A study on operational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry

被引:164
|
作者
Hocevar, SB
Ogorevc, B
Wang, J
Pihlar, B
机构
[1] Natl Inst Chem, Analyt Chem Lab, SI-1000 Ljubljana, Slovenia
[2] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[3] Univ Ljubljana, Fac Chem & Chem Technol, Dept Analyt Chem, Ljubljana, Slovenia
关键词
bismuth; modified electrodes; anodic stripping voltammetry; heavy metals; trace analysis;
D O I
10.1002/elan.200290014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study is presented on the characterization, evaluation and optimization of several key operational parameters for a reliable and effective use of a bismuth film electrode (BiFE) as an advanced replacement of the mercury film electrode in anodic stripping voltammetric measurements of trace heavy metals. Applying in situ preparation of the BiFE and employing lead(II) and cadmium(II) as model analyte ions, key parameters including bismuth precursor salt and substrate surface (platinum, gold, glassy carbon, carbon paste, carbon fiber) for bismuth plating, concentration as well as cationic and anionic composition of the measurement solution, solution pH and temperature, potential interferents, and stripping modes were carefully examined for their effects in the preconcentration and stripping steps. Parameters such as substrate surface (except platinum), precursor salt, solution matrix and temperature showed no or little impact on the BiFE performance in stripping analysis. On the other hand, the BiFE performance was found to be dependent on the solution pH (with maximum efficiency in the range of 4 to 5), on the stripping mode (with square-wave voltammetry as the best choice) and to a certain degree on the presence of surface active substances. The results revealed that the non-toxic solid-state BiFE is applicable under a wide variety of conditions which proves it highly suitable for practical work in environmental trace heavy metal analysis.
引用
收藏
页码:1707 / 1712
页数:6
相关论文
共 50 条
  • [41] Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode
    Giacomino, Agnese
    Abollino, Omella
    Malandrino, Mery
    Mentasti, Edoardo
    TALANTA, 2008, 75 (01) : 266 - 273
  • [42] Determination of subnanomolar concentrations of cobalt by adsorptive stripping voltammetry at a bismuth film electrode
    Mieczyslaw Korolczuk
    Aleksandra Moroziewicz
    Malgorzata Grabarczyk
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1678 - 1682
  • [43] Determination of subnanomolar concentrations of cobalt by adsorptive stripping voltammetry at a bismuth film electrode
    Korolczuk, M
    Moroziewicz, A
    Grabarczyk, M
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (07) : 1678 - 1682
  • [44] A PYROLYTIC CARBON-FILM ELECTRODE FOR VOLTAMMETRY .3. APPLICATION TO ANODIC-STRIPPING VOLTAMMETRY
    GUSTAVSSON, I
    LUNDSTROM, K
    TALANTA, 1983, 30 (12) : 959 - 962
  • [45] Determination of Trace Lead and Cadmium in Water Samples by Anodic Stripping Voltammetry with a NafionIonic Liquid-Coated Bismuth Film Electrode
    Yang, Die
    Wang, Liang
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravi
    ELECTROANALYSIS, 2014, 26 (03) : 639 - 647
  • [46] Scope of detection and determination of gallium(III) in industrial ground water by square wave anodic stripping voltammetry on bismuth film electrode
    Kamat, J. V.
    Guin, Saurav K.
    Pillai, Jisha S.
    Aggarwal, Suresh K.
    TALANTA, 2011, 86 : 256 - 265
  • [47] Determination of cadmium with a sequential injection lab-on-valve by anodic stripping voltammetry using a nafion coated bismuth film electrode
    Wang, Yang
    Liu, Zaiqing
    Yao, Guojun
    Zhu, Peihua
    Hu, Xiaoya
    Xu, Qin
    Yang, Chun
    TALANTA, 2010, 80 (05) : 1959 - 1963
  • [48] Determination of lead and cadmium by anodic stripping voltammetry at bismuth film electrodes following double deposition and stripping steps
    Rutyna, Iwona
    Korolczuk, Mieczyslaw
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 136 - 141
  • [49] Determination of Lead and Cadmium in Sea- and Freshwater by Anodic Stripping Voltammetry with a Vibrating Bismuth Electrode
    Bi, Zhaoshun
    Chapman, Conrad S.
    Salauen, Pascal
    van den Berg, Constant M. G.
    ELECTROANALYSIS, 2010, 22 (24) : 2897 - 2907
  • [50] Bismuth-Coated Iridium Microwire Electrode for the Determination of Trace Metals by Anodic Stripping Voltammetry
    Kyrisoglou, Christos
    Economou, Anastasios
    Efstathiou, Constantinos E.
    ELECTROANALYSIS, 2012, 24 (09) : 1825 - 1832