Analysis of prostate intensity- and volumetric-modulated arc radiation therapy planning quality with PlanIQTM

被引:14
|
作者
Sasaki, Motoharu [1 ]
Nakaguuchi, Yuji [2 ]
Kamomae, Takeshi [3 ]
Tsuzuki, Akira [4 ]
Kobuchi, Satoshi [5 ]
Kuwahara, Kenmei [5 ]
Ueda, Shoji [6 ]
Endo, Yuto [6 ]
Ikushima, Hitoshi [1 ]
机构
[1] Tokushima Univ, Grad Sch, Inst Biomed Sci, Tokushima, Japan
[2] Toyo Medic Co Ltd, Tokyo, Japan
[3] Nagoya Univ, Grad Sch Med, Dept Radiol, Nagoya, Aichi, Japan
[4] Kochi Univ Hosp, Dept Radiol Technol, Kochi, Japan
[5] Tokushima Univ, Grad Sch Hlth Sci, Tokushima, Japan
[6] Tokushima Univ, Sch Hlth Sci, Tokushima, Japan
来源
关键词
Feasibility DVHTM; IMRT; PlanIQ(TM); Prostate cancer; VMAT;
D O I
10.1002/acm2.13233
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to assess the quality of treatment planning using the PlanIQ(TM) software and to investigate whether it is possible to improve the quality of treatment planning using the "Feasibility dose-volume histogram (DVH)(TM)" implemented in the PlanIQ(TM) software. Methods Using the PlanIQ(TM) software, we retrospectively analyzed the learning curve regarding the quality of the treatment plans for 148 patients of prostate intensity-modulated radiation therapy and volumetric-modulated radiation therapy performed at our institution over the past eight years. We also sought to examine the possibility of improving treatment planning quality by re-planning in 47 patients where the quality of the target dose and the dose limits for organs at risk (OARs) were inadequate. The re-planning treatment plans referred to the Feasibility DVHTM implemented in the PlanIQ(TM) software and modified the treatment planning system based on the target dose and OAR constraints. Results Analysis of the learning curve of the treatment plans quality using PlanIQ(TM) software retrospectively showed a trend of improvement in the treatment plan quality from year to year. The improvement in the treatment plans quality was more influenced by dose reduction in the OARs than by target coverage. In all cases where re-planning was performed, the improvement in the treatment plan's quality resulted in a better treatment plan than the one adopted for delivery to patients in the clinical plan. Conclusions The PlanIQ(TM) provided insights into the quality of the treatment plans at our institution and identified problems and areas for improvement in the treatment plans, allowing for the development of appropriate treatment plans for specific patients.
引用
收藏
页码:132 / 142
页数:11
相关论文
共 50 条
  • [21] Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy
    Clemente, S.
    Cozzolino, M.
    Oliviero, C.
    Fiorentino, A.
    Chiumento, C.
    Fusco, V.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2014, 16 (02): : 141 - 146
  • [22] Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning
    Motoharu Sasaki
    Masahide Tominaga
    Takeshi Kamomae
    Hitoshi Ikushima
    Motonori Kitaoka
    Ryota Bando
    Kanako Sakuragawa
    Masataka Oita
    Japanese Journal of Radiology, 2017, 35 : 511 - 525
  • [23] Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy
    S. Clemente
    M. Cozzolino
    C. Oliviero
    A. Fiorentino
    C. Chiumento
    V. Fusco
    Clinical and Translational Oncology, 2014, 16 : 141 - 146
  • [24] Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning
    Sasaki, Motoharu
    Tominaga, Masahide
    Kamomae, Takeshi
    Ikushima, Hitoshi
    Kitaoka, Motonori
    Bando, Ryota
    Sakuragawa, Kanako
    Oita, Masataka
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (09) : 511 - 525
  • [25] Stereotactic body radiation therapy planning with duodenal sparing using Volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis
    Kumar, Rachit
    Wild, Aaron T.
    Ziegler, Mark A.
    Hooker, Ted K.
    Dah, Samson D.
    Tran, Phuoc T.
    Kang, Jun
    Smith, Koren
    Zeng, Jing
    Pawlik, Timothy M.
    Tryggestad, Erik
    Ford, Eric
    Herman, Joseph M.
    MEDICAL DOSIMETRY, 2013, 38 (03) : 243 - 250
  • [26] Comparative analysis of volumetric-modulated arc therapy and intensity-modulated radiotherapy for base of tongue cancer
    Nithya, L.
    Raj, N. Arunai Nambi
    Arulraj, Kumar
    Rathinamuthu, Sasikumar
    Pandey, Manish Bhushan
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (02) : 121 - 126
  • [27] Treatment Planning for Volumetric-Modulated Arc Therapy: Model and Heuristic Algorithms
    Song, Jie
    Shi, Zhongshun
    Sun, Bofei
    Shi, Leyuan
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2015, 12 (01) : 116 - 126
  • [28] A class solution for volumetric-modulated arc therapy planning in postprostatectomy radiotherapy
    Forde, Elizabeth
    Bromley, Regina
    Kneebone, Andrew
    Eade, Thomas
    MEDICAL DOSIMETRY, 2014, 39 (03) : 261 - 265
  • [29] Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation-A comparison with traditional techniques
    Studenski, Matthew T.
    Shen, Xinglei
    Yu, Yan
    Xiao, Ying
    Shi, Wenyin
    Biswas, Tithi
    Werner-Wasik, Maria
    Harrison, Amy S.
    MEDICAL DOSIMETRY, 2013, 38 (01) : 48 - 54
  • [30] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Samir, Fady
    Meaz, Talaat M.
    Hussiny, Fathi AEl
    Ahmed, Ahmed A.
    Mahmoud, Amr A.
    Refaat, Tamer
    Gawish, Ahmed
    Abouegylah, Mohamed
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2023, 149 (09) : 6239 - 6246