Comparison between latest generation steroid-eluting screw-in and tined leads. Long term follow-up

被引:0
|
作者
Menozzi, C
机构
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An Italian multicenter study was conducted on 180 patients in order to evaluate the long-term performances of latest generation steroid-eluting, screw-in vs. tined leads in the atrium (A) and in the ventricle (V). Single and dual-chamber Medtronic Thera pacemakers were implanted with 235 Medtronic Capsure Z tined leads (111 A and 124 V) and 100 Medtronic Capsure Fix screw-in leads (48 A and 52 V). Follow-up visits at 24 hour, 1, 3, 6, and 12 month post-implant were performed. Tined leads showed a significantly lower threshold (at 1.6 V) and higher pacing impedance than screw-in leads in both chambers. The sensing values, however, were similar. At the 1 year follow-up, both leads gave good electric performances thus permitting low energy stimulation. No significant differences were found between bipolar and unipolar models. In a small percentage of patients (12 patients) implanted with screw-in leads, we compared the acute/chronic pacing thresholds and impedance values recorded either in the right ventricular outflow tract or in the right apex and we found no statistical difference between the two examined pacing sites.
引用
收藏
页码:389 / 393
页数:5
相关论文
共 50 条
  • [11] COMPARISON OF 2ND AND 3RD-GENERATION STEROID-ELUTING PACING LEADS
    BERSOHN, MM
    PANZER, SB
    CLINICAL RESEARCH, 1994, 42 (01): : A99 - A99
  • [12] Five-year follow-up of a bipolar steroid-eluting ventricular pacing lead
    Schwaab, B
    Fröhlig, G
    Berg, M
    Schwerdt, H
    Schieffer, H
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (08): : 1226 - 1228
  • [13] Comparison of pacing thresholds of steroid eluting and steroid free ventricular leads during three years follow-up
    Yesil, M
    Bayata, S
    Postaci, N
    Eksi, K
    Susam, I
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 795 - 797
  • [14] STEROID-ELUTING LEADS - 4-YEAR-FOLLOW-UP OF PACING THRESHOLD, IMPEDANCE, AND INTRACARDIAC VENTRICULAR SIGNAL
    SCHUCHERT, A
    KUCK, KH
    HERZ KREISLAUF, 1993, 25 (09): : 289 - 291
  • [15] Long-term performance of transvenous, steroid-eluting, high impedance, passive-fixation ventricular pacing leads
    Yeh, KH
    Wang, CC
    Wen, MS
    Chou, CC
    Yeh, SJ
    Wu, DL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (10): : 1399 - 1404
  • [16] Long-term performance of screw-in atrial pacing leads: A Randomized comparison of J-shaped and straight leads
    Luria, D
    Bar-Lev, D
    Gurevitz, S
    Granit, H
    Rotstein, Z
    Eldar, M
    Glikson, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09): : 898 - 902
  • [17] LONG-TERM FOLLOW-UP OF TRANSVENOUS ENDOCARDIAL ATRIAL LEADS
    KRUSE, IM
    RYDEN, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 702 - 702
  • [18] Steroid elimination during long term follow-up in hand transplantation
    Ravindra, Kadiyala
    Kaufman, Christina
    Buell, Joseph
    Marvin, Michael
    Nagubandi, Ravi
    Ildstad, Suzanne
    Blair, Brenda
    Briedenbach, Warren
    AMERICAN JOURNAL OF TRANSPLANTATION, 2008, 8 : 490 - 490
  • [19] Long-term follow-up of lumbar epidural steroid injections
    Hopwood, MB
    Abram, SE
    ANESTHESIOLOGY, 1998, 89 (3A) : U905 - U905
  • [20] Safety and efficacy of drug-eluting stents in the long term follow-up
    Urina-Triana, M.
    Rondon, M.
    Dennis, R.
    EUROPEAN HEART JOURNAL, 2012, 33 : 559 - 559