Use of the Humeral Head as a Reference Point to Prevent Axillary Nerve Damage during Proximal Fixation of Humeral Fractures: An Anatomical and Radiographic Study

被引:3
|
作者
Theeuwes, H. P. [1 ,2 ]
Potters, J. W. [2 ,3 ]
Bessems, J. H. J. M. [2 ,3 ]
Kerver, A. J. [2 ,4 ]
Kleinrensink, G. J. [2 ]
机构
[1] Elisabeth TweeSteden Hosp, Dept Surg, Tilburg, Netherlands
[2] Erasmus MC, Dept Neurosci, Anat & Res Program, Rotterdam, Netherlands
[3] Med Spectrum Twente, Dept Anesthesiol, Enschede, Netherlands
[4] Franciscus Gasthuis & Vlietland, Dept Surg, Rotterdam, Netherlands
关键词
Axillary nerve damage; Proximal humeral fracture; Quadrilateral space; Radiography; Safe zone; Surgical anatomy; Trauma surgery; SURGICAL LANDMARKS; BRANCH; PLATE;
D O I
10.5005/jp-journals-10080-1460
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Treatment of proximal humeral fractures with plate osteosynthesis or intramedullary nail fixation in humeral shaft fractures with a proximal locking bolt carries the risk of iatrogenic injury of the axillary nerve. The purpose of this anatomical study is to define a more reliable safe zone to prevent iatrogenic axillary nerve injury using the humeral head instead of the acromion as a (radiographic) reference point during operative treatment. Materials and methods: Anatomical dissection and labeling of the axillary nerve and branches was performed on 10 specially embalmed human specimens. Standard AP and straight lateral radiographs were made. The distances were measured indirectly from the cranial tip of the humerus to the axillary nerve on radiographs. Results: The median distance from the cranial tip of the humerus to the axillary nerve was 52 mm. The mean number of axillary nerve branches was 3. The distances from the cranial tip of the humerus to the nerve (branch) varied from 23 to 78 mm. The median distance from the proximal (anterior) branch was 36 mm, to the second branch 47 mm, 54 mm to the third branch and 73 mm to the fourth branch. The axillary nerve moves along with the humerus in cranial and caudal direction when the subacromial space varies. Conclusion: This study shows that the position of the axillary nerve can be better determent using the cranial tip of the humerus as a reference point instead of the acromion. Furthermore, it is unsafe to place the proximal locking bolts in the zone between 24 mm and 78 mm from the cranial tip of the humerus. The greatest chance to cause a lesion of the main branch of the axillary nerve is in the zone between 48 mm and 58 mm caudal from the tip of the humeral head.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [21] Percutaneous fixation of displaced proximal humeral fractures:: Indications based on the correlation between clinical and radiographic results
    Calvo, Emilio
    de Miguel, Ignacio
    de la Cruz, Juan J.
    Lopez-Martin, Nestor
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (06) : 774 - 781
  • [22] Comparison of Radiographic and Clinical Results between MIPO Internal Fixation and Auxiliary Tension Suture Fixation for Proximal Humeral Fractures
    Yu, X.
    Zhang, H.
    Xu, R. J.
    Huang, A. Q.
    Yu, Z. H.
    Miao, Y.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 82 : 109 - 114
  • [23] Relationship of the axillary nerve to the proximal screws of a flexible humeral nail system: An anatomic study
    Albritton, MJ
    Barnes, CJ
    Basamania, CJ
    Karas, SG
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (06) : 411 - 414
  • [24] Nerve Monitoring During Proximal Humeral Fracture Fixation: What Have We Learned?
    Warrender, William J.
    Oppenheimer, Stephen
    Abboud, Joseph A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (09) : 2631 - 2637
  • [25] Clinical and Radiographic Outcomes After Surgical Treatment of Proximal Humeral Fractures with Head-Split Component
    Peters, Paulina-Maria
    Plachel, Fabian
    Danzinger, Victor
    Novi, Michele
    Maerdian, Sven
    Scheibel, Markus
    Moroder, Philipp
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (01): : 68 - 75
  • [26] A Biomechanical Study of Tuberosity-Based Locked Plate Fixation Compared with Standard Proximal Humeral Locking Plate Fixation for 3-Part Proximal Humeral Fractures
    Walker, Robert
    Castaneda, Paulo
    Putnam, Jill G.
    Schemitsch, Emil H.
    McKee, Michael D.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (07) : E233 - E238
  • [27] Locking Plates versus Locking Intramedullary Nails Fixation of Proximal Humeral Fractures Involving the Humeral Shaft: A Retrospective Cohort Study
    Song, Hui
    He, Tao
    Guo, Hui-Min Y.
    Li, Zhan-Yu
    Wei, Min
    Zhang, Chao
    Dong, Yu-Qi
    MEDICAL SCIENCE MONITOR, 2020, 26 : e922598
  • [28] The calcar screw in angular stable plate fixation of proximal humeral fractures - a case study
    Georg Osterhoff
    Christian Ossendorf
    Guido A Wanner
    Hans-Peter Simmen
    Clément M Werner
    Journal of Orthopaedic Surgery and Research, 6
  • [29] Semitubular blade plate fixation in proximal humeral fractures: A biomechanical study in a cadaveric model
    Instrum, K
    Fennell, C
    Shrive, N
    Damson, E
    Sonnabend, D
    Hollinshead, R
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (05) : 462 - 466
  • [30] The calcar screw in angular stable plate fixation of proximal humeral fractures - a case study
    Osterhoff, Georg
    Ossendorf, Christian
    Wanner, Guido A.
    Simmen, Hans-Peter
    Werner, Clement M.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2011, 6