Optimization of the non-contact fiber delivery systems for clinical laser applications

被引:0
|
作者
Denisov, NA [1 ]
Griffin, SE [1 ]
机构
[1] Natl Tech Univ Ukraine, Kyiv Polytech Inst, UA-252056 Kiev, Ukraine
关键词
fiber delivery system; optimization; non-contact fiber probe; steady beam distance; steady beam ratio;
D O I
10.1117/12.432018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of the study was to design, to investigate and to optimize non-contact fiber delivery system for different clinical applications. This system eliminate the main disadvantages both applied contact and non-contact probes, namely surface contamination with further probe's thermal deterioration and large beam divergence, respectively. The main part of the proposed non-contact fiber delivery system is probe made in fused silica or synthetic sapphire which produces quasi-collimated beam with specific outside diameter and power distribution along this beam. These probes were designed for different laser clinical applications, especially for interstitial thermotherapy and photodynamic therapy. Five different types of them were manufactured by InnovaQuartz, Inc. (Phoenix, AZ, USA) and Tochpribor (Kharkiv, Ukraine). To provide comparative analysis and optimization of the optical properties of the novel fiber delivery systems with commercially available ones "steady beam distance"; "steady beam ratio" and "power density efficiency" coefficients are proposed. The improved versions of the commercial urologic devices "transurethral optical laser knife" (Mayo Clinic), TULIP (Intrasonics), UroLase (Bard), SideFire (Myriadlase), ADD (Laserscope), UltraLine (Heraeus Lasersonics), ProLase II (Cytocare) are examined. The received results could provide a tool useful to designers of non-contact fiber delivery systems intended for different clinical applications with cw and pulse lasers..
引用
收藏
页码:148 / 158
页数:11
相关论文
共 50 条
  • [31] A non-contact fiber Bragg grating vibration sensor
    Li, Tianliang
    Tan, Yuegang
    Wei, Li
    Zhou, Zude
    Zheng, Kai
    Guo, Yongxing
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (01):
  • [32] CLINICAL TONOMETRIC MEASUREMENTS WITH NON-CONTACT TONOMETER
    AUGSBURG.A
    POLASKY, M
    WALBY, M
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1973, 50 (09): : 743 - 743
  • [33] Clinical evaluation of non-contact infrared thermometers
    Sullivan, Stacey J. L.
    Rinaldi, Jean E.
    Hariharan, Prasanna
    Casamento, Jon P.
    Baek, Seungchul
    Seay, Nathanael
    Vesnovsky, Oleg
    Topoleski, L. D. Timmie
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [34] Non-contact defect imaging of carbon fiber composites using laser excited acoustic shearography
    Tham, Zi Wen
    Sampath, Santhakumar
    Chen, Yi Fan
    Mutiargo, Bisma
    Zhang, Lei
    COMPOSITES SCIENCE AND TECHNOLOGY, 2024, 257
  • [35] CLINICAL TONOMETRIC MEASUREMENTS WITH NON-CONTACT TONOMETER
    AUGSBURGER, A
    POLASKY, M
    WALBY, M
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1974, 51 (04): : 282 - 285
  • [36] Clinical evaluation of non-contact infrared thermometers
    Stacey J. L. Sullivan
    Jean E. Rinaldi
    Prasanna Hariharan
    Jon P. Casamento
    Seungchul Baek
    Nathanael Seay
    Oleg Vesnovsky
    L. D. Timmie Topoleski
    Scientific Reports, 11
  • [37] Mechanical Behavior of Silk Fabric with Different Fiber Diameters Using a Non-contact Laser sensor
    Nakajima, Kenichi
    Miura, Mikihiko
    JARQ-JAPAN AGRICULTURAL RESEARCH QUARTERLY, 2013, 47 (02): : 175 - 183
  • [38] Continuous control systems for non-contact ECG
    Kodkin, Vladimir L.
    Yakovleva, Galina V.
    Smirnov, Alexey S.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES X, 2017, 10056
  • [39] NON-CONTACT EUTECTIC FUSION IN BINARY SYSTEMS
    PETRUCCI, RH
    MELNYK, A
    MULLER, O
    JOURNAL OF CHEMICAL EDUCATION, 1965, 42 (07) : 362 - &
  • [40] Non-contact laser/EMAT measurement systems for ultrasound B-scan imaging
    Dewhurst, RJ
    Murray, PR
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 21A & B, 2002, 615 : 348 - 355