Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters

被引:58
|
作者
Hsu, Shih-Ming
Yeh, Shann-Horng
Lin, Meei-Shiow
Chen, Wei-Li
机构
[1] Natl Yang Ming Univ, Dept Med Radiat Technol, Taipei 112, Taiwan
[2] Tzu Chi Coll Technol, Dept Radiol Technol, Iwaki, Fukushima 970, Japan
[3] Inst Nucl Energy Res, Longtan 325, Taiwan
关键词
D O I
10.1093/rpd/nci510
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The radiophotoluminescent glass dosemeter (RPLGD) system is applicable for measurement of radiation dose of X rays and gamma rays by using radiophotoluminescent glass (silver-activated phosphate glass). When the radiophotoluminescent glass is exposed to ionizing radiation, stable luminescent centres are created. During pulsed ultraviolet laser excitation (337.1 nm) in the reader, the centres emit a radiation induced orange fluorescent light (600-700 nm). This phenomenon is called radiophotoluminescence. This study compared the RPLGD system with lithium fluoride (LiF) thermoluminescence dosimetry system and the results of the study revealed that the RPLGD had not only good basic characteristics for reproducibility of readout value, dose linearity, energy dependence and fading, but also infinite repeatable measurements and could be one of the most important radiation dose measurement instruments.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [1] Dosimertry characteristics and performance comparisons: Environmental radiophotoluminescent glass dosemeters versus thermoluminescent dosemeters
    Lee, J. H.
    Lin, M. S.
    Hsu, S. M.
    Chen, I. J.
    Chen, W. L.
    Wang, C. F.
    RADIATION MEASUREMENTS, 2009, 44 (01) : 86 - 91
  • [2] DEVELOPMENT AND APPLICATIONS OF THERMOLUMINESCENT DOSEMETERS
    HALL, RM
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (04): : 623 - &
  • [3] AN AUTORANGING READER FOR THERMOLUMINESCENT DOSEMETERS
    CASBOLT, PN
    CLIFF, KD
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (06): : 511 - &
  • [4] ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY
    Silva, E. H.
    Knezevic, Z.
    Struelens, L.
    Covens, P.
    Ueno, S.
    Vanhavere, F.
    Buls, N.
    RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 208 - 212
  • [5] LITHIUM FLUORIDE PLASTIC DOSEMETERS FOR THERMOLUMINESCENT DOSIMETRY
    BJARNGARD, BE
    MCCALL, RC
    BERSTEIN, IA
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 149 - +
  • [6] PROTON DEPTH DOSE DOSIMETRY WITH THERMOLUMINESCENT DOSEMETERS
    HARDY, KA
    ALLEN, SJ
    MITCHELL, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (02): : 299 - &
  • [7] ISOTOPIC EFFECT IN LITHIUM FLUORIDE THERMOLUMINESCENT DOSEMETERS
    ATTIX, FH
    PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (01): : 147 - &
  • [8] Application of the thermoluminescent dosemeters for the measurement of low level background
    Stochioiu, Ana I.
    Sahagia, Maria C.
    Mihai, Felicia S.
    Tudor, Ion L.
    Lupescu, Henrieta
    SIX INTERNATIONAL CONFERENCE OF THE BALKAN PHYSICAL UNION, 2007, 899 : 413 - +
  • [9] EXPERIENCE IN USE OF THERMOLUMINESCENT DOSEMETERS FOR DOSE CONTROL PURPOSES
    PRESTON, HE
    CLIFTON, JJ
    HALLETT, CD
    HEALTH PHYSICS, 1970, 19 (01): : 90 - +
  • [10] Entrance and exit dose measurements with semiconductors and thermoluminescent dosemeters: A comparison of methods and in vivo results
    Loncol, T
    Greffe, JL
    Vynckier, S
    Scalliet, P