Radiation dose absorbed by operators during transradial percutaneous coronary procedures comparing different protective drapes: the RADIATION study

被引:12
|
作者
Sciahbasi, Alessandro [1 ]
Rigattieri, Stefano [1 ]
Sarandrea, Alessandro [2 ]
Cera, Maria [1 ]
Di Russo, Cristian [1 ]
Fedele, Silvio [1 ]
Romano, Silvio [3 ]
Pugliese, Francesco Rocco [1 ]
Penco, Maria [3 ]
机构
[1] Sandro Pertini Hosp, Intervent Cardiol & Emergency Dept, Rome, Italy
[2] HSE Management, Rome, Italy
[3] Univ Aquila, Cardiol Dept, Laquila, Italy
关键词
clinical trials; radial; radiation protection; PELVIC LEAD SHIELD; FEMORAL ACCESS; EXPOSURE; INTERVENTIONS; ANGIOGRAPHY; CATHETERIZATION; METAANALYSIS; REDUCTION; PATIENT; TALENT;
D O I
10.4244/EIJ-D-16-00288
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The aim of this study was to compare different radiation protection drapes in terms of radiation dose absorbed by operators during right or left transradial procedures. Methods and results: Patients who underwent transradial coronary procedures were randomised initially into four groups: Group 1 (no drapes), Group 2 (drape on patients arm), Group 3 (pelvic drape), Group 4 (combined ann and pelvic drapes). Subsequently, each group was further randomised to right or left radial access. The primary endpoint was the operator radiation dose at the thorax. A total of 452 procedures were included. The use of drapes was associated with a lower radiation dose compared to no drapes (8.6 mu Sv [4.1-17.9] Group 1, 5.8 mu Sv [3.4-13] Group 2, 3.6 mu Sv [2.1-6.9] Group 3, 3.7 mu Sv [1.9-10.3] Group 4, p<0.001). Among radiation protection drapes groups the radiation dose was significantly lower in Groups 3 and 4 compared to Group 2 (p<0.008). Compared to Group 1, the dose in Group 2 was significantly lower only in right radial procedures (p<0.008) whereas in Groups 3 and 4 the dose was significantly lower in both radial accesses (p<0.008). Conclusions: The use of radiation protection drapes during transradial coronary procedures is associated with a significantly lower radiation dose to operators, with the pelvic drape more effective than the use of a single ann drape.
引用
收藏
页码:E2253 / E2261
页数:9
相关论文
共 50 条
  • [11] Extended Protective Shield Under Table to Reduce Operator Radiation Dose in Percutaneous Coronary Procedures The EXTRA-RAD Study
    Sciahbasi, Alessandro
    Sarandrea, Alessandro
    Rigattieri, Stefano
    Patrizi, Roberto
    Cera, Maria
    Di Russo, Cristian
    Zezza, Luigi
    Fedele, Silvio
    Ferraiuolo, Giuseppe
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (02)
  • [12] Predictors of Increased Radiation Dose During Percutaneous Coronary Intervention
    Mercuri, Mathew
    Xie, Changchun
    Levy, Michael
    Valettas, Nicholas
    Natarajan, Madhu K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (09): : 1241 - 1244
  • [13] Patient Radiation Dose During Bifurcation Percutaneous Coronary Intervention
    Rempakos, Athanasios
    Strepkos, Dimitrios
    Carvalho, Pedro
    Mutlu, Deniz
    Alexandrou, Michaella
    Yildirim, Ufuk
    Khelimskii, Dmitrii
    Krestyaninov, Oleg
    Uluganyan, Mahmut
    Kultursay, Barkin
    Mastrodemos, Olga
    Rangan, Bavana
    Al-Ogaili, Ahmed
    Jalli, Sandeep
    Voudris, Konstantinos
    Burke, M. Nicholas
    Sandoval, Yader
    Brilakis, Emmanouil
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B194 - B194
  • [14] Factors affecting radiation exposure during transradial cardiac catheterisation and percutaneous coronary intervention
    Mantis, C.
    Papadakis, E.
    Anadiotis, A.
    Kafkas, N.
    Patsilinakos, S.
    CLINICAL RADIOLOGY, 2022, 77 (05) : E387 - E393
  • [15] EVALUATION OF A NEW RADIATION PROTECTION TECHNOLOGY (CARDIO-TRAP®) IN TRANSRADIAL PERCUTANEOUS CORONARY INTERVENTION PROCEDURES
    Parikh, Parth
    Patel, Apurva
    Bhatt, Parloop
    Chag, Milan
    Parikh, Roosha
    Chandarana, Anish
    Baxi, Hemang
    Gupta, Satya
    Kapoor, Vipul
    Sankhla, Vineet
    Parikh, Keyur
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1365 - 1365
  • [16] Radiation dose to the paediatric undergoing diagnostic coronary angiography and percutaneous intervention procedures
    Abuzaid, M.
    Abdelrazig, A.
    Sulieman, A.
    Alkhorayef, M.
    Babikir, E.
    Alonazi, B.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [17] Indicators of the maximum radiation dose to the skin during percutaneous coronary intervention in different target vessels
    Chida, Koichi
    Saito, Haruo
    Kagaya, Yutaka
    Kohzuki, Masahiro
    Takai, Yoshihiro
    Takahashi, Shoki
    Yamada, Shogo
    Zuguchi, Masayuki
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (02) : 236 - 241
  • [18] A Comparison of Indirect Radiation Dose Estimates With Directly Measured Radiation Dose for Patients and Operators During Complex Endovascular Procedures
    Panuccio, Giuseppe
    Greenberg, Roy K.
    Wunderle, Kevin
    Mastracci, Tara
    Eagleton, Matthew J.
    Davros, William
    JOURNAL OF VASCULAR SURGERY, 2010, 51 : 6S - 6S
  • [19] Comparison of indirect radiation dose estimates with directly measured radiation dose for patients and operators during complex endovascular procedures
    Panuccio, Giuseppe
    Greenberg, Roy K.
    Wunderle, Kevin
    Mastracci, Tara M.
    Eagleton, Matthew G.
    Davros, William
    JOURNAL OF VASCULAR SURGERY, 2011, 53 (04) : 885 - 894
  • [20] Comparison of radiation dose to operator between transradial and transfemoral coronary angiography with optimised radiation protection: a phantom study
    Liu, Huiliang
    Jin, Zhigeng
    Jing, Limin
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (04) : 412 - 420