Influence of an electret on the sensitivity of CR-39 nuclear track detector in diffusion chamber

被引:2
|
作者
Nikezic, D. [1 ]
Krstic, D. [1 ]
机构
[1] Univ Kragujevac, Fac Sci, Kragujevac, Serbia
关键词
Diffusion chamber; nuclear track detector; electret; sensitivity; RADON; RN-222;
D O I
10.1007/s12648-009-0039-6
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Cylindrical diffusion chamber for radon measurement equipped with nuclear track detector(CR-39) and electret is considered in this work. Electret is electrostatic analogous of permanent magnet which preserves constant and strong electric field for long time period. Electrets were used to attract radon progeny formed in a cup where CR-39 was placed for radon measurements. In this way the sensitivity of detector could be increased by bringing progeny just in front of detector in more convenient measuring geometry. Influence of distance between electret and detector on sensitivity of such equipment has been investigated theoretically. Different geometrical setups of detector and electret were tested in order to optimize this kind of device. Some results are presented in this report.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 50 条
  • [21] Distribution of alpha particle tracks on CR-39 detector in radon diffusion chamber
    Stajic, J. M.
    Markovic, V. M.
    Milenkovic, B.
    Stevanovic, N.
    Nikezic, D.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 181
  • [22] Color changes in CR-39 nuclear track detector by gamma and laser irradiation
    Nouh, SA
    Said, AF
    Atta, MR
    El-Melleegy, WM
    El-Meniawy, S
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2006, 161 (07): : 411 - 419
  • [23] Calibration of solid state nuclear track detector CR-39 with monoenergetic protons
    Duan Xiao-Jiao
    Tan Zhi-Xin
    Lan Xiao-Fei
    Huang Yong-Sheng
    Guo Shi-Lun
    Yang Da-Wei
    Tang Xiu-Zhang
    Wang Nai-Yan
    ACTA PHYSICA SINICA, 2010, 59 (05) : 3147 - 3153
  • [24] A NEW NUCLEAR TRACK FILTER OF CR-39
    BERNDT, M
    SIEGMON, G
    BEAUJEAN, R
    ENGE, W
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 589 - 592
  • [25] Gamma dosimetry with CR-39 etch track detector
    Matiullah
    Dogar, Ashiq Hussain
    Ahmad, Nasir
    Amin, Masood
    Kudo, Katsuhisa
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (6 A): : 3761 - 3762
  • [26] RESPONSE FUNCTION OF THE PLASTIC TRACK DETECTOR CR-39
    LUCK, HB
    RADIATION EFFECTS LETTERS, 1982, 67 (05): : 141 - 146
  • [27] Gamma dosimetry with CR-39 etch track detector
    Matiullah
    Dogar, AH
    Ahmad, N
    Amin, M
    Kudo, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 (6A): : 3761 - 3762
  • [28] CAN ELECTRIC-FIELD INFLUENCE THE SENSITIVITY OF CR-39 DETECTOR
    MATIULLAH
    TAKEDA, N
    KUDO, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1995, 34 (03): : 1709 - 1710
  • [29] A study of the CR-39 track detector sensitivity to heavy charged particles of space radiation
    Kushin, V. V.
    Inozemtsev, K. O.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2015, 58 (06) : 794 - 798
  • [30] A study of the CR-39 track detector sensitivity to heavy charged particles of space radiation
    V. V. Kushin
    K. O. Inozemtsev
    Instruments and Experimental Techniques, 2015, 58 : 794 - 798