 similar to 20mV which is equivalent to a wide range of soft X-ray energy band from 0 to 18.25keV, 0.032% integral nonlinearity (INL) and 35.5 mu V input-referred readout noise are achieved under 200kHz pixel rate with 8x gain, while the total power consumption is only 8.8m W from a single 3.3V supply voltage.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] High rate X-ray imaging using multi-GEM detectors with a novel readout design
    Bachmann, S
    Kappler, S
    Ketzer, B
    Müller, T
    Ropelewski, L
    Sauli, F
    Schulte, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2): : 104 - 108
  • [22] Terbium-doped carbon dots (Tb-CDs) as a novel contrast agent for efficient X-ray attenuation
    Molkenova, Anara
    Serik, Lazzat
    Ramazanova, Alina
    Zhumanova, Kamila
    Duisenbayeva, Bakyt
    Zhussupbekova, Ainur
    Zhussupbekov, Kuanysh
    Shvets, Igor V.
    Kim, Ki Su
    Han, Dong-Wook
    Atabaev, Timur Sh.
    RSC ADVANCES, 2023, 13 (22) : 14974 - 14979
  • [23] Valence band offset at the CdS/Cu2ZnSnS4 interface probed by x-ray photoelectron spectroscopy
    Santoni, A.
    Biccari, F.
    Malerba, C.
    Valentini, M.
    Chierchia, R.
    Mittiga, A.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (17)
  • [24] Design and Characterizations of the Radiation-Hardened XCR4C ASIC for X-Ray CCDs for Space Astronomical Applications
    Lu, Bo
    Li, Bo
    Huo, Jia
    Chen, Yong
    Zhao, Wenxin
    Gao, Jiantou
    Wang, Chunlin
    Liu, Hainan
    Luo, Jiajun
    Zhou, Yumei
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (06) : 1175 - 1184
  • [25] Direct measurement of band offset at the interface between CdS and Cu2ZnSnS4 using hard X-ray photoelectron spectroscopy
    Tajima, Shin
    Kataoka, Keita
    Takahashi, Naoko
    Kimoto, Yasuji
    Fukano, Tatsuo
    Hasegawa, Masaki
    Hazama, Hirofumi
    APPLIED PHYSICS LETTERS, 2013, 103 (24)
  • [26] X-RAY STUDY OF DISORDERED ZNS-CDS AND ZNS-ZNSE CRYSTALS OF MIXED STRUCTURES 10H, 6H AND 3C
    PALOSZ, B
    PRZEDMOJSKI, J
    ACTA PHYSICA POLONICA A, 1975, A 47 (04) : 439 - 445
  • [27] Design and Characterizations of the Radiation-Hardened XCR4C ASIC for X-Ray CCDs for Space Astronomical Applications (vol 67, pg 1175, 2020)
    Lu, Bo
    Li, Bo
    Huo, Jia
    Chen, Yong
    Zhao, Wenxin
    Gao, Jiantou
    Wang, Chunlin
    Liu, Hainan
    Luo, Jiajun
    Zhou, Yumei
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (02) : 192 - 192
  • [28] DOSE CALCULATION OF RU-106 OPHTHALMIC PLAQUES WITH MULTI SLICE X-RAY CT PAGAT GEL DOSIMETRY AND MCNP4C CODE
    Azma, Z.
    Zahmatkesh, M. H.
    Jaberi, R.
    Reza, A. Mahmood
    Bagheri, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S211 - S211
  • [29] X-RAY CRYSTAL-STRUCTURE ANALYSIS OF HEPTACYCLIC MOLECULE C28H39O4BR CONTAINING A NOVEL CAGE SYSTEM
    TURNER, JA
    MCEWEN, RS
    ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE, 1974, 30 (SEP15): : 2151 - 2156
  • [30] THE FORMATION AND X-RAY STRUCTURE OF A NOVEL (1IND+4MP-C4H8O3) TRISPIRO ADDUCT FROM CYCLOHEPT[B]INDOLES AND METHYL PROPIOLATE
    CHOI, MCK
    CHAN, DTW
    LETCHER, RM
    CHEUNG, KK
    JOURNAL OF CHEMICAL RESEARCH-S, 1992, (10): : 322 - 323