Glenoid suture anchor fixation strength: Effect of insertion angle

被引:27
|
作者
Ilahi, OA [1 ]
Al-Fahl, T [1 ]
Bahrani, H [1 ]
Luo, ZP [1 ]
机构
[1] Baylor Coll Med, Dept Orthoped Surg, Houston, TX 77030 USA
关键词
fixation; SLAP; Bankart; labrum; suture anchor;
D O I
10.1016/j.arthro.2004.04.063
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine the effect of varying insertion angles on the fixation strength of screw-in devices placed in the glenoid rim. Type of Study: Cadaveric biomechanical analysis. Methods: Eighteen cadaveric glenoids had 3.0-mm cannulated screws inserted for a depth of 10 mm in all 4 quadrants: anterior superior (AS), anterior inferior (AT), posterior superior (PS), posterior inferior (PI). Screws were inserted along the orthogonal to the glenoid rim at the point of insertion or at angles that deviated from this vector by 20degrees and 40degrees. Load to failure was performed at 10 mm/s along the orthogonal to the point of insertion. Results: For screws inserted orthogonal to the glenoid rim, the average load to failure was highest for the PS quadrant (733 +/- 369 N) and lowest for the AT quadrant (272 69 N). The AS and PI quadrants showed intermediate values (549 +/- 334 N and 484 +/- 141 N, respectively). Deviation from orthogonal correlated with decreased fixation strength. This decrease was statistically significant in the AS and PI quadrants, with deviation of 40degrees, and in the AT quadrant, with deviation of 20degrees, as well as 40degrees. Conclusions: Insertion angles for screw-in fixation devices should be orthogonal to the glenoid rim at the point of insertion to maximize strength. Deviation of 40degrees from orthogonal compromises fixation in most quadrants and deviation as little as 20degrees can compromise fixation in the AT quadrant. Clinical Relevance: To maximize strength of labral reattachment to the bony glenoid, screw-in type fixation devices should be inserted as orthogonal to the glenoid rim as possible. This is especially true for Bankart repairs, because device pullout occurs at significantly lower loads in the anteroinferior quadrant compared with the other 3 quadrants. Deviating as little as 20degrees further decreases fixation strength significantly.
引用
收藏
页码:609 / 613
页数:5
相关论文
共 50 条
  • [1] Options for glenoid labral suture anchor fixation
    Rudzki, JR
    Purcell, DB
    Wright, RW
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2004, 12 (04) : 225 - 231
  • [2] Suture Anchor Insertion Angle and the Deadman Theory
    Burkhart, Stephen S.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (12): : 1365 - 1365
  • [3] What Is the Optimum Insertion Angle of a Suture Anchor?
    Lubowitz, James H.
    Provencher, Matthew T.
    Rossi, Michael J.
    Brand, Jefferson C.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (08): : 893 - 894
  • [4] The Effect of the Angle of Suture Anchor Insertion on Fixation Failure at the Tendon-Suture Interface After Rotator Cuff Repair: Deadman's Angle Revisited
    Strauss, Eric
    Frank, Darren
    Kubiak, Erik
    Kummer, Frederick
    Rokito, Andrew
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (06): : 597 - 602
  • [5] Does anchor insertion angle or placement of the suture anchor affect glenoid rim fracture occurrence after arthroscopic Bankart repair?
    Park, Jin-Young
    Lee, Jae-Hyung
    Oh, Kyung-Soo
    Chung, Seok-Won
    Park, HyunJun
    Park, Ju Yong
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (04) : E124 - E129
  • [6] Suture strength and angle of load application in a suture anchor eyelet
    Deakin, M
    Stubbs, D
    Bruce, W
    Goldberg, J
    Gillies, RM
    Walsh, WR
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (12): : 1447 - 1451
  • [7] Editorial Commentary: Shoulder Glenoid Suture Anchor Insertion Depth: The Tip of an Iceberg
    Lubowitz, James H.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (05): : 1391 - 1392
  • [8] The mechanical effects of suture anchor insertion angle for rotator cuff repair
    Liporace, FA
    Penny, K
    Bono, CM
    Feldman, AJ
    Caruso, SA
    Grossman, MG
    Weiner, B
    Haher, TR
    ORTHOPEDICS, 2002, 25 (04) : 399 - 402
  • [9] Safe Angle for Suture Anchor Insertion During Acetabular Labral Repair
    Hernandez, Jaime D.
    McGrath, Brian E.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (12): : 1390 - 1394
  • [10] Suture anchor fixation strength in the Latarjet procedure: a biomechanical study in cadavers
    Behzad Saleky
    Onur Hapa
    Yagmur Isin
    Mustafa Güvençer
    Hasan Havıtçıoğlu
    Bora Uzun
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 1667 - 1672