Optimization of the non-contact fiber delivery systems for clinical laser applications

被引:0
|
作者
Denisov, NA [1 ]
Griffin, SE [1 ]
机构
[1] Natl Tech Univ Ukraine, Kyiv Polytech Inst, UA-252056 Kiev, Ukraine
关键词
fiber delivery system; optimization; non-contact fiber probe; steady beam distance; steady beam ratio;
D O I
10.1117/12.432018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of the study was to design, to investigate and to optimize non-contact fiber delivery system for different clinical applications. This system eliminate the main disadvantages both applied contact and non-contact probes, namely surface contamination with further probe's thermal deterioration and large beam divergence, respectively. The main part of the proposed non-contact fiber delivery system is probe made in fused silica or synthetic sapphire which produces quasi-collimated beam with specific outside diameter and power distribution along this beam. These probes were designed for different laser clinical applications, especially for interstitial thermotherapy and photodynamic therapy. Five different types of them were manufactured by InnovaQuartz, Inc. (Phoenix, AZ, USA) and Tochpribor (Kharkiv, Ukraine). To provide comparative analysis and optimization of the optical properties of the novel fiber delivery systems with commercially available ones "steady beam distance"; "steady beam ratio" and "power density efficiency" coefficients are proposed. The improved versions of the commercial urologic devices "transurethral optical laser knife" (Mayo Clinic), TULIP (Intrasonics), UroLase (Bard), SideFire (Myriadlase), ADD (Laserscope), UltraLine (Heraeus Lasersonics), ProLase II (Cytocare) are examined. The received results could provide a tool useful to designers of non-contact fiber delivery systems intended for different clinical applications with cw and pulse lasers..
引用
收藏
页码:148 / 158
页数:11
相关论文
共 50 条
  • [41] Optimization Study of Non-Contact Color Measurement Parameters
    Wan Xiao-xia
    Fu Ma
    Huang Xin-guo
    Xie Wei
    Li Jun-feng
    Liu Qiang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (09) : 2889 - 2893
  • [42] Manufacturing of optical elements by non-contact laser processing
    Schwarz, Simon
    Rung, Stefan
    Esen, Cemal
    Hellmann, Ralf
    SEVENTH EUROPEAN SEMINAR ON PRECISION OPTICS MANUFACTURING, 2020, 11478
  • [43] New laser vibrometer for non-contact vibration measurement
    不详
    ZKG INTERNATIONAL, 2014, 67 (1-2): : 20 - 20
  • [44] Non-contact in vivo scanning laser microscopy of blebitis
    Sbeity, Z.
    Radcliffe, N.
    Palmiero, P-M
    Tello, C.
    Liebmann, J.
    Ritch, R.
    EYE, 2009, 23 (07) : 1615 - 1616
  • [45] A multifunctional helical fiber operated in non-contact/contact dual-mode sensing aiming for HMI/VR applications
    Liang, Qianqian
    Zhang, Dong
    He, Tianyiyi
    Zhang, Zixuan
    Wu, Yuchen
    Zhang, Guanglin
    Xie, Ruimin
    Chen, Shiyan
    Wang, Huaping
    Lee, Chengkuo
    NANO ENERGY, 2023, 117
  • [46] Non-contact laser speckle anemometry of microcirculatory bloodstream
    Golovan, O. A.
    Velichko, E. N.
    Baranov, M. A.
    Aksenov, E. T.
    2018 INTERNATIONAL CONFERENCE LASER OPTICS (ICLO 2018), 2018, : 523 - 523
  • [47] Non-contact damage monitoring by laser AE technique
    Enoki, M
    Nishinoiri, S
    Third International Conference on Experimental Mechanics and Third Conference of the Asian-Committee-on-Experimental-Mechanics, Pts 1and 2, 2005, 5852 : 214 - 219
  • [48] Non-contact Photoacoustic Tomography with a Laser Doppler Vibrometer
    Xu, Guan
    Wang, Cheng
    Feng, Ting
    Oliver, David E.
    Wang, Xueding
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [49] Non-Contact Interaction of Ultrasonic Wave on Laser Beam
    Muc, S.
    Gudra, T.
    Beres-Pawlik, E.
    ACTA PHYSICA POLONICA A, 2011, 120 (04) : 702 - 704
  • [50] Laser scanning system upgraded with non-contact probe
    不详
    R&D MAGAZINE, 1999, 41 (10): : 4UK - 4UK