Use of the Humeral Head as a Reference Point to Prevent Axillary Nerve Damage during Proximal Fixation of Humeral Fractures: An Anatomical and Radiographic Study

被引:3
|
作者
Theeuwes, H. P. [1 ,2 ]
Potters, J. W. [2 ,3 ]
Bessems, J. H. J. M. [2 ,3 ]
Kerver, A. J. [2 ,4 ]
Kleinrensink, G. J. [2 ]
机构
[1] Elisabeth TweeSteden Hosp, Dept Surg, Tilburg, Netherlands
[2] Erasmus MC, Dept Neurosci, Anat & Res Program, Rotterdam, Netherlands
[3] Med Spectrum Twente, Dept Anesthesiol, Enschede, Netherlands
[4] Franciscus Gasthuis & Vlietland, Dept Surg, Rotterdam, Netherlands
关键词
Axillary nerve damage; Proximal humeral fracture; Quadrilateral space; Radiography; Safe zone; Surgical anatomy; Trauma surgery; SURGICAL LANDMARKS; BRANCH; PLATE;
D O I
10.5005/jp-journals-10080-1460
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Treatment of proximal humeral fractures with plate osteosynthesis or intramedullary nail fixation in humeral shaft fractures with a proximal locking bolt carries the risk of iatrogenic injury of the axillary nerve. The purpose of this anatomical study is to define a more reliable safe zone to prevent iatrogenic axillary nerve injury using the humeral head instead of the acromion as a (radiographic) reference point during operative treatment. Materials and methods: Anatomical dissection and labeling of the axillary nerve and branches was performed on 10 specially embalmed human specimens. Standard AP and straight lateral radiographs were made. The distances were measured indirectly from the cranial tip of the humerus to the axillary nerve on radiographs. Results: The median distance from the cranial tip of the humerus to the axillary nerve was 52 mm. The mean number of axillary nerve branches was 3. The distances from the cranial tip of the humerus to the nerve (branch) varied from 23 to 78 mm. The median distance from the proximal (anterior) branch was 36 mm, to the second branch 47 mm, 54 mm to the third branch and 73 mm to the fourth branch. The axillary nerve moves along with the humerus in cranial and caudal direction when the subacromial space varies. Conclusion: This study shows that the position of the axillary nerve can be better determent using the cranial tip of the humerus as a reference point instead of the acromion. Furthermore, it is unsafe to place the proximal locking bolts in the zone between 24 mm and 78 mm from the cranial tip of the humerus. The greatest chance to cause a lesion of the main branch of the axillary nerve is in the zone between 48 mm and 58 mm caudal from the tip of the humeral head.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [31] Assessment of axillary nerve function and functional outcome after fixation of complex proximal humeral fractures using the extended deltoid-splitting approach
    Khan, Lukman A. K.
    Robinson, C. Michael
    Will, Elizabeth
    Whittaker, Roger
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (02): : 181 - 185
  • [32] Locking plate fixation with and without inferomedial screws for proximal humeral fractures: a biomechanical study
    Burke, Neil G.
    Kennedy, Jim
    Cousins, Grainne
    Fitzpatrick, David
    Mullett, Hannan
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (02): : 190 - 194
  • [33] Minimally Invasive Polyaxial Locking Plate Fixation of Proximal Humeral Fractures: A Prospective Study
    Ruchholtz, Steffen
    Hauk, Carsten
    Lewan, Ulrike
    Franz, Daniel
    Kuehne, Christian
    Zettl, Ralph
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (06): : 1737 - 1744
  • [34] Tipps und Tricks für die Fixation von Humeruskopffrakturen mit einem proximalen HumerusnagelTips and tricks for the fixation of humeral head fractures with a proximal humeral nail
    H.W. Stedtfeld
    Obere Extremität, 2011, 6 (1) : 52 - 60
  • [35] Radiographic parameter(s) influencing functional outcomes following angular stable plate fixation of proximal humeral fractures
    Ahrend, Marc-Daniel
    Kuhle, Luise
    Riedmann, Stephan
    Bahrs, Sonja D.
    Bahrs, Christian
    Ziegler, Patrick
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1845 - 1852
  • [36] Radiographic and clinical results of tension suture fixation using two washers with PHILOS plate for proximal humeral fractures
    Cho, Chul-Hyun
    Kim, Du Han
    Kim, Beom-Soo
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (02): : 464 - 468
  • [37] Radiographic parameter(s) influencing functional outcomes following angular stable plate fixation of proximal humeral fractures
    Marc-Daniel Ahrend
    Luise Kühle
    Stephan Riedmann
    Sonja D. Bahrs
    Christian Bahrs
    Patrick Ziegler
    International Orthopaedics, 2021, 45 : 1845 - 1852
  • [38] Relationship between axillary nerve and percutaneously inserted proximal humeral locking plate: a cadaver study
    Esenyel, Cem Zeki
    Dedeoglu, Semih
    Imren, Yunus
    Kahraman, Sinan
    Cakar, Murat
    Ozturk, Kahraman
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (05) : 553 - 557
  • [39] Use of angle-stable implants for proximal humeral fractures:: Prospective study
    Krivohlavek, M.
    Lukas, R.
    Taller, S.
    Sram, J.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2008, 75 (03) : 212 - 220
  • [40] Does the location of the entry point affect the reduction of proximal humeral fractures? A cadaveric study
    Noda, Mitsuaki
    Saegusa, Yasuhiro
    Maeda, Toshihisa
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 : S35 - S38