Glenoid suture anchor fixation strength: Effect of insertion angle

被引:27
|
作者
Ilahi, OA [1 ]
Al-Fahl, T [1 ]
Bahrani, H [1 ]
Luo, ZP [1 ]
机构
[1] Baylor Coll Med, Dept Orthoped Surg, Houston, TX 77030 USA
关键词
fixation; SLAP; Bankart; labrum; suture anchor;
D O I
10.1016/j.arthro.2004.04.063
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine the effect of varying insertion angles on the fixation strength of screw-in devices placed in the glenoid rim. Type of Study: Cadaveric biomechanical analysis. Methods: Eighteen cadaveric glenoids had 3.0-mm cannulated screws inserted for a depth of 10 mm in all 4 quadrants: anterior superior (AS), anterior inferior (AT), posterior superior (PS), posterior inferior (PI). Screws were inserted along the orthogonal to the glenoid rim at the point of insertion or at angles that deviated from this vector by 20degrees and 40degrees. Load to failure was performed at 10 mm/s along the orthogonal to the point of insertion. Results: For screws inserted orthogonal to the glenoid rim, the average load to failure was highest for the PS quadrant (733 +/- 369 N) and lowest for the AT quadrant (272 69 N). The AS and PI quadrants showed intermediate values (549 +/- 334 N and 484 +/- 141 N, respectively). Deviation from orthogonal correlated with decreased fixation strength. This decrease was statistically significant in the AS and PI quadrants, with deviation of 40degrees, and in the AT quadrant, with deviation of 20degrees, as well as 40degrees. Conclusions: Insertion angles for screw-in fixation devices should be orthogonal to the glenoid rim at the point of insertion to maximize strength. Deviation of 40degrees from orthogonal compromises fixation in most quadrants and deviation as little as 20degrees can compromise fixation in the AT quadrant. Clinical Relevance: To maximize strength of labral reattachment to the bony glenoid, screw-in type fixation devices should be inserted as orthogonal to the glenoid rim as possible. This is especially true for Bankart repairs, because device pullout occurs at significantly lower loads in the anteroinferior quadrant compared with the other 3 quadrants. Deviating as little as 20degrees further decreases fixation strength significantly.
引用
收藏
页码:609 / 613
页数:5
相关论文
共 50 条
  • [21] Analysis of glenoid inter-anchor distance with an all-suture anchor system
    Kramer, Jonathan D.
    Robinson, Sean
    Purviance, Connor
    Montgomery, William, III
    JOURNAL OF ORTHOPAEDICS, 2018, 15 (01) : 102 - 106
  • [22] Perianchor cyst formation in all-suture anchor after rotator cuff repair: an evaluation of anchor insertion angle
    Kim, Myung Seo
    Rhee, Sung Min
    Cho, Nam Su
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (09) : 1831 - 1839
  • [23] Pullout Strength of All-Suture Anchors: Effect of the Insertion and Traction Angle-A Biomechanical Study
    Oh, Joo Han
    Jeong, Hyeon Jang
    Yang, Seok Hoon
    Rhee, Sung Min
    Itami, Yasuo
    McGarry, Michelle H.
    Lee, Thay Q.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (10): : 2784 - 2795
  • [24] Bone cement improves suture anchor fixation
    Giori, Nicholas J.
    Sohn, David H.
    Mirza, Faisal M.
    Lindsey, Derek P.
    Lee, Arthur T.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) : 236 - 241
  • [25] Arthroscopic Iliac Bone Block Augmentation for Glenoid Reconstruction: Transglenoid Fixation Technique Using an All-Suture Anchor
    Jeong, Jeung Yeol
    Yoo, Yon-Sik
    Kim, Taesoung
    ARTHROSCOPY TECHNIQUES, 2020, 9 (03): : E351 - E356
  • [26] Suture anchor fixation of comminuted inferior pole patella fracture-novel technique: suture bridge anchor fixation technique
    Kim, Kwang-Sub
    Suh, Dong-Whan
    Park, Sang-Eun
    Ji, Jong-Hun
    Han, Young-Hoon
    Kim, Jae-Hoon
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (11) : 1889 - 1897
  • [27] Suture anchor fixation of comminuted inferior pole patella fracture-novel technique: suture bridge anchor fixation technique
    Kwang-Sub Kim
    Dong-Whan Suh
    Sang-Eun Park
    Jong-Hun Ji
    Young-Hoon Han
    Jae-Hoon Kim
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1889 - 1897
  • [28] Variations in glenoid rim anatomy: Implications regarding anchor insertion
    Lehtinen, JT
    Tingart, MJ
    Apreleva, M
    Ticker, JB
    Warner, JJP
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (02): : 175 - 178
  • [29] The Neviaser portal for superior glenoid anchor insertion: an anatomic study
    Haughton, Benjamin Alexander
    Serrano-Pedraza, Ignacio
    Boada, Eduardo
    Candal-Couto, Jaime Jose
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (03) : 301 - 303
  • [30] Glenoid Rim Fracture in Contact Athletes With Absorbable Suture Anchor Reconstruction
    Banerjee, Sughran
    Weiser, Lori
    Connell, David
    Wallace, Andrew L.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (05): : 560 - 562