Correlation between fractional exhaled nitric oxide and sputum eosinophilia in exacerbations of COPD

被引:23
|
作者
Gao, Jie [1 ]
Zhang, Min [2 ]
Zhou, Liqin [1 ]
Yang, Xing [1 ]
Wu, Haigui [1 ]
Zhang, Jianfang [1 ]
Wu, Feng [1 ]
机构
[1] Guangzhou Med Univ, Dept Resp Med, Peoples Hosp 3, 1 Xuebei Ave, Huizhou 516002, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Internal Med Cardiovasc Dept, Peoples Hosp 3, Huizhou, Peoples R China
关键词
fractional exhaled nitric oxide; eosinophils in induced sputum; blood eosinophil percentage; chronic obstructive pulmonary disease; AIRWAY EOSINOPHILIA; ASTHMA;
D O I
10.2147/COPD.S134998
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Measurements of eosinophils in induced sputum and fractional exhaled nitric oxide (FeNO) are noninvasive biomarkers for assessing airway inflammation phenotypes in chronic obstructive pulmonary disease (COPD). Nevertheless, the clinical application of the correlation between FeNO levels and sputum eosinophilia is controversial. The study aimed to investigate the correlation and predictive relationship between FeNO levels and sputum eosinophils in patients with COPD exacerbation. It also examined the relationship between FeNO levels and blood eosinophil percentage. Methods: A total of 163 patients with COPD exacerbation were included in the cross-sectional study. All patients underwent the following on the same day: FeNO test, spirometry, bronchodilator reversibility test, induced sputum, and routine blood test. They were classified as eosinophilic group or noneosinophilic group based on sputum eosinophilic percentage (>= 2.5%)/FeNO levels (>= 32 parts per billion [ppb]). Results: FeNO levels and blood eosinophilic percentage were higher in patients with sputum eosinophilia (n=62) compared to those without (31.35 ppb versus 21.43 ppb, P=0.015; 2.71% versus 0.98%, P<0.0001, respectively). Sputum eosinophilic percentage was higher with raised FeNO (n=34) compared to those with FeNO <32 ppb (5.12% versus 3.12%, P=0.007). Eosinophils in induced sputum correlated with both FeNO levels (rho=0.221, P=0.005) and blood eosinophilic percentage (rho=0.399, P < 0.001). There was no relationship between FeNO and blood eosinophilic percentage. Blood eosinophilic percentage was predictive of sputum eosinophilia (95% confidence interval [CI] =0.65-0.81, P. 0.001) at a cutoff point of 0.65% (sensitivity =73%, specificity = 61.3%). FeNO levels were predictive of sputum eosinophilia (95% CI =0.53-3,071, P=0.012) at a cutoff point of 17.5 ppb (sensitivity =65.1%, specificity =56.4%). Conclusion: The clinical relevance of this study provides evidence that inflammatory biomarkers, including sputum eosinophilic percentage, FeNO level, and blood eosinophilic percentage, can be used to positively diagnose eosinophilic COPD. The FeNO level and blood eosinophilic counts/percentage, which determine an optimal cutoff for sputum eosinophilia, need more studies.
引用
收藏
页码:1287 / 1293
页数:7
相关论文
共 50 条
  • [31] Association between fractional exhaled nitric oxide, sputum induction and peripheral blood eosinophil in uncontrolled asthma
    Jie Gao
    Feng Wu
    Allergy, Asthma & Clinical Immunology, 14
  • [32] Association between fractional exhaled nitric oxide, sputum induction and peripheral blood eosinophil in uncontrolled asthma
    Gao, Jie
    Wu, Feng
    ALLERGY ASTHMA AND CLINICAL IMMUNOLOGY, 2018, 14
  • [33] Clinical and inflammatory features of asthma with dissociation between fractional exhaled nitric oxide and eosinophils in induced sputum
    Crespo, Astrid
    Giner, Jordi
    Torrejon, Montserrat
    Belda, Alicia
    Mateus, Eder
    Granel, Carmen
    Torrego, Alfons
    Ramos-Barbon, David
    Plaza, Vicente
    JOURNAL OF ASTHMA, 2016, 53 (05) : 459 - 464
  • [34] Domiciliary Fractional Exhaled Nitric Oxide and Spirometry in Monitoring Asthma Control and Exacerbations
    Wang, Ran
    Usmani, Omar S.
    Chung, Kian Fan
    Sont, Jacob
    Simpson, Andrew
    Bonini, Matteo
    Honkoop, Persijn J.
    Fowler, Stephen J.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE, 2023, 11 (06): : 1787 - +
  • [35] DOMICILIARY FRACTIONAL EXHALED NITRIC OXIDE AND SPIROMETRY IN PREDICTING ASTHMA CONTROL AND EXACERBATIONS
    Wang, R.
    Usmani, O. S.
    Chung, K. F.
    Sont, J.
    Simpson, A.
    Bonini, M.
    Honkoop, P.
    Fowler, S. J.
    THORAX, 2022, 77 : A73 - A74
  • [36] Comparison of Fractional Nitric Oxide in Exhaled Breath in bronchial asthma and COPD
    Mittal, Saurabh
    Mohan, Anant
    Madan, Karan
    Hadda, Vijay
    Guleria, Randeep
    Khilnani, Gopi Chand
    Pandey, Ravindra Mohan
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [37] Exhaled nitric oxide and induced sputum analysis as markers of airway inflammation in subjects with COPD
    Silkoff, PE
    Martin, D
    Pak, J
    Martin, RJ
    CHEST, 2000, 117 (05) : 281S - 281S
  • [38] Relationship between fraction of exhaled nitric oxide and peripheral eosinophilia in asthma
    Afriyie-Mensah, Jane S.
    Domoyeri, Philemon
    Antwi-Boasiako, Charles
    Aryee, Robert
    Dankwah, Gifty B.
    Ntiamoah, Mabel
    Dzudzor, Bartholomew
    Kusi-Mensah, Yaw
    Hayfron-Benjamin, Charles F.
    ANNALS OF MEDICINE, 2024, 56 (01)
  • [39] DISCORDANCE BETWEEN SPUTUM EOSINOPHILS AND EXHALED NITRIC OXIDE IN CHILDREN WITH ASTHMA
    Fleming, L.
    Tsartsali, L.
    Wilson, N.
    Regamey, N.
    Bossley, C.
    Bush, A.
    THORAX, 2008, 63 : A34 - A34
  • [40] USING FRACTIONAL EXHALED NITRIC OXIDE TO GUIDE TREATMENT IN SYSTEMIC DISEASES WITH AIRWAY EOSINOPHILIA
    Livingston, L.
    Schwartz, L.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2015, 115 (05) : A95 - A95