On-Line Dialysate Infusion to Estimate Absolute Blood Volume in Dialysis Patients

被引:29
|
作者
Schneditz, Daniel [1 ]
Schilcher, Gernot [2 ]
Ribitsch, Werner [2 ]
Krisper, Peter [2 ]
Haditsch, Bernd [1 ]
Kron, Joachim [3 ]
机构
[1] Med Univ Graz, Inst Physiol, A-8010 Graz, Austria
[2] Med Univ Graz, Clin Div Nephrol, Dept Internal Med, A-8010 Graz, Austria
[3] KfH Kidney Ctr Berlin Kopenick, KfH Kuratorium Dialyse & Nierentransplantat, Berlin, Germany
关键词
ultra-pure dialysate; indicator dilution; volume kinetics; blood volume; half-life; TOTAL PROTEIN-CONCENTRATION; CARDIOPULMONARY RECIRCULATION; SOUND-SPEED; HEMODIALYSIS; HYPOTENSION; PRESSURE; HEMATOCRIT; DENSITY; FLUID;
D O I
10.1097/MAT.0000000000000086
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It was the aim to measure the distribution volume and the elimination of ultra-pure dialysate in stable hemodialysis patients during on-line hemodiafiltration (HDF). Dialysate was automatically infused as a volume indicator using standard on-line HDF equipment. Indicator concentration was noninvasively measured in the arterial blood-line (using the blood volume monitor, Fresenius Medical Care, Bad Homburg vor der H he, Germany), and its time course was analyzed to obtain the elimination rate and the distribution volume V-t at the time of dilution. Blood volume at treatment start (V-0) was calculated accounting for the degree of intradialytic hemoconcentration. Five patients (two females) were studied during 15 treatments. Two to six measurements using indicator volumes ranging from 60 to 210 ml were done in each treatment. V-0 was 4.59 +/- 1.15 L and larger than the volume of 4.08 +/- 0.48 L estimated from anthropometric relationships. The mean half-life of infused volume was 17.2 +/- 29.7 min. Given predialysis volume expansion V-0 was consistent with blood volume determined from anthropometric measurements. Information on blood volume could substantially improve volume management in hemodialysis patients and fluid therapy in intensive care patients undergoing extracorporeal blood treatment. The system has the potential for complete automation using proper control inputs for BVM and HDF modules of the dialysis machine.
引用
收藏
页码:436 / 442
页数:7
相关论文
共 50 条
  • [21] On-line dynamic measurement of blood viscosity, hematocrit and change of blood volume
    尹志勇
    周继红
    蔡绍皙
    王正国
    Chinese Journal of Traumatology, 2000, (02)
  • [22] Effect of increased dialysate volume on peritoneal surface area among peritoneal dialysis patients
    Chagnac, A
    Herskovitz, P
    Ori, Y
    Weinstein, T
    Hirsh, J
    Katz, M
    Gafter, U
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (10): : 2554 - 2559
  • [23] Dialysis dose (Kt/V) and clearance variation sensitivity using measurement of ultraviolet-absorbance (on-line), blood urea, dialysate urea and ionic dialysance
    Uhlin, Fredrik
    Fridolin, Ivo
    Magnusson, Martin
    Lindberg, Lars-Goran
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (08) : 2225 - 2231
  • [24] Nutrition estimation of dialysis patients by on-line monitoring and kinetic modelling
    Fridolin, Ivo
    Lauri, Kai
    Jerotskaja, Jana
    Luman, Merike
    Estonian Journal of Engineering, 2008, 14 (02): : 177 - 188
  • [25] Measurement of central blood volume by slow infusion of ultra-pure dialysate during hemodialysis.
    Wimmer, J
    Haditsch, B
    Holzer, H
    Schneditz, D
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 851A - 851A
  • [26] ABSOLUTE BLOOD VOLUME AND VASCULAR REFILLING IN HAEMODIALYSIS PATIENTS
    Alvarez Nadal, Marta
    Viera Ramirez, Elizabeth
    Martin, Irene
    Ruiz-Roso Lopez, Gloria
    Delgado Yague, Maria
    Fernandez Lucas, Milagros
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 1840 - 1840
  • [27] DETERMINATION OF ALUMINUM LEVELS IN SERUM, BLOOD AND DIALYSATE OF RENAL PATIENTS ON DIALYSIS BY ZEEMAN AAS
    TYTKO, SA
    KERKAY, J
    PEARSON, KH
    CLINICAL CHEMISTRY, 1984, 30 (06) : 974 - 974
  • [28] Mathematical Modeling of Different Molecule Removal on On-Line Haemodiafiltration: Influence of Dialysis Duration and Infusion Flow
    Maduell, Francisco
    Sanchez, Juan
    Net, Marta
    Gomez, Miquel
    Gonzalez, Jose M.
    Arias-Guillen, Marta
    Rodriguez, Nestor
    Rico, Nayra
    Campistol, Josep M.
    BLOOD PURIFICATION, 2015, 39 (04) : 288 - 296
  • [29] Ionic dialysance as a method for the on-line monitoring of delivered dialysis without blood sampling
    Manzoni, C
    DiFilippo, S
    Corti, M
    Locatelli, F
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1996, 11 (10) : 2023 - 2030
  • [30] CLINICAL BENEFITS OF ON-LINE HEMODIAFILTRATION FOR THE IMPROVEMENT OF THE QUALITY OF LIFE OF DIALYSIS PATIENTS
    Sakurai, Kenji
    Saito, Takeshi
    Yamauchi, Fumi
    Hosoya, Hiromi
    Suzuki, Ayumi
    Kurihara, Yoshitaka
    Kurosawa, Kaori
    Tanibayashi, Yomi
    Yoshida, Kazunari
    Kokubo, Kenichi
    Ishii, Daisuke
    Hydo, Toru
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34