Responses of the endolymphatic sac to perilymphatic injections and withdrawals: evidence for the presence of a one-way valve

被引:45
|
作者
Salt, AN
Rask-Andersen, H
机构
[1] Washington Univ, Sch Med, Dept Otolaryngol, St Louis, MO 63110 USA
[2] Univ Uppsala Hosp, Akad Sjukhuset, Dept Otolaryngol, S-75185 Uppsala, Sweden
关键词
endolymphatic hydrops; endolymphatic sinus; saccule; Meniere's disease;
D O I
10.1016/j.heares.2003.12.018
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Although the endolymphatic sac (ES) is thought to be a primary site for endolymph volume regulation, we have limited knowledge of how it responds to volume and pressure changes. In a prior publication, we demonstrated changes of K+, Na+ and endolymphatic sac potential (ESP) resulting from volume injections into, and withdrawals from, scala media of the cochlea. In the present study, we compared the influence of injections into and withdrawals from scala tympani of the cochlea on the endolymphatic sac. It is assumed that similar pressure changes are induced in endolymph and perilymph of both the cochlear and vestibular compartments of the ear. Pressure changes induced by the perilymphatic injections and withdrawals did not induce similar K+ changes in the ES. The majority of perilymph withdrawals caused K+ and ESP reductions in the sac, but few injections caused any measurable changes in the sac. Pressure measurements from the ES demonstrated that transmission of labyrinthine pressures to the lumen was directionally sensitive, with negative pressure transmitted more effectively than positive. In other experiments, application of infrasonic stimulation to the ear canal resulted in K+ increase in the ES. These physiological measurements suggest that the endolymphatic duct may be closed by sustained positive pressure in the vestibule but open during pressure fluctuations. Study of the anatomy where the endolymphatic duct enters the vestibule suggests that the membranous sinus of the endolymphatic duct could act as a mechanical valve, limiting the flow of endolymph from the saccule to the endolymphatic sac when pressure is applied. This structure could therefore play an important role in endolymph volume regulation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 100
页数:11
相关论文
共 50 条
  • [21] Arthroscopic cystectomy for Baker's cysts with and without one-way valve lesions: incidence of one-way valve lesion, associated pathologies, and clinical outcomes
    Nha, Kyung Wook
    Kim, Seung Joo
    Park, Jong Hun
    Bae, Ji Hoon
    Jang, Ki-Mo
    Kim, Sang-Gyun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (01) : 287 - 294
  • [22] MASS INOCULATIONS WITH THE AID OF ONE-WAY VALVES FOR MULTIPLE INJECTIONS FROM ONE SYRINGE
    GISPEN, R
    INTERNATIONAL ARCHIVES OF ALLERGY AND APPLIED IMMUNOLOGY, 1954, 5 (06): : 452 - 457
  • [23] Fabrication of an autoclavable one-way valve for venting fermentation gases
    Skory, CD
    Wyckoff, HA
    BIOTECHNIQUES, 1997, 22 (01) : 82 - 82
  • [24] ONE-WAY ALL GLASS VALVE FOR HIGH VACUUM SYSTEMS
    BOLL, HJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (12): : 1415 - &
  • [25] An electromagnetically actuated tube type micropump with a one-way valve
    Liu, Bendong
    Zhang, Zhen
    Yang, Jiechao
    Yang, Jiahui
    Li, Desheng
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2018, 56 (01) : 1 - 9
  • [26] Extracorporeal ventriculoatrial shunt with the use of one-way ball valve
    Kubo, S
    Takimoto, H
    Hosoi, K
    Toyota, S
    Takakura, S
    Hayashi, Y
    Ueno, M
    Morisako, T
    Karasawa, J
    Ninaga, H
    Yoshimine, T
    NEUROLOGICAL SURGERY, 2002, 30 (04): : 405 - 409
  • [27] Silicon photonics A chip-scale one-way valve for light
    Ben Yoo, S. J.
    NATURE PHOTONICS, 2009, 3 (02) : 77 - 79
  • [28] One-way Endobronchial Valve Replacement for a Bronchopleural Fistula Due to Tuberculosis
    Aydogan, Mehmet
    Guendogan, Alper
    Ucar, Ergun
    Caylak, Hasan
    Yuecel, Orhan
    Tozkoparan, Ergun
    Guerkoek, Sedat
    Bilgic, Hayati
    CHEST, 2013, 144 (04)
  • [29] c-Jun as a one-way valve at the naive to primed interface
    Li, Dongwei
    Luo, Ling
    Guo, Lin
    Wu, Chuman
    Zhang, Ran
    Peng, Yuling
    Wu, Menghua
    Kuang, Junqi
    Li, Yan
    Zhang, Yudan
    Xie, Jun
    Xie, Wenxiu
    Mao, Rui
    Ma, Gang
    Fu, Xiuling
    Chen, Jiekai
    Hutchins, Andrew P.
    Pei, Duanqing
    CELL AND BIOSCIENCE, 2023, 13 (01):
  • [30] Development of Active Packaging Technology for Kimchi: One-Way Gas Valve
    Jeong S.
    Cho C.H.
    Lee J.-S.
    Lee H.-G.
    Yoo S.
    ACS Symposium Series, 2019, 1303 : 11 - 23