Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters

被引:58
|
作者
Hsu, Shih-Ming
Yeh, Shann-Horng
Lin, Meei-Shiow
Chen, Wei-Li
机构
[1] Natl Yang Ming Univ, Dept Med Radiat Technol, Taipei 112, Taiwan
[2] Tzu Chi Coll Technol, Dept Radiol Technol, Iwaki, Fukushima 970, Japan
[3] Inst Nucl Energy Res, Longtan 325, Taiwan
关键词
D O I
10.1093/rpd/nci510
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The radiophotoluminescent glass dosemeter (RPLGD) system is applicable for measurement of radiation dose of X rays and gamma rays by using radiophotoluminescent glass (silver-activated phosphate glass). When the radiophotoluminescent glass is exposed to ionizing radiation, stable luminescent centres are created. During pulsed ultraviolet laser excitation (337.1 nm) in the reader, the centres emit a radiation induced orange fluorescent light (600-700 nm). This phenomenon is called radiophotoluminescence. This study compared the RPLGD system with lithium fluoride (LiF) thermoluminescence dosimetry system and the results of the study revealed that the RPLGD had not only good basic characteristics for reproducibility of readout value, dose linearity, energy dependence and fading, but also infinite repeatable measurements and could be one of the most important radiation dose measurement instruments.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [21] Individual monitoring with BeOSL dosemeters: New dosemeters for extremity and area dosimetry
    Hoedlmoser, H.
    Greiter, M.
    Bandalo, V
    Broenner, J.
    Kleinau, P.
    Haninger, T.
    Mende, E.
    Emmerl, M.
    Scheubert, P.
    Esser, R.
    Figel, M.
    RADIATION MEASUREMENTS, 2020, 132
  • [22] DEVELOPMENT OF CONFOCAL LASER MICROSCOPE SYSTEM FOR EXAMINATION OF MICROSCOPIC CHARACTERISTICS OF RADIOPHOTOLUMINESCENCE GLASS DOSEMETERS
    Maki, Daisuke
    Ishii, Tetsuya
    Sato, Fuminobu
    Kato, Yushi
    Yamamoto, Takayoshi
    Iida, Toshiyuki
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 222 - 225
  • [23] Study on the response of thermoluminescent dosemeters to synchrotron radiation: experimental method and Monte Carlo calculations
    Bakshi, A. K.
    Chatterjee, S.
    Selvam, T. Palani
    Dhabekar, B. S.
    RADIATION PROTECTION DOSIMETRY, 2010, 140 (02) : 137 - 146
  • [24] Thermoluminescent spectra of rare earth doped MgB4O7 dosemeters
    Karali, T
    Rowlands, AP
    Prokic, M
    Townsend, PD
    Halmagean, E
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 333 - 336
  • [25] Thermoluminescent spectra of rare earth doped MgB4O7 dosemeters
    Karali, T
    Rowlands, AP
    Prokic, M
    Townsend, PD
    Halmagean, E
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 333 - 336
  • [26] A rotational calibration method using thermoluminescent dosemeters for dose determination in computed tomography beams
    Maia, Ana F.
    Caldas, Linda V. E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (01): : 107 - 110
  • [27] SIGNALING RADIATION DOSEMETERS
    BROWN, DP
    HEALTH PHYSICS, 1965, 11 (08): : 829 - +
  • [28] Use of composites of topaz-glass as TSEE and TL dosemeters
    de Magalhaes, C. M. S.
    Souza, D. N.
    Caldas, L. V. E.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 323 - 326
  • [29] SILICON DETECTORS AND DOSEMETERS
    PARKER, RP
    PHYSICS IN MEDICINE AND BIOLOGY, 1965, 10 (02): : 286 - &
  • [30] Fading time and irradiation dose estimation from thermoluminescent dosemeters using glow curve deconvolution
    Theinert, R.
    Kroeninger, K.
    Luetfring, A.
    Mender, S.
    Mentzel, F.
    Walbersloh, J.
    RADIATION MEASUREMENTS, 2018, 108 : 20 - 25