Initial In Vivo Testing of a Self-Balancing Pulsatile Continuous Flow Total Artificial Heart

被引:0
|
作者
Golding, L. A. R. [1 ]
Fukamachi, K. [1 ]
Horvath, D. J. [1 ]
Massiello, A. L. [1 ]
Fumoto, H. [1 ]
Arakawa, Y. [1 ]
Catanese, J. [1 ]
Chen, J. -F. [1 ]
Mielke, N. [1 ]
Horai, T. [1 ]
机构
[1] Cleveland Clin, Lerner Res Inst, Cleveland, OH 44106 USA
来源
关键词
D O I
10.1016/j.healun.2008.11.901
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
715
引用
收藏
页码:S314 / S315
页数:2
相关论文
共 50 条
  • [41] In vivo evaluation of pressure head and flow rate estimation in a continuous-flow artificial heart
    Tanaka, A
    Yoshizawa, M
    Yamada, T
    Abe, K
    Takeda, H
    Yambe, T
    Nitta, S
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3060 - 3063
  • [42] In vivo evaluation of pressure head and flow rate estimation on a continuous-flow artificial heart
    Tanaka, A
    Aizawa, Y
    Yoshizawa, M
    Olegario, P
    Abe, K
    Takeda, H
    Yambe, T
    Nitta, S
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1573 - 1574
  • [43] Estimation of pressure head and flow rate in a continuous-flow artificial heart -: In vivo evaluation
    Tanaka, A
    Yoshizawa, M
    Aizawa, Y
    Olegario, P
    Abe, K
    Yambe, T
    Nitta, S
    SICE 2002: PROCEEDINGS OF THE 41ST SICE ANNUAL CONFERENCE, VOLS 1-5, 2002, : 527 - 530
  • [44] In vivo test of pressure head and flow rate estimation in a continuous-flow artificial heart
    Tanaka, A
    Yoshizawa, M
    Abe, K
    Takeda, H
    Yambe, T
    Nitta, S
    ARTIFICIAL ORGANS, 2003, 27 (01) : 99 - 103
  • [45] NEW VERSION OF FLOW-TRANSFORMED PULSATILE TOTAL ARTIFICIAL-HEART WITH NO ELECTRICAL SWITCHING VALVE
    ISOYAMA, T
    IMACHI, K
    ABE, Y
    CHINZEI, T
    IMANISHI, K
    MABUCHI, K
    MATSUURA, H
    FUJIMASA, I
    ARTIFICIAL ORGANS, 1995, 19 (07) : 694 - 696
  • [46] Continuous in-line measurement of viscosity using self-balancing electromagnetically spinning technique
    Hosoda, Maiko
    Yamakawa, Yoshikazu
    Sakai, Keiji
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (SK)
  • [47] Mock Circulation Loop to Investigate Hemolysis in a Pulsatile Total Artificial Heart
    Graef, Felix
    Finocchiaro, Thomas
    Laumen, Marco
    Mager, Ilona
    Steinseifer, Ulrich
    ARTIFICIAL ORGANS, 2015, 39 (05) : 416 - 422
  • [48] PULSATILE TOTAL ARTIFICIAL-HEART USING A REVERSIBLE ROTARY PUMP
    FUKUNAGA, S
    MITSUI, N
    HOTEI, H
    NAGATA, H
    WATARI, M
    TAHARA, K
    SUEDA, T
    MATSUURA, Y
    ARTIFICIAL ORGANS, 1995, 19 (07) : 701 - 703
  • [49] The MiniACcor:: Constructive redesign of an implantable total artificial heart, initial laboratory testing and further steps
    Kwant, P. B.
    Finocchiaro, T.
    Foerster, F.
    Reul, H.
    Rau, G.
    Morshuis, M.
    El Banayosi, A.
    Koerfer, R.
    Schmitz-Rode, T.
    Steinseifer, U.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2007, 30 (04): : 345 - 351
  • [50] Mechanical Circulatory Support for Biventricular Heart Failure Using Continuous-Flow Total Artificial Heart
    Karimov, J. H.
    Horvath, D.
    Byram, N.
    Polakowski, A.
    Adams, J.
    Kado, Y.
    Miyamoto, T.
    Sale, S.
    Kuban, B.
    Fukamachi, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S343 - S343