Analysis of prostate intensity- and volumetric-modulated arc radiation therapy planning quality with PlanIQTM

被引:14
|
作者
Sasaki, Motoharu [1 ]
Nakaguuchi, Yuji [2 ]
Kamomae, Takeshi [3 ]
Tsuzuki, Akira [4 ]
Kobuchi, Satoshi [5 ]
Kuwahara, Kenmei [5 ]
Ueda, Shoji [6 ]
Endo, Yuto [6 ]
Ikushima, Hitoshi [1 ]
机构
[1] Tokushima Univ, Grad Sch, Inst Biomed Sci, Tokushima, Japan
[2] Toyo Medic Co Ltd, Tokyo, Japan
[3] Nagoya Univ, Grad Sch Med, Dept Radiol, Nagoya, Aichi, Japan
[4] Kochi Univ Hosp, Dept Radiol Technol, Kochi, Japan
[5] Tokushima Univ, Grad Sch Hlth Sci, Tokushima, Japan
[6] Tokushima Univ, Sch Hlth Sci, Tokushima, Japan
来源
关键词
Feasibility DVHTM; IMRT; PlanIQ(TM); Prostate cancer; VMAT;
D O I
10.1002/acm2.13233
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to assess the quality of treatment planning using the PlanIQ(TM) software and to investigate whether it is possible to improve the quality of treatment planning using the "Feasibility dose-volume histogram (DVH)(TM)" implemented in the PlanIQ(TM) software. Methods Using the PlanIQ(TM) software, we retrospectively analyzed the learning curve regarding the quality of the treatment plans for 148 patients of prostate intensity-modulated radiation therapy and volumetric-modulated radiation therapy performed at our institution over the past eight years. We also sought to examine the possibility of improving treatment planning quality by re-planning in 47 patients where the quality of the target dose and the dose limits for organs at risk (OARs) were inadequate. The re-planning treatment plans referred to the Feasibility DVHTM implemented in the PlanIQ(TM) software and modified the treatment planning system based on the target dose and OAR constraints. Results Analysis of the learning curve of the treatment plans quality using PlanIQ(TM) software retrospectively showed a trend of improvement in the treatment plan quality from year to year. The improvement in the treatment plans quality was more influenced by dose reduction in the OARs than by target coverage. In all cases where re-planning was performed, the improvement in the treatment plan's quality resulted in a better treatment plan than the one adopted for delivery to patients in the clinical plan. Conclusions The PlanIQ(TM) provided insights into the quality of the treatment plans at our institution and identified problems and areas for improvement in the treatment plans, allowing for the development of appropriate treatment plans for specific patients.
引用
收藏
页码:132 / 142
页数:11
相关论文
共 50 条
  • [41] Comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy in the treatment of cervical esophageal carcinoma
    Yang, Hao
    Feng, Cong
    Cai, Bo-Ning
    Yang, Jun
    Liu, Hai-Xia
    Ma, Lin
    DISEASES OF THE ESOPHAGUS, 2017, 30 (02):
  • [42] An updating approach for knowledge-based planning models to improve plan quality and variability in volumetric-modulated arc therapy for prostate cancer
    Nakamura, Kenji
    Okuhata, Katsuya
    Tamura, Mikoto
    Otsuka, Masakazu
    Kubo, Kazuki
    Ueda, Yoshihiro
    Nakamura, Yasunori
    Nakamatsu, Kiyoshi
    Tanooka, Masao
    Monzen, Hajime
    Nishimura, Yasumasa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 113 - 122
  • [43] Association of volumetric-modulated arc therapy with radiation pneumonitis in thoracic esophageal cancer
    Inoo, Hiroyuki
    Sakanaka, Katsuyuki
    Fujii, Kota
    Ishida, Yuichi
    Mizowaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (04) : 646 - 656
  • [44] Plan quality and delivery time comparisons between volumetric modulated arc therapy and intensity modulated radiation therapy for scalp angiosarcoma: A planning study
    Kai, Yudai
    Toya, Ryo
    Saito, Tetsuo
    Kuraoka, Akiko
    Shimohigashi, Yoshinobu
    Nakaguchi, Yuji
    Maruyama, Masato
    Murakami, Ryuji
    Yamashita, Yasuyuki
    Oya, Natsuo
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2018, 65 (01): : 39 - 47
  • [45] Is Auto-Planning Useful for Volumetric-Modulated Arc Therapy Planning in Rectal Cancer Radiotherapy?
    Li, K.
    Chang, X.
    Wang, J.
    Hu, P.
    Hu, W.
    MEDICAL PHYSICS, 2016, 43 (06) : 3545 - 3545
  • [46] A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans
    Li, Guangjun
    Wu, Kui
    Peng, Guang
    Zhang, Yingjie
    Bai, Sen
    MEDICAL DOSIMETRY, 2014, 39 (04) : 309 - 313
  • [47] FusionArc optimization: A hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy
    Matuszak, Martha M.
    Steers, Jennifer M.
    Long, Troy
    McShan, Daniel L.
    Fraass, Benedick A.
    Romeijn, H. Edwin
    Ten Haken, Randall K.
    MEDICAL PHYSICS, 2013, 40 (07)
  • [48] A dosimetric comparison of volumetric modulated arc therapy with step-and-shoot intensity modulated radiation therapy for prostate cancer
    Mellon, Eric A.
    Javedan, Khosrow
    Strom, Tobin J.
    Moros, Eduardo G.
    Biagioli, Matthew C.
    Fernandez, Daniel C.
    Wasserman, Stu G.
    Wilder, Richard B.
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (01) : 11 - 15
  • [49] Comparison of Three-Dimensional Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy, and Volumetric-Modulated Arc Therapy In Glioblastoma Multiforme Radiation Therapy With EORTC Target Delineation
    Ibis, Kamuran
    Akbas, Ugur
    Koksal, Canan
    Altun, Musa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2018, 33 (02): : 65 - 72
  • [50] Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans
    Maraghechi, Borna
    Davis, Jack
    Badu, Shyam
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 44 - 52