Simultaneous determination of hydroquinone and catechol using a glassy carbon electrode modified with gold nanoparticles, ZnS/NiS@ZnS quantum dots and L-cysteine

被引:31
|
作者
Wang, Yong [1 ]
Qu, Jianhang [2 ]
Li, Shufang [1 ]
Dong, Ying [1 ]
Qu, Jianying [1 ]
机构
[1] Henan Univ, Coll Chem & Chem Engn, Inst Environm & Analyt Sci, Kaifeng 475004, Henan, Peoples R China
[2] Henan Univ Technol, Coll Bioengn, Zhengzhou 450000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; L-Cysteine; Quantumdots; Hydroquinone; Catechol; Electrochemical sensor; Cyclic voltammetry; Differential pulse voltammetry; REDUCED GRAPHENE OXIDE; SENSING PLATFORM; COMPOSITE; NANOCOMPOSITE; SENSOR; RESORCINOL; SAMPLES; LIQUID; FILM; QDS;
D O I
10.1007/s00604-015-1568-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe an electrochemical sensor for simultaneous determination of hydroquinone (HQ) and catechol (CC). A glassy carbon electrode (GCE) was modified with gold nanoparticles, L-cysteine, and ZnS/NiS@ZnS quantum dots using a layer-by-layer technique. The materials were characterized by X-ray diffractometry, field emission scanning electron microscopy, and electrochemical impedance and Fourier transform infrared spectroscopy. Cyclic voltammetry and differential pulse voltammetry revealed this modified GCE to represent a highly sensitive sensor for the simultaneous determination of HQ and CC. The anodic peak current for HQ at a working voltage of 80 mV (vs. Ag/AgCl) is related to its concentration in the 0.1 to 300 mu M range (even in the presence of 0.1 mM of CC). The anodic peak current for CC at a working voltage of 184 mV is related to its concentration in the 0.5 to 400 mu M range (even in the presence of 0.1 mM of HQ). The detection limits (at an S/N ratio of 3) are 24 and 71 nM for HQ and CC, respectively. The modified GCE was successfully applied to the determination of HQ and CC in aqueous solutions and gave satisfactory results.
引用
收藏
页码:2277 / 2283
页数:7
相关论文
共 50 条
  • [41] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [42] Simultaneous determination of hydroquinone and catechol Using poly(p-aminobenzoic acid) modified glassy carbon electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    Journal of Applied Polymer Science, 2009, 113 (05): : 2881 - 2886
  • [43] Simultaneous Determination of Hydroquinone and Catechol Using Poly(p-aminobenzoic acid) Modified Glassy Carbon Electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 113 (05) : 2881 - 2886
  • [44] Simultaneous determination of catechol and hydroquinone using electrospun carbon nanofibers modified electrode
    Guo, Qiaohui
    Huang, Jianshe
    Chen, Puqing
    Liu, Yang
    Hou, Haoqing
    You, Tianyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 163 (01) : 179 - 185
  • [45] Mesoporous Carbon and Ceria Nanoparticles Composite Modified Electrode for the Simultaneous Determination of Hydroquinone and Catechol
    Liu, Dong
    Li, Fan
    Yu, Dezhong
    Yu, Junxia
    Ding, Yigang
    NANOMATERIALS, 2019, 9 (01)
  • [46] Determination of Catechol and Hydroquinone by Using Perilla frutescens Activated Carbon Modified Glassy Carbon Electrode
    Zheng, Meiqin
    Zhu, Jingjing
    Fan, Rongrong
    Wang, Yujie
    Lv, Zhaojun
    Han, Yongming
    Peng, Jun
    Zheng, Xinyu
    Lin, Ruiyu
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2020, 31 (01) : 25 - 32
  • [47] Poly (L-Cysteine) Modified Glassy Carbon Electrode as a Voltammetric Sensor for the Individual and Simultaneous Determination of Serotonin and Tyramine
    Anand, Sanu K.
    Mathew, Manna Rachel
    Girish Kumar, K.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (04)
  • [48] Simultaneous Determination of Hydroquinone, Catechol and Resorcinol Based on Graphene/Cobalt Hexacyanoferrate Modified Glassy Carbon Electrode
    Huang Kejing
    Yu Sheng
    Wang Lan
    Gan Tian
    Li Mei
    ACTA CHIMICA SINICA, 2012, 70 (06) : 735 - 740
  • [49] Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Bai, Junyue
    Wang, Hongjing
    Zhang, Liying
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (01): : 123 - 132
  • [50] A glassy carbon electrode modified with graphene quantum dots and silver nanoparticles for simultaneous determination of guanine and adenine
    Wang, Guoying
    Shi, Gaofeng
    Chen, Xuefu
    Yao, Ruixing
    Chen, Fuwen
    MICROCHIMICA ACTA, 2015, 182 (1-2) : 315 - 322