Responses of the endolymphatic sac to perilymphatic injections and withdrawals: evidence for the presence of a one-way valve

被引:45
|
作者
Salt, AN
Rask-Andersen, H
机构
[1] Washington Univ, Sch Med, Dept Otolaryngol, St Louis, MO 63110 USA
[2] Univ Uppsala Hosp, Akad Sjukhuset, Dept Otolaryngol, S-75185 Uppsala, Sweden
关键词
endolymphatic hydrops; endolymphatic sinus; saccule; Meniere's disease;
D O I
10.1016/j.heares.2003.12.018
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Although the endolymphatic sac (ES) is thought to be a primary site for endolymph volume regulation, we have limited knowledge of how it responds to volume and pressure changes. In a prior publication, we demonstrated changes of K+, Na+ and endolymphatic sac potential (ESP) resulting from volume injections into, and withdrawals from, scala media of the cochlea. In the present study, we compared the influence of injections into and withdrawals from scala tympani of the cochlea on the endolymphatic sac. It is assumed that similar pressure changes are induced in endolymph and perilymph of both the cochlear and vestibular compartments of the ear. Pressure changes induced by the perilymphatic injections and withdrawals did not induce similar K+ changes in the ES. The majority of perilymph withdrawals caused K+ and ESP reductions in the sac, but few injections caused any measurable changes in the sac. Pressure measurements from the ES demonstrated that transmission of labyrinthine pressures to the lumen was directionally sensitive, with negative pressure transmitted more effectively than positive. In other experiments, application of infrasonic stimulation to the ear canal resulted in K+ increase in the ES. These physiological measurements suggest that the endolymphatic duct may be closed by sustained positive pressure in the vestibule but open during pressure fluctuations. Study of the anatomy where the endolymphatic duct enters the vestibule suggests that the membranous sinus of the endolymphatic duct could act as a mechanical valve, limiting the flow of endolymph from the saccule to the endolymphatic sac when pressure is applied. This structure could therefore play an important role in endolymph volume regulation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 100
页数:11
相关论文
共 50 条
  • [41] Design and research of the one-way microsphere valve and the PDMS film electromagnetic micropump
    Xiaodan Miao
    Hongguang Lu
    He Chen
    Shihai Liu
    Microfluidics and Nanofluidics, 2022, 26
  • [42] The bunged bung - one-way valve malfunction during elective surgery - Reply
    Stamatelos, E.
    ANAESTHESIA AND INTENSIVE CARE, 2008, 36 (06) : 912 - 912
  • [43] Mechanical Hemolysis in Pediatric Patients Associated with Rapid Transfusion and One-Way Valve
    Gniadek, Thomas John
    Richtsfeld, Martina
    Pulkrabek, Shelley
    Fahey-Ahrndt, Kayla R. H.
    Barnett, Susan
    Joyner, Nitasha
    Kinney, Stephanie
    Zantek, Nicole D.
    Azakie, Anthony
    Cohn, Claudia S.
    TRANSFUSION, 2017, 57 : 124A - 125A
  • [44] Design and research of the one-way microsphere valve and the PDMS film electromagnetic micropump
    Miao, Xiaodan
    Lu, Hongguang
    Chen, He
    Liu, Shihai
    MICROFLUIDICS AND NANOFLUIDICS, 2022, 26 (09)
  • [45] CARDIAC ARREST AS A RESULT OF ONE-WAY VALVE TYPE OBSTRUCTION OF THE ENDOTRACHEAL TUBE
    Mahli, Ahmet
    Coskun, Demet
    Ilica, Sibel
    Arpaci, Hande
    Karabiyik, Lale
    GAZI MEDICAL JOURNAL, 2010, 21 (01): : 41 - 43
  • [46] Mechanical hemolysis in pediatric patients associated with rapid transfusion and one-way valve
    Gniadek, Thomas J.
    Richtsfeld, Martina
    Pulkrabek, Shelley
    Hansen, Kayla R.
    Barnett, Susan L.
    Joyner, Nitasha
    Kinney, Stephanie
    Zantek, Nicole D.
    Azakie, Anthony
    Cohn, Claudia S.
    TRANSFUSION, 2018, 58 (05) : 1228 - 1233
  • [47] EVIDENCE FOR ONE-WAY MOVEMENT DETECTION IN VISUAL-SYSTEM OF DROSOPHILA
    GOTZ, KG
    BUCHNER, E
    BIOLOGICAL CYBERNETICS, 1978, 31 (04) : 243 - 248
  • [48] Experimental evidence for spatiotemporal stability and control of a one-way open CML
    Imai, T
    Konishi, K
    Kokame, H
    Hirata, K
    INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 2002, 12 (12): : 2937 - 2944
  • [49] EVIDENCE FOR ONE-WAY VALVES IN WATER-FLOW SYSTEM OF SPONGES
    VOGEL, S
    JOURNAL OF EXPERIMENTAL BIOLOGY, 1978, 76 (OCT): : 137 - 148
  • [50] Analysis of one-way layout of count data in the presence of over or under dispersion
    Saha, Krishna K.