Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters

被引:58
|
作者
Hsu, Shih-Ming
Yeh, Shann-Horng
Lin, Meei-Shiow
Chen, Wei-Li
机构
[1] Natl Yang Ming Univ, Dept Med Radiat Technol, Taipei 112, Taiwan
[2] Tzu Chi Coll Technol, Dept Radiol Technol, Iwaki, Fukushima 970, Japan
[3] Inst Nucl Energy Res, Longtan 325, Taiwan
关键词
D O I
10.1093/rpd/nci510
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The radiophotoluminescent glass dosemeter (RPLGD) system is applicable for measurement of radiation dose of X rays and gamma rays by using radiophotoluminescent glass (silver-activated phosphate glass). When the radiophotoluminescent glass is exposed to ionizing radiation, stable luminescent centres are created. During pulsed ultraviolet laser excitation (337.1 nm) in the reader, the centres emit a radiation induced orange fluorescent light (600-700 nm). This phenomenon is called radiophotoluminescence. This study compared the RPLGD system with lithium fluoride (LiF) thermoluminescence dosimetry system and the results of the study revealed that the RPLGD had not only good basic characteristics for reproducibility of readout value, dose linearity, energy dependence and fading, but also infinite repeatable measurements and could be one of the most important radiation dose measurement instruments.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [41] Calculated energy response correction factors for LiF thermoluminescent dosemeters employed in the seventh EULEP dosimetry intercomparison
    Zoetelief, J
    Jansen, JTM
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08): : 1491 - 1504
  • [42] Effect of angular response properties of personal dosemeters on the estimation of effective dose using two dosemeters
    Kim, CH
    Reece, WD
    RADIATION PROTECTION DOSIMETRY, 2001, 93 (03) : 215 - 221
  • [43] SUB-STANDARD DOSEMETERS
    WOOD, RG
    SUTHERLAND, WH
    BRITISH JOURNAL OF RADIOLOGY, 1955, 28 (329): : 283 - 284
  • [44] The energy correction factor of LiF thermoluminescent dosemeters in megavoltage electron beams: Monte Carlo simulations and experiments
    Mobit, PN
    Nahum, AE
    Mayles, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06): : 979 - 993
  • [45] INTERCOMPARISON OF EYE LENS DOSEMETERS
    Behrens, R.
    Hupe, O.
    Busch, F.
    Denk, J.
    Engelhardt, J.
    Gunther, K.
    Hoedlmoser, H.
    Jordan, M.
    Strohmaier, J.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (01) : 6 - 12
  • [46] PERFORMANCE TEST RESULTS OF ACTIVE PERSONAL DOSEMETERS (APDS) USED IN NUCLAER POWER PLANT IN KOREA: A COMPARISON WITH THERMO-LUMINESCENCE DOSEMETERS (TLDS)
    Lee, YoungJu
    Won, Yuho
    Kang, Kidoo
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 431 - 437
  • [47] Effects of high ambient temperature on glow-peak fading properties of Lif:Mg,Ti thermoluminescent dosemeters
    Harvey, John A.
    Kearfott, Kimberlee J.
    RADIATION PROTECTION DOSIMETRY, 2012, 149 (02) : 109 - 115
  • [48] DOSE MEASUREMENT OF MIXED BETA AND GAMMA FIELDS OF A HOMOGENEOUSLY DISTRIBUTED ISOTOPE USING POWDER AND SOLID THERMOLUMINESCENT DOSEMETERS
    SHERMAN, AA
    RUDIN, S
    MCDOUGAL.RS
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (02): : 376 - &
  • [49] COMPARISON OF THE NEUTRON ENERGY RESPONSE OF TWO DIFFERENT TLD ALBEDO DOSEMETERS
    Freitas, B. M.
    da Silva, A. X.
    Pereira, W. W.
    Mauricio, C. L. P.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 240 - 244
  • [50] An Inter-Comparison of Passive Dosemeters for Terrestrial Gamma Radiation Measurements
    Ding, Yanqiu
    Wang, Kaiyi
    Gao, Pin
    Hu, Aiying
    Guo, Wen
    Han, Yanqing
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (16) : 1205 - 1209