Correlation between fractional exhaled nitric oxide and sputum eosinophilia in exacerbations of COPD

被引:23
|
作者
Gao, Jie [1 ]
Zhang, Min [2 ]
Zhou, Liqin [1 ]
Yang, Xing [1 ]
Wu, Haigui [1 ]
Zhang, Jianfang [1 ]
Wu, Feng [1 ]
机构
[1] Guangzhou Med Univ, Dept Resp Med, Peoples Hosp 3, 1 Xuebei Ave, Huizhou 516002, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Internal Med Cardiovasc Dept, Peoples Hosp 3, Huizhou, Peoples R China
关键词
fractional exhaled nitric oxide; eosinophils in induced sputum; blood eosinophil percentage; chronic obstructive pulmonary disease; AIRWAY EOSINOPHILIA; ASTHMA;
D O I
10.2147/COPD.S134998
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Measurements of eosinophils in induced sputum and fractional exhaled nitric oxide (FeNO) are noninvasive biomarkers for assessing airway inflammation phenotypes in chronic obstructive pulmonary disease (COPD). Nevertheless, the clinical application of the correlation between FeNO levels and sputum eosinophilia is controversial. The study aimed to investigate the correlation and predictive relationship between FeNO levels and sputum eosinophils in patients with COPD exacerbation. It also examined the relationship between FeNO levels and blood eosinophil percentage. Methods: A total of 163 patients with COPD exacerbation were included in the cross-sectional study. All patients underwent the following on the same day: FeNO test, spirometry, bronchodilator reversibility test, induced sputum, and routine blood test. They were classified as eosinophilic group or noneosinophilic group based on sputum eosinophilic percentage (>= 2.5%)/FeNO levels (>= 32 parts per billion [ppb]). Results: FeNO levels and blood eosinophilic percentage were higher in patients with sputum eosinophilia (n=62) compared to those without (31.35 ppb versus 21.43 ppb, P=0.015; 2.71% versus 0.98%, P<0.0001, respectively). Sputum eosinophilic percentage was higher with raised FeNO (n=34) compared to those with FeNO <32 ppb (5.12% versus 3.12%, P=0.007). Eosinophils in induced sputum correlated with both FeNO levels (rho=0.221, P=0.005) and blood eosinophilic percentage (rho=0.399, P < 0.001). There was no relationship between FeNO and blood eosinophilic percentage. Blood eosinophilic percentage was predictive of sputum eosinophilia (95% confidence interval [CI] =0.65-0.81, P. 0.001) at a cutoff point of 0.65% (sensitivity =73%, specificity = 61.3%). FeNO levels were predictive of sputum eosinophilia (95% CI =0.53-3,071, P=0.012) at a cutoff point of 17.5 ppb (sensitivity =65.1%, specificity =56.4%). Conclusion: The clinical relevance of this study provides evidence that inflammatory biomarkers, including sputum eosinophilic percentage, FeNO level, and blood eosinophilic percentage, can be used to positively diagnose eosinophilic COPD. The FeNO level and blood eosinophilic counts/percentage, which determine an optimal cutoff for sputum eosinophilia, need more studies.
引用
收藏
页码:1287 / 1293
页数:7
相关论文
共 50 条
  • [21] Exhaled and sputum nitric oxide in bronchiectasis - Correlation with clinical parameters
    Tsang, KW
    Leung, R
    Fung, PCW
    Chan, SL
    Tipoe, GL
    Ooi, GC
    Lam, WK
    CHEST, 2002, 121 (01) : 88 - 94
  • [22] The correlation between exhaled nitric oxide and sputum eosinophil counts in patients with airways disease
    Haldar, P.
    Shaw, D.
    Siva, R.
    Berry, M.
    Brightling, C.
    Green, R.
    Wardlaw, A.
    Pavord, I.
    THORAX, 2007, 62 : A128 - A129
  • [23] Annual Fractional Exhaled Nitric Oxide Measurements and Exacerbations in Severe Asthma
    Abe, Yuki
    Suzuki, Masaru
    Kimura, Hirokazu
    Shimizu, Kaoruko
    Makita, Hironi
    Nishimura, Masaharu
    Konno, Satoshi
    JOURNAL OF ASTHMA AND ALLERGY, 2020, 13 : 731 - 741
  • [24] Annual Fractional Exhaled Nitric Oxide Measurements and Exacerbations in Severe Asthma
    Abe, Y.
    Suzuki, M.
    Kimura, H.
    Shimizu, K.
    Makita, H.
    Nishimura, M.
    Konno, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [25] Fractional Exhaled Nitric Oxide is Associated with the Severity of Stable COPD
    Liu, Xiaoqian
    Zhang, Hong
    Wang, Ying
    Lu, Yue
    Gao, Yanli
    Lu, Yong
    Zheng, Chunming
    Yin, Danfeng
    Wang, Shurui
    Huang, Kewu
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2020, 17 (02) : 121 - 127
  • [26] Fractional exhaled nitric oxide for eosinophilic inflammation in stable COPD
    Kashiwagi, Yumiko
    Ogawa, Emiko
    Yukimura, Ruriko
    Higami, Yuichi
    Kinose, Daisuke
    Yamaguchi, Masafumi
    Osawa, Makoto
    Nagao, Taishi
    Nakano, Yasutaka
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [27] Correlation between exhaled nitric oxide, sputum eosinophils, and methacholine responsiveness in patients with mild asthma
    Jatakanon, A
    Lim, S
    Kharitonov, SA
    Chung, KF
    Barnes, PJ
    THORAX, 1998, 53 (02) : 91 - 95
  • [28] Exhaled nitric oxide and COPD
    Taylor, D. R.
    Dummer, J.
    EUROPEAN RESPIRATORY JOURNAL, 2010, 36 (03) : 692 - 692
  • [29] Exhaled Nitric Oxide in COPD
    Bikov, Andras
    Meszaros, Martina
    Lazar, Zsofia
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2019, 15 (02) : 71 - 78
  • [30] Eosinophilia and fractional exhaled nitric oxide levels in chronic obstructive lung disease
    Annangi, Srinadh
    Nutalapati, Snigdha
    Sturgill, Jamie
    Flenaugh, Eric
    Foreman, Marilyn
    THORAX, 2022, 77 (04) : 351 - 356